Model MAG2IC Intelligent Magnetic Flowmeter with Integrally Mounted Transmitter, Model MAG2RT Remote Mounted Intelligent Transmitter, and Model MAG2RS Remote Mounted Flowtube - 1

Product Specifications Model MAG2IC Intelligent Magnetic Flowmeter with Integrally Mounted Transmitter, Model MAG2RT Remote Mounted Intelligent Transmitter, and Model MAG2RS Remote Mounted Flowtube The Foxboro® brand MAG2 Series Flowmeters are high performance, intelligent Magnetic Flowmeters based on field proven two-wire, loop powered technology. They offer the stable and accurate measurement of a traditional magnetic flowmeter with low power consumption, resulting in a lower overall cost of ownership. The flowmeters are provided in an integrally mounted transmitter configuration, or with a remote transmitter and flowtube with an interconnecting cable. FEATURES ► Field proven, loop powered, 2-wire operation. ► High accuracy to ±0.5% of rate. ► Minimum measurable fluid conductivity down to 10 |±S/cm. ► Suitable for use in numerous process fluid measurement industries. ► Electrode status diagnostic (determines empty pipe detection, or scaling on electrode). ► Adjustable low flow cutoff. ► 4 to 20 mA dc Analog Output with HART Communications. ► FlowExpertPro™ sizing program; see next page. ► Flanged body flowtubes are offered in 2.5 to 200 mm (0.1 to 8 in) line sizes when integrally mounted, and in 10 to 200 mm (1 to 4 in) line sizes when remote mounted. ► Wafer body flowtubes are offered in 25 to 100 mm (1 to 4 in) line sizes when either integrally or remote mounted. ► Flowtubes used with ANSI Class 150 or 300 flanges, or DN PN10, PN16, or PN25 flanges. ► Standard mounting brackets and hardware for surface or pipe mounting of the remote transmitte

Open the catalog to page 1
Model MAG2IC Intelligent Magnetic Flowmeter with Integrally Mounted Transmitter, Model MAG2RT Remote Mounted Intelligent Transmitter, and Model MAG2RS Remote Mounted Flowtube - 2

► Interconnecting cable for remote configurations offered in numerous lengths up to 70 m (233 ft), depending on line size. ► Approved/Certified by many agencies for use in hazardous area locations. ► Enclosure meets IEC IP67 and NEMA 4X ratings. HIGH ACCURACY AND STABLE OUTPUT MAG2 provides a high accuracy of ± 0.5% of rate. MINIMUM MEASURABLE FLUID CONDUCTIVITY MAG2 offers a minimum process fluid conductivity of 10 p.S/cm, which is excellent when compared to other 2-wire magnetic flowmeters, thereby maximizing applicability. LOW FLOW CUTOFF, DROPOUT, AND EMPTY PIPE DETECTION Refer to the...

Open the catalog to page 2
Model MAG2IC Intelligent Magnetic Flowmeter with Integrally Mounted Transmitter, Model MAG2RT Remote Mounted Intelligent Transmitter, and Model MAG2RS Remote Mounted Flowtube - 3

OPERATING CONDITIONS  Incorporates a large library of the physical properties of typical process fluids.  Displays results in tabular or graphic format.  Allows user to save, print, or E-mail results.  Provides reference to applicable flowmeter PSSs and other related flowmeter documentation. The program calculates minimum and maximum flow rates, rangeability, pressure loss, and Reynolds Number, using established flow equations. It also allows for material and flange selection. You are invited to visit www.FlowExpertPro.com to access this program, or contact Global Customer Support (see...

Open the catalog to page 3
Model MAG2IC Intelligent Magnetic Flowmeter with Integrally Mounted Transmitter, Model MAG2RT Remote Mounted Intelligent Transmitter, and Model MAG2RS Remote Mounted Flowtube - 4

PERFORMANCE SPECIFICATIONS PSS 1-6G3 A Page 4 Figure 2. Nominal Line Sizes 15 to 200 mm (1/2 to 8 in) Process Temperature/Process Pressure Ranges PERFORMANCE SPECIFICATIONS Analog Output Accuracy Nominal Line Sizes: 2.5 and 5 mm (0.1 and 0.2 in) Nominal Line Size 25 to 200 mm (1 to 8 in)

