Product Overview
The Foxboro CFS10 and CFS20 Mass Flowtubes, when paired with a Model CFT50 or CFT51 Digital Coriolis Mass Flow Transmitter, create a Coriolis Mass Flow and Density Meter. These devices measure true mass flow rate directly using Coriolis acceleration, eliminating the need for external measurements of temperature, pressure, or specific gravity.
Key Features
  • High accuracy: ±0.10% for liquids and ±0.50% for gases.
  • Density accuracy: ±0.0005 g/cc.
  • Wide rangeability over 100:1.
  • Complies with 3-A sanitary standards.
  • Available in various sizes and configurations for different applications.
  • Constructed with welded 304 stainless steel and optional thick-wall nickel alloy.
  • Designed for hazardous area locations with FM, CSA, and ATEX certifications.
Applications and Versatility
The flowmeters are suitable for a wide range of applications, including those with entrained air, non-Newtonian fluids, viscous and abrasive fluids, slurries, and liquefied gases. They are designed for sanitary service, complying with 3-A standards, making them ideal for the food and drug industry.
Performance and Reliability
  • High accuracy at realistic velocities reduces erosion.
  • Immune to external vibrations and entrained air.
  • Low pressure loss and low velocities reduce pumping costs.
  • Advanced CAE technology ensures high reliability with low stress levels and robust construction.
Operating Conditions
  • Process temperature: -200 to +180°C.
  • Process pressure: Refer to specific tables for limits.
  • Ambient temperature: -40 to +85°C.
  • Relative humidity: 5 to 100%.
System Performance
  • Mass flow rate accuracy for liquids: ±0.10% + Zero Instability.
  • Mass flow rate accuracy for gases: ±0.50% + Zero Instability.
  • Process temperature accuracy: ±1°C for -60 to +100°C.
Functional Specifications
  • Process density range: 200 to 3000 kg/m3.
  • Pressure loss and sizing can be determined using FlowExpertPro software.
Physical Specifications
  • Flowtube to transmitter interface includes a terminal for local earth connection and a weatherproof junction box.
  • Tamperproof sealing options available for enhanced security.
Specifications
  • Model Codes: CFS10 and CFS20 series are described with various options for nominal flowtube and flange sizes, wetted materials, and end connections.
  • Materials: Options include AISI Type 316L Stainless Steel and Nickel alloy (equivalent to Hastelloy® C-22).
  • End Connections: Available in ANSI and EN standards with various pressure ratings.
  • Electrical Safety: Certifications include ATEX, CSA, FM, IECEx, EAC, INMETRO, and KOSHA, with specific codes for different hazardous locations.
Optional Selections
  • Bidirectional Flow Calibration and Cryogenic Applications.
  • Calibration options for use with different transmitters (CFT10, CFT15, CFT50, CFT51).
  • Material Certification and Tamperproof sealing options.
Dimensions
  • Detailed nominal dimensions for various flowtube sizes and configurations, including flanged, sanitary, and threaded end flowtubes.
  • Specific installation requirements for 3-A compliant installations.
Cable Specifications
  • PVC and FEP insulated cables are recommended, with specifications for temperature limits and voltage ratings.
  • Various lengths available for ordering.
Ordering Instructions
  • Includes model numbers for flowtubes, cables, and transmitters.
  • Additional requirements such as flow data and junction box extension kits.
Contact Information
For further assistance, contact Schneider Electric Global Customer Support.
See more

Catalog excerpts

Models CFS10 and CFS20 Mass Flowtubes for Standard and 3-A Sanitary Applications-1

Product Specifications Models CFS10 and CFS20 Mass Flowtubes for Standard and 3-A Sanitary Applications j| The Foxboro® CFS10 and CFS20 Mass Flowtubes combine with a Model CFT50 or CFT51 Digital Coriolis Mass Flow Transmitter to form a Foxboro Coriolis Mass Flow and Density Meter. The principle of Coriolis acceleration is used which allows true mass flow rate measurements of fluids to be made directly, without the need for external temperature, pressure, or specific gravity measurements. FEATURES ► Precision system achieved using digital signal processing (DSP) transmitter. ► High system accuracy of ±0.10% of flow rate plus flowtube zero instability (liquids); ±0.50% of flowrate plus flowtube zero instability (gases). ► Density accuracy of ±0.0005 g/cc or better. ► Wide rangeability in excess of 100:1 without sacrificing performance. ► Complies with 3-A sanitary standards. ► The CFS10 single path design ideal for shear sensitive fluids, and in applications requiring positive cleaning; available in 3 to 50 mm (1/8 to 2 in) sizes. The CFS20 is a dual path design and is available in 40 and 80 mm (1 1/2 and 3 in) sizes. ► Welded 304 ss stainless steel enclosure. Hermetically sealed with 70 kPa (10.15 psia) internal pressure. ► Thick-wall nickel alloy (equivalent to Hastelloy® C-22(1)) construction available. ► Weights and Measures Custody Transfer option, per NIST Handbook 44. ► Weights and Measures Industry Canada Approval option. ► Tamperproof Sealing option of terminal block cover provided with Options -T, -D, and -S. ► Patented anti-phase double driver system allows close sensor proximity to inhibit signal distortion, and provides low power consumption per driver. ► Low stress levels maximize mechanical reliability. ► Easy installation with short end-to-end distance. ► Will drain when mounted in vertical orientation with an upward flow. ► Uses tubes essentially of same nominal I.D. as connecting pipe, and with increased wall thickness. ► Designed for FM, CSA, and ATEX hazardous area locations. Applicable agency plate also includes the CE mark. 1. Hastelloy is a registered trademark of Haynes International Inc.

