1. Catalogs
  2. Schneider Electric
  3. Model MAG2IC Intelligent Magnetic Flowmeter with Integrally Mounted Transmitter, Model MAG2RT Remote Mounted Intelligent Transmitter, and Model MAG2RS Remote Mounted Flowtube

Model MAG2IC Intelligent Magnetic Flowmeter with Integrally Mounted Transmitter, Model MAG2RT Remote Mounted Intelligent Transmitter, and Model MAG2RS Remote Mounted Flowtube

Model MAG2IC Intelligent Magnetic Flowmeter with Integrally Mounted Transmitter, Model MAG2RT Remote Mounted Intelligent Transmitter, and Model MAG2RS Remote Mounted Flowtube
1 / 36 PagesView full catalog

Model MAG2IC Intelligent Magnetic Flowmeter with Integrally Mounted Transmitter, Model MAG2RT Remote Mounted Intelligent Transmitter, and Model MAG2RS Remote Mounted Flowtube

Product catalog summary
Product Overview: The Foxboro® MAG2 Series Flowmeters are advanced magnetic flowmeters designed for high performance and low power consumption. They offer flexibility with integrally mounted or remote configurations suitable for various installation needs.
Key Features:
  • Field-proven, loop-powered, 2-wire operation with high accuracy of ±0.5% of rate.
  • Minimum measurable fluid conductivity of 10 μS/cm.
  • Electrode status diagnostics for empty pipe detection and scaling.
  • Adjustable low flow cutoff and 4 to 20 mA DC analog output with HART communications.
  • FlowExpertPro™ sizing program for optimal flowmeter selection.
  • Available in flanged and wafer body flowtubes with various line sizes and flange ratings.
  • Approved for use in hazardous areas with IP67 and NEMA 4X enclosure ratings.
Performance Specifications:
  • High accuracy and stable output with a minimum fluid conductivity of 10 μS/cm.
  • Remote transmitter options for inaccessible locations with cable lengths up to 70 m.
  • Wide range of flowtube sizes and applications, including corrosive liquids and wastewater.
Operating Conditions:
  • Ambient temperature limits: -20 to +60°C (-4 to +140°F).
  • Ambient relative humidity limits: 10 to 90% RH.
  • Process temperature and pressure ranges detailed in figures.
Functional Specifications:
  • Power supply requirements: 15.6 to 42 V DC without communication, 21.05 to 42 V DC with HART communicator.
  • Output signals include analog, pulse, and contact outputs with adjustable damping.
  • Electrode status diagnostics for detecting empty pipes or scaling.
Physical Specifications:
  • Available in various sizes and materials, including stainless steel and carbon steel.
  • Enclosure materials and finishes designed for corrosion resistance.
  • Approximate weights provided for different models and configurations.
Installation Information:
  • Wiring connections available in multiple thread types.
  • Remote transmitter mounting options include surface mounting with provided brackets and hardware.
Installation and Mounting: The document outlines the installation procedures for Foxboro hardware, specifically focusing on pipe-mounted transmitters. Brackets and U-bolts are provided for attaching the transmitter to a nominal DN 50 or 2-inch pipe. Users must provide their own hardware for bolting brackets to surfaces.
Grounding: Grounding is crucial for accurate flow measurement. The document recommends connecting directly to earth ground with minimal impedance, ensuring less than 1 Ohm to earth for intrinsic safety compliance as per FM and CSA Electrical Safety Code 1. Reference is made to ANSI/ISA RP12.06.01 for installation guidance.
Weight Specifications: The document provides a table listing the approximate weights of various nominal line sizes with different flange classes (ANSI and DIN). For example, a 50 mm (2 in) line size weighs approximately 10.5 kg (23.1 lb) with ANSI Class 150 flanges.
Pipe Connection and Length Requirements: For proper installation, a minimum straight pipe length of 5 diameters is required upstream, increasing to 10 diameters if a diffuser, valve, or pump is present. Downstream, a length of 2 diameters is recommended.
Cable and Terminal Connections: The document specifies cable lengths between remote transmitters and flowtubes, with a maximum of 70 m (233 ft) for larger sizes and 30 m (98 ft) for smaller sizes. Terminal connections are detailed with figures illustrating MAG2IC, MAG2RT, and MAG2RS terminals.
Electrical Safety Specifications: Models MAG2IC, MAG2RT, and MAG2RS are certified for various safety standards, including CSA and FM, with classifications for different divisions and groups. Operating temperature ranges are specified as -20 to +60°C.
Model Codes: The document provides detailed model codes for different configurations of magnetic flowmeters and transmitters, including options for flowtube lining materials, electrode materials, and wiring connections. Calibration and output signal options are also specified.
Dimensions: Nominal dimensions for various flowmeter sizes are provided, including specific details for flanged body flowtubes. Additional notes on grounding ring dimensions are included.
See more