Open the catalog to page 4
Model MAG2IC Intelligent Magnetic Flowmeter with Integrally Mounted Transmitter, Model MAG2RT Remote Mounted Intelligent Transmitter, and Model MAG2RS Remote Mounted Flowtube - 5

PERFORMANCE SPECIFICATIONS Lightning Protection Equipped with a lightning arrester in the power source and external output terminals; it can withstand a transient surge of 12 kV, 1000 A without permanent damage. Power Failure An EEPROM retains data record of totalized value when pulse output is used (retention period approximately 10 years). Measurable Electrical Conductivity INTEGRAL TRANSMITTER VERSIONS 10 p.S/cm, or greater REMOTE TRANSMITTER VERSIONS ► Nominal Line Sizes 10 and 15 mm (3/8 and 1/2 in), 50 p.S, or greater ► Nominal Line Sizes 25 to 200 mm (1 to 8 in), 10 p.S, or...

Open the catalog to page 5
Model MAG2IC Intelligent Magnetic Flowmeter with Integrally Mounted Transmitter, Model MAG2RT Remote Mounted Intelligent Transmitter, and Model MAG2RS Remote Mounted Flowtube - 6

FUNCTIONAL SPECIFICATIONS Power Supply (see Figure 3) Figure 3. 4 to 20 mA Output Supply Voltage vs. Output Load WITHOUT COMMUNICATION WITH AN OUTPUT LOAD OF 250  WHEN USING A HART COMMUNICATOR CURRENT CAPACITY Inrush Current: 24 mA Steady State Current: 22 mA Output Signal Analog output Open Collector Output: 30 V dc, 100 mA maximum Pulse Frequency: 0.0001 to 200 Hz Pulse Width: 1 ms to 1 s. Voltage Drop: 2.5 V maximum Contact output Open collector output (30 V dc, 100 mA maximum) Pulse or contact output is selectable Flow Units Volume flow m³, L, cm³, G (gallon), mG, kG, B (barrel), IG...

Open the catalog to page 6
Model MAG2IC Intelligent Magnetic Flowmeter with Integrally Mounted Transmitter, Model MAG2RT Remote Mounted Intelligent Transmitter, and Model MAG2RS Remote Mounted Flowtube - 7

PHYSICAL SPECIFICATIONS Electrode Status Diagnostic The Electrode Status Diagnostic (in most applications) can be used to determine if the pipe is empty, or if there is scaling on the electrodes. These are detected by monitoring the flow rate signal. Once the flow rate signal fluctuates over a certain threshold, the device judges that the tube is empty, or there is scaling on the electrodes. When the tube is empty, or there is scaling on the electrodes, the analog 4 to 20 mA output and pulse output are set to zero flow values. The display alternately shows zero value, empty, or scale...

Open the catalog to page 7
Model MAG2IC Intelligent Magnetic Flowmeter with Integrally Mounted Transmitter, Model MAG2RT Remote Mounted Intelligent Transmitter, and Model MAG2RS Remote Mounted Flowtube - 8

PHYSICAL SPECIFICATIONS Terminal Box Finish (Model MAG2RS only) Standard Baked acrylic paint Corrosion RESISTANT Baked epoxy paint Display Cover Material Tempered glass Flowtube Body Materials Case material Sizes 2.5 to 15 mm (0.1 to 1/2 inch): CF8M ss Sizes 25 to 200 mm (1 to 8 inches): 304 ss Measuring pipe material 304 ss Flange Material SIZES 2.5 to 65 mm (0.1 to 2 1/2 in) 304 stainless steel SIZES 80 to 200 mm (3 to 8 in) Carbon steel with a corrosion resistant paint. Process Wetted Materials Lining PFA Electrodes 316L ss, ASTM B574 (Hastelloy C-276 equivalent), Titanium, Tantalum,...

Open the catalog to page 8
Model MAG2IC Intelligent Magnetic Flowmeter with Integrally Mounted Transmitter, Model MAG2RT Remote Mounted Intelligent Transmitter, and Model MAG2RS Remote Mounted Flowtube - 9

Approximate Weight: Model MAG2IC Flowmeter with Transmitter Integrally Mounted to Wafer Body Flowtube Nominal Line Size a. For Flowtubes with Standard Face-to-Face dimension.