GLP1-g Safety, function and high-voltage testers Expect more. Safety and function testers
Open the catalog to page 1The GLP1-g – Innovative, versatile, compact Thanks to SCHLEICH’s advanced test technology, all kinds of electrical and electronic products can be inspected with the single or multi tester GLP1-g. More than 50 GLP1-g-variants promise perfect solutions for various testing tasks and your individual requirements. In accordance with our corporate philosophy, almost all of the hardware and software is developed and produced at our facilities in Germany. SCHLEICH’s innovations raise the bar in the modern testing of high-voltage, safety and device functionality. Single or multi tester Safety and function...
Open the catalog to page 2Application fields Laboratory | manual testing The GLP1-g is ready for immediate use to perform your measurements. In manual mode, any test method integrated in the tester can be started immediately. Preparations of test sequences are not necessary. You can directly select the desired test method, and start testing. Similar to a multimeter, the display always indicates the current measured values. Your DUT (Device Under Test) is evaluated in all details and with instant feedback. Also long-run analyses, lasting for hours, can also be performed within this operation mode. Production | semi-automated...
Open the catalog to page 3Standard equipment Made in Germany • USB service interface on the front panel • RS232, USB and LAN automation interface • 6 x 24 V DC inputs/control inputs • 7 x 24 V DC output/signal output • RS232, USB or LAN communication with SCHLEICH PC-software PrintComG2 • RS232 or USB communication with SCHLEICH PC-software PrintCom7 • Communication with third-party software possible • Communication via LabView-Driver • Dual circuit safety inputs according to EN50191 • Warning light connection • Result light connection • Safety and warning messages • Key switch at test testers without safety current limiting...
Open the catalog to page 4The GLP1-g high-voltage testers serve for testing the insulation capability and the dielectric strength of electric components or assemblies. These testers are perfectly suitable for fast and simple tests during repair or production. The tests can be performed either manually using safety test pistols, or automatically. The tester provides the programming of time sequences, other monitoring functions or the detection of insulation faults by "burning". The high voltage is generated electronically. The manual voltage setting is accomplished by activating the rotary button on the front panel of...
Open the catalog to page 5Testing – everything at a glance Perfectly optimized for your work process Clearly arranged and informative Efficiently testing and working The GLP1-g provides you a complete and clear overview of all relevant measured values. The clear presentation of test results enables an organized and efficient work process. This facilitates later analyses of the different tests. PE/GB-resistance tester During testing, the display indicates the measured values, the test current and the test time. Insulation resistance tester High-voltage tester Multi tester With multi testers, all test steps are listed one...
Open the catalog to page 6The menu – simply intuitive For optimal working, a high-quality display with precise user guidance is essential. Therefore, the GLP1-g is equipped with a multi-function TFT color display. With its high contrast and wide viewing angle, all necessary information is clearly displayed – this is true both of dark environments or if there is bright sunlight. By activating the menu button on the touch screen you can change between the different menu options. By means of the red marked line, the parameter to be adjusted can be selected. The button “edit” has to be activated to enable any changes. In...
Open the catalog to page 7Technical data High-voltage testers PE/GB-resistance testers Article number resistance test resistance test resistance test resistance test resistance test Insulation resistance tester IR 1000: Insulation resistance test max. 1000 V DC HVAC 6/3: HVAC 6/100: HVAC 6/200: HVAC 12/100: HVAC 15/50: HVAC 30/30: HVAC 50/25: • Standard configuration O Extras — Not available > Please find more high-voltage testers under: www.schleich.com/en/highvoltagetest *for test pistols with push button in the test probe tip SCHLE1CH B Advanced Test Technologies
Open the catalog to page 8Technical data Safety testers Article number • Standard configuration O Extras — Not available + Required for tests without protective device SCHLE1CH B Advanced Test Technologies GB 10AC: PE/GB-resistance test 10 A AC GB 30AC: PE/GB-resistance test 30 A AC IR 1000: Insulation resistance test max. 1000 V DC IR 4000: Insulation resistance test max. 4000 V IR 6000: Insulation resistance test max. 6000 V IR 10000: Insulation resistance test max. 10000 V HVAC 6/3: High-voltage test AC 50-6000 V, 3 mA, safety current limiting HVAC 6/20: High-voltage test AC 50-6000 V, 20 mA HVAC 6/100: High-voltage...
Open the catalog to page 9Technical data Safety and function testers • Standard configuration O Extras — Not available + Required for tests without protective device IR 1000: Insulation resistance test max. 1000 V DC, 3 mA, safety current limiting HVAC 6/3: High-voltage test AC 50-6000 V, 3 mA, safety current limiting HVAC 6/100: High-voltage test AC 50-6000 V, 100 mA HVDC 4/10: High-voltage test DC 50-4000 V, 10 mA
Open the catalog to page 10Technical data The PE/GB-resistance test is performed with electronically controlled, stabilized test current. By measuring the voltage drop and the current the tester calculates the PE/GB- resistance. The PE/GB resistance must not exceed the maximum resistance defined within the standards. The operator contacts the DUT’s (Device Under Test) PE/GB-connections one after another with a test probe. The insulation is tested with electronically controlled, stable high voltage. During the test, the current must not exceed a defined maximum value. In case the current exceeds this default value the test...
Open the catalog to page 1131 Pages
8 Pages
15 Pages
13 Pages
1 Page
8 Pages
1 Page
1 Page