Catalog excerpts

Model MAG2IC Intelligent Magnetic Flowmeter with Integrally Mounted Transmitter, Model MAG2RT Remote Mounted Intelligent Transmitter, and Model MAG2RS Remote Mounted Flowtube-1

Product Specifications Model MAG2IC Intelligent Magnetic Flowmeter with Integrally Mounted Transmitter, Model MAG2RT Remote Mounted Intelligent Transmitter, and Model MAG2RS Remote Mounted Flowtube The Foxboro® brand MAG2 Series Flowmeters are high performance, intelligent Magnetic Flowmeters based on field proven two-wire, loop powered technology. They offer the stable and accurate measurement of a traditional magnetic flowmeter with low power consumption, resulting in a lower overall cost of ownership. The flowmeters are provided in an integrally mounted transmitter configuration, or with a remote transmitter and flowtube with an interconnecting cable. FEATURES ► Field proven, loop powered, 2-wire operation. ► High accuracy to ±0.5% of rate. ► Minimum measurable fluid conductivity down to 10 |±S/cm. ► Suitable for use in numerous process fluid measurement industries. ► Electrode status diagnostic (determines empty pipe detection, or scaling on electrode). ► Adjustable low flow cutoff. ► 4 to 20 mA dc Analog Output with HART Communications. ► FlowExpertPro™ sizing program; see next page. ► Flanged body flowtubes are offered in 2.5 to 200 mm (0.1 to 8 in) line sizes when integrally mounted, and in 10 to 200 mm (1 to 4 in) line sizes when remote mounted. ► Wafer body flowtubes are offered in 25 to 100 mm (1 to 4 in) line sizes when either integrally or remote mounted. ► Flowtubes used with ANSI Class 150 or 300 flanges, or DN PN10, PN16, or PN25 flanges. ► Standard mounting brackets and hardware for surface or pipe mounting of the remote transmitte

 Open the catalog to page 1
Model MAG2IC Intelligent Magnetic Flowmeter with Integrally Mounted Transmitter, Model MAG2RT Remote Mounted Intelligent Transmitter, and Model MAG2RS Remote Mounted Flowtube-2

► Interconnecting cable for remote configurations offered in numerous lengths up to 70 m (233 ft), depending on line size. ► Approved/Certified by many agencies for use in hazardous area locations. ► Enclosure meets IEC IP67 and NEMA 4X ratings. HIGH ACCURACY AND STABLE OUTPUT MAG2 provides a high accuracy of ± 0.5% of rate. MINIMUM MEASURABLE FLUID CONDUCTIVITY MAG2 offers a minimum process fluid conductivity of 10 p.S/cm, which is excellent when compared to other 2-wire magnetic flowmeters, thereby maximizing applicability. LOW FLOW CUTOFF, DROPOUT, AND EMPTY PIPE DETECTION Refer to the Functional...

 Open the catalog to page 2
Model MAG2IC Intelligent Magnetic Flowmeter with Integrally Mounted Transmitter, Model MAG2RT Remote Mounted Intelligent Transmitter, and Model MAG2RS Remote Mounted Flowtube-3

OPERATING CONDITIONS  Incorporates a large library of the physical properties of typical process fluids.  Displays results in tabular or graphic format.  Allows user to save, print, or E-mail results.  Provides reference to applicable flowmeter PSSs and other related flowmeter documentation. The program calculates minimum and maximum flow rates, rangeability, pressure loss, and Reynolds Number, using established flow equations. It also allows for material and flange selection. You are invited to visit www.FlowExpertPro.com to access this program, or contact Global Customer Support (see last...

 Open the catalog to page 3
Model MAG2IC Intelligent Magnetic Flowmeter with Integrally Mounted Transmitter, Model MAG2RT Remote Mounted Intelligent Transmitter, and Model MAG2RS Remote Mounted Flowtube-4

PERFORMANCE SPECIFICATIONS PSS 1-6G3 A Page 4 Figure 2. Nominal Line Sizes 15 to 200 mm (1/2 to 8 in) Process Temperature/Process Pressure Ranges PERFORMANCE SPECIFICATIONS Analog Output Accuracy Nominal Line Sizes: 2.5 and 5 mm (0.1 and 0.2 in) Nominal Line Size 25 to 200 mm (1 to 8 in)

 Open the catalog to page 4
Model MAG2IC Intelligent Magnetic Flowmeter with Integrally Mounted Transmitter, Model MAG2RT Remote Mounted Intelligent Transmitter, and Model MAG2RS Remote Mounted Flowtube-5

PERFORMANCE SPECIFICATIONS Lightning Protection Equipped with a lightning arrester in the power source and external output terminals; it can withstand a transient surge of 12 kV, 1000 A without permanent damage. Power Failure An EEPROM retains data record of totalized value when pulse output is used (retention period approximately 10 years). Measurable Electrical Conductivity INTEGRAL TRANSMITTER VERSIONS 10 p.S/cm, or greater REMOTE TRANSMITTER VERSIONS ► Nominal Line Sizes 10 and 15 mm (3/8 and 1/2 in), 50 p.S, or greater ► Nominal Line Sizes 25 to 200 mm (1 to 8 in), 10 p.S, or greater. Measurement...

