video corpo cad

Installation systems for safe series connection
20Pages

{{requestButtons}}

Catalog excerpts

Installation systems for safe series connection - 1

Safety in system: Protection vor man and machine INSTALLATION SYSTEMS FOR SAFE SERIES CONNECTION

Open the catalog to page 1
Installation systems for safe series connection - 2

Heinz and Philip Schmersal, Managing Directors of the Schmersal Group Optimum safety solutions for your production processes Based on the world‘s largest programme of safety switchgear, the Schmersal Group develops safety systems and safety solutions tailored to individual requirements. After all, it is not just about safeguarding individual machines but complex plant systems. Having flexibility in production is becoming an increasingly important factor in today‘s production: The batch sizes are becoming smaller and there needs to be a fast and simple way to adapt the machines to changing...

Open the catalog to page 2
Installation systems for safe series connection - 3

Description of safety installation systems______________________________________ Page Introduction______________________________________________________________ Page Overview_________________________________________________________________ Page PDM-IOP – passive distribution modules for parallel IO wiring____________________ PDM-SD – passive distribution modules for SD interface_________________________ PFB-IOP – passive fieldboxes for parallel IO wiring______________________________ PFB-SD – passive fieldboxes for SD interface___________________________________ SRB-E-PE – active input...

Open the catalog to page 3
Installation systems for safe series connection - 4

DESCRIPTION OF SAFETY INSTALLATION SYSTEMS INTRODUCTION Schmersal safety installation systems Schmersal safety installation systems are installation aids for fast, simple and thereby low cost wiring of safety switchgear in series. The solutions are divided into two areas: passive distributors and fieldboxes for the connection of electronic safety switchgear as well as active input expander modules for the connection of safety switches and safety sensors with contact outputs or as electronic versions. The passive distributors for installation in switching cabinets or terminal boxes and the...

Open the catalog to page 4
Installation systems for safe series connection - 5

Schmersal SD-Interface The "Series Diagnostic" interface is used for transferring non-safe data where electronic safety switchgear is connected in series. Safety sensors and interlocks that feature the SD interface can transfer extensive diagnostic data from the individual devices with series-wiring via the SD gateway and a field bus to a control system. Interlocks with series-wiring can also be locked or unlocked individually via the SD interface. There are additional control functions on some interlocks from Schmersal, such as the latching force adjustment on the MZM 100-SD. A mixed...

Open the catalog to page 5
Installation systems for safe series connection - 6

DESCRIPTION OF SAFETY INSTALLATION SYSTEMS OVERVIEW Passive distribution modules PDM ■ Installation in a switching cabinet or in terminal boxes ■ Mixed series connection possible of 1– 4 electronic safety sensors or solenoid interlocks ■ Several modules can be switched in series for more comprehensive safety functions ■ Individual protection of safety switchgear for every device connection with auto-reset fuses ■ Can be configured easily via DIP switches ■ Individual diagnosis and actuation of connected safety switchgear ■ Wiring via spring-type terminals suitable for 0.25 – 1.5 mm² / 10 A...

Open the catalog to page 6
Installation systems for safe series connection - 7

Active input expander modules SRB-E ■ Installation in a switching cabinet or in terminal boxes ■ Mixed series connection possible of 1– 4 safety switches or safety sensors with contact outputs or OSSD outputs ■ Several modules can be switched in series for more comprehensive safety functions ■ Active electronic evaluation of connected safety switchgear ■ Safety level of cat. 4 / PL e / SIL 3 for series connection of switches and sensors with contact outputs ■ Different contact configurations of switches and sensors can be selected ■ Function settings can be configured easily via rotary...

Open the catalog to page 7
Installation systems for safe series connection - 8

PDM-IOP PASSIVE DISTRIBUTION MODULES FOR PARALLEL IO WIRING Product advantages PDM-IOP-4CC-IOP ■ Easy and low cost installation for electronic safety switchgear ■ 1– 4 safety sensors or solenoid interlocks can be connected, mixed connection also possible ■ Device is connected via 4 x 8-pin 4-layer spring-type terminal ■ Simple configuration of number of devices via DIP switches ■ iagnosis signals from safety switchgear can be evaluated individually, solenoid interlocks can be actuated individually D ■ Direct and simple series connection of modules possible ■ 10 A power supply to modules...

Open the catalog to page 8
Installation systems for safe series connection - 9

Example layout of PDM-IOP with Schmersal safety switchgear Type Module to module wire *Depends on number of devices

Open the catalog to page 9
Installation systems for safe series connection - 10

PDM-SD PASSIVE DISTRIBUTION MODULES FOR SD-INTERFACE Product advantages of PDM-SD-4CC-SD ■ Easy and low cost installation for electronic safety switchgear ■ 1– 4 safety sensors or solenoid interlocks can be connected, mixed connection also possible ■ Device is connected via 4 x 8-pin 4-layer spring-type terminal ■ Simple configuration of number of devices via DIP switches ■ Individual evaluation via SD interface of diagnostic signals from safety switchgear, solenoid interlocks can be actuated individually ■ Direct and simple series connection of modules possible ■ 10 A power supply to...

Open the catalog to page 10
Installation systems for safe series connection - 11

Example layout of PDM-SD with Schmersal safety switchgear Type Module to module wire *Depends on number of devices

Open the catalog to page 11
Installation systems for safe series connection - 12

PFB-IOP PASSIVE FIELDBOXES FOR PARALLEL IO WIRING Product advantages of PFB-IOP-4M12-IOP ■ Simple and low cost plug & play field installation for electronic safety switchgear from Schmersal ■ 1– 4 safety sensors or solenoid interlocks can be connected, mixed connection also possible ■ Device connected via 8-pin M12 connector ■ Simple configuration of number of devices via DIP switches behind screw-on protective cover ■ ndividual evaluation of diagnostic signals from safety switchgear, solenoid interlocks can be actuated individually I ■ Direct and simple series connection of boxes in field...

Open the catalog to page 12
Installation systems for safe series connection - 13

Example layout of PFB-IOP with Schmersal safety switchgear Type *Depends on number of devices

Open the catalog to page 13
Installation systems for safe series connection - 14

PFB-SD PASSIVE FIELDBOXES FOR SD-INTERFACE Product advantages of PFB-SD-4M12-SD ■ Simple and low cost plug & play field installation for electronic safety switchgear from Schmersal ■ 1– 4 safety sensors or solenoid interlocks can be connected, mixed connection also possible ■ Device connected via 8-pin M12 connector ■ Simple configuration of number of devices via DIP switches behind screw-on protective cover ■ Individual evaluation via SD interface of diagnostic signals from safety switchgear, solenoid interlocks can be actuated individually ■ Direct and simple series connection of boxes in...