Autofilt Z

Autofilt Z

Autofilt Z

Product catalog summary
Overview: The document provides technical specifications and features of the Singlebeam Colorimeter and the AutoFilt Z Automatic Pressure Filtration Unit, both products of SCHMIDT+HAENSCH GmbH & Co.
Singlebeam Colorimeter:
  • Equipped with three fixed wavelengths: 420, 560, and 720 mm, and an additional optional wavelength.
  • Compatible with polarimeter cells up to 100 mm.
  • Designed for ICUMSA color measurement of liquid sugar.
  • Programmable for other methods.
AutoFilt Z Automatic Pressure Filtration Unit:
  • Provides fast and efficient sample filtration, suitable for laboratory use.
  • Features sensor-controlled operation for consistent filtrate volume.
  • Automatically discards pre- and post-filtrate fractions to ensure high-quality samples.
  • Environmentally friendly, avoiding the use of hazardous chemicals.
  • Technical specifications include operating temperature range of +10 to +40°C, power supply requirements, and adjustable filtration pressure up to 5 bar.
Applications: The AutoFilt Z is intended for use in environmentally sensitive laboratories, particularly for the preparation of samples for NIR-Polarimeters.
Company Information: SCHMIDT+HAENSCH GmbH & Co. is based in Berlin, Germany, and has been producing opto-electronic measuring devices since 1864.
See more

Catalog excerpts

Autofilt Z-1

Automatic Pressure Filtration Unit Einstrahl-Colorimeter zur Farbmessung Fastest sample filtration for lab use. Filtration units are a complement to NIR-Polarimeters. Z allows easy and • 3 feste Wellenlängen: 420,AutoFilt 560 und 720 mm fast filtration of turbid and high coloured samples. • Eine frei wählbare Wellenlänge The filtration time is shortened drastically, resulting in more • Verwendung von Polarimeterröhren bis 100 mm efficient and reliable quality control. Samples are prepared • ICUMSA Farbmessung von Flüssigkeit without using environmentally hazardous clarification • Weitere Methoden programmierbar chemicals. The new generation of AutoFilt Z is even more user friendly and guarantees an absolutely safe and stable analysis. The advanced sensor and processor based system is discarding pre- and post-filtrate fractions and provides a high quality filtrate. First filtrate portion which can contain suspended matter and particles is discarded as well as the third filtration portion often accompanied with foam which is developed during the last phase of the filtration. Resulting high quality filtrate features constant sample volumes independent of the operator, sample viscosity and turbidity. Singlebeam-colorimeter for colour measurements • 3 fixed wavelight 420, 560, 720 mm • One optional wavelight • Polarimeter cells up to 100 mm usable • ICUMSA color measurement of liquid sugar • Other methods programmable Software controlled drop collector for clean bench Applications AutoFilt Z is mainly intended for use in modern, environmental sensitive laboratories. Precise adjustable air pressure for optimization of the filtration process and drain hose for drop collection Filtrated probe Polarimeter or Saccharomat® + Refractometer Head SW Measuring results of purity, Brix and °Z SCHMIDT+HAENSCH GmbH & Co. Waldstraße 80/81 D-13403 Berlin Germany Phone: +49 30 / 41 70 72-0 Fax: +49 30 / 41 70 72-99 e-mail: [email protected] www.schmidt-haensch.com www.schmidt-haensch.eu SCHMIDT + HAENSCH Opto-electronic measuring device since 1864 Subject to modification without notice SCHMIDT+HAENSCH reserved all rights over texts and images Änderungen vorbehalten Subject to modification without notice 05/10 01/03 Technical Data Environmental conditions Temperature: +10 up to +40°C (50 - 104°F) Supply: Power Supply: 100 - 240 VAC ,47 - 63 Hz, 40 W Pressurized air: Max. 10 bar - 1.0 MPa / oil-free Pressurized air tube: Outer diameter 6 mm Waste water tube: Inner diameter 16 mm Filtration Filtration pres. adjustable: Max. 5 bar - 0.5 MPa Probe volume: Approx. 250 ml Sample vol

 Open the catalog to page 1
Autofilt Z-2

Coloromat Autofilt Z Coloromat Automatic Pressure Filtration Unit • Einstrahl-Colorimeter Fast filtration, automaticallyzur adjusted to sample characteristicsSinglebeam-colorimeter for colour measurements Farbmessung • Sensor controlled operation ensuring constant filtrate volume 3 feste Wellenlängen: 720 mm for high quality • •Automated discarding of420, pre-560 andund post-filtrate • 3 samples fixed wavelight 420, 560, 720 mm • Eine frei wählbare Wellenlänge • One optional wavelight • Environment-friendly preparation perfect for NIR-Polarimeters • Verwendung von Polarimeterröhren bis 100 mm...

 Open the catalog to page 2

All SCHMIDT + HAENSCH catalogs and technical brochures