 Open the catalog to page 5
Model MAG2IC Intelligent Magnetic Flowmeter with Integrally Mounted Transmitter, Model MAG2RT Remote Mounted Intelligent Transmitter, and Model MAG2RS Remote Mounted Flowtube-6

FUNCTIONAL SPECIFICATIONS Power Supply (see Figure 3) Figure 3. 4 to 20 mA Output Supply Voltage vs. Output Load WITHOUT COMMUNICATION WITH AN OUTPUT LOAD OF 250  WHEN USING A HART COMMUNICATOR CURRENT CAPACITY Inrush Current: 24 mA Steady State Current: 22 mA Output Signal Analog output Open Collector Output: 30 V dc, 100 mA maximum Pulse Frequency: 0.0001 to 200 Hz Pulse Width: 1 ms to 1 s. Voltage Drop: 2.5 V maximum Contact output Open collector output (30 V dc, 100 mA maximum) Pulse or contact output is selectable Flow Units Volume flow m³, L, cm³, G (gallon), mG, kG, B (barrel), IG (imperial...

 Open the catalog to page 6
Model MAG2IC Intelligent Magnetic Flowmeter with Integrally Mounted Transmitter, Model MAG2RT Remote Mounted Intelligent Transmitter, and Model MAG2RS Remote Mounted Flowtube-7

PHYSICAL SPECIFICATIONS Electrode Status Diagnostic The Electrode Status Diagnostic (in most applications) can be used to determine if the pipe is empty, or if there is scaling on the electrodes. These are detected by monitoring the flow rate signal. Once the flow rate signal fluctuates over a certain threshold, the device judges that the tube is empty, or there is scaling on the electrodes. When the tube is empty, or there is scaling on the electrodes, the analog 4 to 20 mA output and pulse output are set to zero flow values. The display alternately shows zero value, empty, or scale on electrode. There...

 Open the catalog to page 7
Model MAG2IC Intelligent Magnetic Flowmeter with Integrally Mounted Transmitter, Model MAG2RT Remote Mounted Intelligent Transmitter, and Model MAG2RS Remote Mounted Flowtube-8

PHYSICAL SPECIFICATIONS Terminal Box Finish (Model MAG2RS only) Standard Baked acrylic paint Corrosion RESISTANT Baked epoxy paint Display Cover Material Tempered glass Flowtube Body Materials Case material Sizes 2.5 to 15 mm (0.1 to 1/2 inch): CF8M ss Sizes 25 to 200 mm (1 to 8 inches): 304 ss Measuring pipe material 304 ss Flange Material SIZES 2.5 to 65 mm (0.1 to 2 1/2 in) 304 stainless steel SIZES 80 to 200 mm (3 to 8 in) Carbon steel with a corrosion resistant paint. Process Wetted Materials Lining PFA Electrodes 316L ss, ASTM B574 (Hastelloy C-276 equivalent), Titanium, Tantalum, Nickel...

 Open the catalog to page 8
Model MAG2IC Intelligent Magnetic Flowmeter with Integrally Mounted Transmitter, Model MAG2RT Remote Mounted Intelligent Transmitter, and Model MAG2RS Remote Mounted Flowtube-9

Approximate Weight: Model MAG2IC Flowmeter with Transmitter Integrally Mounted to Wafer Body Flowtube Nominal Line Size a. For Flowtubes with Standard Face-to-Face dimension.

 Open the catalog to page 9
Model MAG2IC Intelligent Magnetic Flowmeter with Integrally Mounted Transmitter, Model MAG2RT Remote Mounted Intelligent Transmitter, and Model MAG2RS Remote Mounted Flowtube-10

INSTALLATION INFORMATION Approximate Weight: Model MAG2RS Flanged Body Magnetic Flowtubes (Transmitter is Remote) INSTALLATION Wiring Connection ► 1/2 NPT internal thread (not available with ATEX Electrical Safety Codes 3 and 4) ► M20 internal thread ► G 1/2 internal thread Remote Transmitter Mounting SURFACE MOUNTED TRANSMITTER Three brackets and hardware are provided and attach to the transmitter with Foxboro hardware. The brackets are then bolted to surface with hardware provided by user. PIPE MOUNTED TRANSMITTER Bracket, U-bolt, and hardware provided for attaching transmitter to bracket,...

 Open the catalog to page 10
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.