1. Catalogs
  2. Schneider Electric
  3. Circuit protection and control devices 0.5 to 6300A

Circuit protection and control devices 0.5 to 6300A

Circuit protection and control devices 0.5 to 6300A
1 / 72 PagesView full catalog

Circuit protection and control devices 0.5 to 6300A

Product catalog summary
Overview: The document provides comprehensive specifications and guidelines for Schneider Electric's low voltage circuit protection and control devices, covering a range from 0.5 to 6300 A. It includes technical data, installation standards, and coordination tables for efficient electrical installations.
Specifications: Detailed characteristics of circuit breakers and switch-disconnectors, including Multi 9, NG160, Compact NSX, and Masterpact series, are outlined. Key specifications include rated current, insulation voltage, impulse withstand voltage, and breaking capacities.
Procedures: Installation guidelines emphasize easy installation in modular switchboards and compatibility with Pragma or Prisma Plus enclosures. Connection methods and dimensions for various devices are also covered.
Standards and Norms: Products comply with international standards such as IEC 60947-2 and IEC 60898, ensuring reliability and safety. Coordination between circuit breakers and switch-disconnectors is highlighted to protect against short-circuits and overloads.
Recommendations: The guide recommends using the LV protection coordination guide to optimize protection and connection device choices, enhancing supply continuity. Technical booklets and coordination tables are suggested as reference tools for high-performance electrical design.
Key Data from Tables: Tables provide detailed electrical characteristics for each product, including rated currents, breaking capacities, and endurance cycles. Selection guides for choosing appropriate circuit breakers and switch-disconnectors based on specific installation requirements are included.
Protection Features: Overcurrent protection includes long-time, short-time, and instantaneous settings. Earth-fault and residual earth-leakage protection are available in specific models, with Zone Selective Interlocking (ZSI) enhancing device coordination.
Installation and Connectivity: Connection types include fixed, plug-in, and withdrawable options. Dimensions and weight vary by model, with auxiliary features like remote communication and advanced protection settings.
Durability and Standards: Mechanical and electrical durability is rated for up to 10,000 mechanical operations and 5,000 electrical operations at full load, complying with IEC 60947-1/2 and EN 60947-1/2 standards.
Additional Features: Advanced protection includes remote operation and transmission of settings. Switch-disconnector characteristics are detailed for specific models, with rated making and breaking capacities.
Control Units: Micrologic control units provide protection and measurement functions, including current, voltage, frequency, and power quality measurements, managed by microprocessors.
Source-Changeover Systems: Manual and automatic source-changeover systems are described, including interlocking methods and the use of automatic controllers for remote-operated systems.
See more

Catalog excerpts

Circuit protection and control devices 0.5 to 6300A-1

Electrical distribution Circuit protection and control devices 0.5 to 6300 A LV product characteristics 2009 LVPED208013EN_couv.indd 1 04/12/2008 13:54:03

 Open the catalog to page 1
Circuit protection and control devices 0.5 to 6300A-2

This international site allows you to access all the Schneider Electric products in just 2 clicks via comprehensive range data- sheets, with direct links to: • complete library: technical documents, catalogs, FAQs, • selection guides from • product discovery sites and their Flash animations. You will also find illustrated overviews, news to which you can subscribe, the list of country These technical guides help you comply with installation standards installation guide, the protection implementation guide, and the co-ordination tables all form genuine reference tools for the design of high performance...

 Open the catalog to page 2
Circuit protection and control devices 0.5 to 6300A-3

General contents Multi 9 A-2 Multi 9 circuit breakers from 0.5 to 125 A NG160 A-2 A-4 Characteristics of NG160 circuit breakers and switch-disconnectors Incomer for modular switchboards Easypact A-4 A-4 A-6 Selection table EZC circuit breakers A-6 A-6 Compact NSX A-10 Characteristics and performance of Compact NSX circuit breakers from 100 to 630 A Compact NS A-10 A-12 Protection of distribution systems Compact NS circuit breakers up to 630 A Compact NS circuit breakers from 630 up to 3200 A A-12 A-12 A-14 Compact NS -Direct Current A-16 DC circuit breakers characteristics Compact NS100 to NS630...

 Open the catalog to page 3
Circuit protection and control devices 0.5 to 6300A-4

Multi 9 Multi 9 circuit breakers from 0.5 to 125 A 056984NR_14 Multi 9 circuit breaker DPN N Vigi Number of poles 1+N Electrical characteristics DPN Vigi Rated current (A) In Rated insulation voltage (V) Ui Impulse withstand voltage (kV) Uimp Maximum operational voltage (V) Ue AC 50/60 Hz Fast closing Suitability for isolation and positive contact indication 4-40 400 4 230 b b AC breaking capacity PB100270_16 IEC 60898 (EN 60898) IEC 60947-2 (EN 60947-2) Icn (A) Icu (kA) 6 - B (lm = 3 to 5 ln) C (lm = 5 to 10 ln) D (lm = 10 to 14 ln) K (lm = 10 to 14 In) Z (lm = 2.4 to 3.2) MA (lm = 12 ln) Ics...

