Overview: The GLP1-e HV high-voltage testing devices are designed for testing the insulation capability and electric strength of electrical modules and components. They are suitable for both manual and automatic testing within production processes.
Specifications:- AC high-voltage testers up to 30KV and DC high-voltage testers up to 6KV with minimal residual ripple.
- Three operational modes: manual, automatic with target time, and burning mode.
- Automatic voltage adjustment with ramp and high-voltage check/cable-break detection.
- Acoustic error messages and optical indications via signal lamps on the front panel.
- Interfaces for printer, remote control, or result transmission, including RS232 and digital I/O.
- Available in table-top unit, mobile caddy, and 19” installation designs.
Procedures: The devices allow for manual testing via test pistols and automatic testing with programmed time targets. They also support the localization of isolation faults through a 'burning' process.
Integration and Control: The testers can be integrated into automatic production lines and controlled remotely via PC, PLC, or LabView®. Digital I/O channels facilitate this integration.
Additional Features:- Combination testers with internal automatic switch-over between different test methods for complex testing tasks.
- High-voltage cables and contactings available for automatic production lines or test systems.
- PrintCom software for storing and printing test results.
Applications: Ideal for OEM applications and integration into automatic lines with remote control capabilities.
Testing Capabilities:- Single tester AC high-voltage: 3KV to 50KV with varying current capacities.
- Single tester DC high-voltage: 1KV to 6KV with varying current capacities.
- Combination tester high-voltage: 6KV AC, 3KV AC, 2.5KV DC with insulation resistance and PE resistance options.
Accessories and References: The document references various accessories such as HV pistols, warning lamps, mains-connection adapters, contacting devices, test covers, rolling tables, and calibration boxes.