 Open the catalog to page 1
Models CFS10 and CFS20 Mass Flowtubes for Standard and 3-A Sanitary Applications-2

INTRODUCTION This Mass Flow and Density Meter, comprising a CFT51 Mass Flow and Density Transmitter and a CFS10 or CFS20 Mass Flowtube, measures fluid mass flow rate directly, not inferentially. The direct measurement of mass eliminates the inaccuracies of multiple process measurements associated with volumetric flow devices are eliminated. This flowmeter is an advanced generation of mass flow devices using Coriolis principles. It incorporates significant improvements in transmitter and flowtube design, including digital signal processing (DSP), computer modeling, remote communications, automated...

 Open the catalog to page 2
Models CFS10 and CFS20 Mass Flowtubes for Standard and 3-A Sanitary Applications-3

HIGH FLOWTUBE RELIABILITY Assured because of: ► Advanced CAE technology with computer modeling ► Rigid center flowtube body ► Automated orbital welding and brazing ► Low stressed welds and brazed joints ► All welds performed by qualified welders ► Annealed process-wetted welds ► Thick walled tubes ► Tubes in torsion (not bending) with low stress throughout, particularly at welds and brazed joints ► Realistic velocities ► Hydrostatically tested at 1.5 times the rated maximum pressure ► Meets NACE requirements MANY FLOWTUBE CONFIGURATIONS a. T = Threaded F = Flanged (ANSI or EN 1092) S = Sanitary...

 Open the catalog to page 3
Models CFS10 and CFS20 Mass Flowtubes for Standard and 3-A Sanitary Applications-4

PSS 1-2B1 A Page 4 OPERATING CONDITIONS (FLOWTUBE ONLY) a. The -200°C (-328°F) operating limit temperature is achievable when the Cryogenic Service option is selected. See Model Code and Optional Selections section. b. Refer to the Electrical Safety Specifications section for a restriction in ambient temperature with certain electrical certifications. c. Where lagging or heat tracing of flowtube is involved, the case temperature may exceed these limits. d. PVC insulated cable is suitable for ambient temperatures from -20 to +80°C (-4 to +176°F). FEP insulated cable is suitable for ambient temperatures...

 Open the catalog to page 4
Models CFS10 and CFS20 Mass Flowtubes for Standard and 3-A Sanitary Applications-5

The following system performance specifications are for Reference Operating Conditions unless otherwise specified. Refer to PSS 1-2B7 A or PSS 1-2B7 C for Model CFT50 or CFT51 Digital Coriolis Mass Flow Transmitter specifications, respectively. Table 1. Zero Instability a. Density Accuracy is at Reference Operating Conditions. b. May require in situ calibration for maximum accuracy

 Open the catalog to page 5
Models CFS10 and CFS20 Mass Flowtubes for Standard and 3-A Sanitary Applications-6

FUNCTIONAL SPECIFICATIONS Table 2. Mass Flow Rate Ranges Process Temperature/Pressure Limits Process temperature/pressure limits are limited by either the maximum flowtube values or the maximum end connection values, whichever are less. Refer to Table 3 and Table 4. Pressure Loss - FlowExpertPro.com To determine pressure loss or sizing for your application, merely have your process information available and visit the FlowExpertPro.com web site. Process Density Process fluid density ranges from 200 to 3000 kg/m3 (12.5 to 187 lb/ft3); or a specific gravity range of 0.2 to 3. Note that a specific...

 Open the catalog to page 6
Models CFS10 and CFS20 Mass Flowtubes for Standard and 3-A Sanitary Applications-7

PSS 1-2B1 A Page 7 Table 4. Flowtube Process Temperature and Pressure Limits with Flanged End Connections (a) a. Linear interpolation is acceptable. b. See Model Codes for flowtube configurations available with 316 ss, 316L ss, and nickel alloy (equivalent to Hastelloy® C-22) end connections. e. If higher MWPs are required, contact Global Customer Support.

 Open the catalog to page 7
Models CFS10 and CFS20 Mass Flowtubes for Standard and 3-A Sanitary Applications-8

PHYSICAL SPECIFICATIONS Flowtube to Transmitter Interface The flowtube has a terminal for the local earth (ground) connection. For signal connections, the flowtube is provided with an integrally mounted electrical junction box that meets the weatherproof rating of IP66/67 as defined by IEC 60529, and provides the environmental and corrosion resistant rating of NEMA Type 4X. The junction box contains a pair of 6-position feedthrough type terminal blocks. The terminal blocks are connected to the flowtube through a hermetic seal with properly spaced intrinsically safe wiring. An internally threaded...

 Open the catalog to page 8
Models CFS10 and CFS20 Mass Flowtubes for Standard and 3-A Sanitary Applications-9

Junction Box Extension Kit for Steam Jacket or Flowtube Insulation The normal clearance between the outside surface of the tube and junction box is a nominal 12.7 mm (1/2 in). In order to adequately accommodate a steam jacket or insulation enveloping the tube’s outside surface, this clearance can be increased to 102 mm (4 in) by using the junction box extension kit shown in Figure 2. See applicable installation instructions and parts list for further details. AISI Type 304 stainless steel (304 ss) with a matte finish. Seams are welded and the enclosure is free from water and dust retaining cavities. Ingress...