 Open the catalog to page 4
Circuit protection and control devices 0.5 to 6300A-6

NG160 Characteristics of NG160 circuit breakers and switch-disconnectors Incomer for modular switchboards 3 and 4 pole circuit breakers and switch-disconnectors specially designed for use upstream of Multi 9 modular devices: b reinforcement of breaking capacities of downstream devices by cascading up to 25 kA b easy installation in Pragma or Prisma Plus type G enclosures: v standard 45 mm front cut-out v clip-on installation on a DIN rail v reduced depth (82.5 mm). NG160 circuit breaker Electrical characteristics as per IEC 60947-2 Rated current (A) Rated insulation voltage (V) Rated impulse...

 Open the catalog to page 6
Circuit protection and control devices 0.5 to 6300A-7

NG160 Characteristics of NG160 circuit breakers and switch-disconnectors Incomer for modular switchboards PB103530-58 Installation and connections Connections Connectors Bare cables from 1.5 to 70 mm² cables Dimensions (mm) WxHxD NG160 NG160 with Vigi Weight (kg) Device Device + Vigi module 3P 4P 3P 4P 90 x 120 x 82.5 120 x 120 x 82.5 210 x 120 x 82.5 240 x 120 x 82.5 3P 4P 3P 4P Width in 9 mm modules 10 14 24 27 1.1 1.4 2.6 2.9 NG160 in modular enclosure. A-5 LVPED208013EN.indd 5 04/12/2008 13:55:38

 Open the catalog to page 7
Circuit protection and control devices 0.5 to 6300A-8

Easypact Selection table EZC circuit breakers PB101838-10 EasyPact circuit breakers Number of poles Rated current (A) Rated insulation voltage (V) Rated impulse withstand voltage (kV) Rated operational voltage (V) EZC100-1P. In Ui Uimp Ue AC 50/60 Hz DC Electrical characteristics as per IEC 60947-2, EN 60947-2, JIS C8201-2-1 Icu Rated service breaking capacity (kA rms) Ics PB101840-15 Ultimate breaking capacity (kA rms) EZC100-2P. at 40 °C Suitability for isolation Utilisation category Pollution degree Endurance (C-O cycles) AC 50/60 Hz 110/130 V 220/230/240 V 380 V 400/415 V 440 V 550 V DC 125...

 Open the catalog to page 8
Circuit protection and control devices 0.5 to 6300A-10

Easypact Selection table EZC circuit breakers PB101852-32 EasyPact circuit breakers Number of poles Rated current (A) In Rated insulation voltage (V) Ui Rated impulse withstand voltage (kV) Uimp Rated operational voltage (V) Ue at 40°C AC 50/60 Hz DC Electrical characteristics as per IEC 60947-2, EN 60947-2 and JIS C8201-2-1/C8201-2-2 Ultimate breaking capacity (kA rms) Icu Rated service breaking capacity (kA rms) Suitability for isolation Utilisation category Pollution degree Endurance (C-O cycles) Ics AC 50/60 Hz 220/230/240 V 380 V 400/415 V 440 V 550 V DC 125 V (1P) 250 V (2P...

 Open the catalog to page 10
Circuit protection and control devices 0.5 to 6300A-12

Compact NSX Characteristics and performance of Compact NSX circuit breakers from 100 to 630 A PB103354-40 Common characteristics Rated voltages Insulation voltage (V) Ui 800 Impulse withstand voltage (kV) Uimp 8 Operational voltage (V) Ue AC 50/60 Hz 690 IEC/EN 60947-2 Suitability for isolation yes Utilisation category A Pollution degree IEC 60664-1 3 Circuit breakers Breaking capacity levels Electrical characteristics as per IEC 60947-2 Rated current (A) 40 °C lcu AC 50/60 Hz 220/240 V 380/415 V 440 V 500 V 525 V 660/690 V lcs AC 50/60 Hz 220/240 V 380/415 V 440 V 500 V 525 V 660/690 V Mechanical...

 Open the catalog to page 12
Circuit protection and control devices 0.5 to 6300A-14

Compact NS Protection of distribution systems PB101050_33 Compact NS circuit breakers up to 630 A Compact circuit breakers Number of poles Control manual Connections electric fixed plug-in (on base) withdrawable (on chassis) PB101044_42 Compact NS250H Compact NS630N toggle direct or extended rotary handle front connection rear connection front connection rear connection front connection rear connection Electrical characteristics as per IEC 60947-2 and EN 60947-2 Rated current (A) In 40 °C 65 °C Rated insulation voltage (V) Ui Rated impulse withstand voltage (kV) Uimp Rated operational voltage...

 Open the catalog to page 14
Circuit protection and control devices 0.5 to 6300A-16

Compact NS Protection of distribution systems DB112530 Compact NS circuit breakers from 630 up to 3200 A Compact circuit breakers Number of poles Control manual toggle direct or extended rotary handle electric Type of circuit breaker Connections fixed E45178R_68 Compact NS800L Compact NS2000H front connection rear connection front connection with bare cables withdrawable (on chassis) front connection rear connection Electrical characteristics as per IEC 60947-2 and EN 60947-2 Rated current (A) In 50 °C 65 °C (1) Rated insulation voltage (V) Ui Rated impulse withstand voltage (kV) Uimp Rated operational...

 Open the catalog to page 16

All Schneider Electric catalogs and technical brochures

  1. CFT34A

    2  Pages

  2. IMT30A

    2  Pages

  3. 15607

    2  Pages

  4. IMV25

    2  Pages

  5. RM6 Catalogue

    76  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.