EXTERNAL PROTECTION SCHIRTEC E.S.E. LIGHTNING CONDUCTORS SCHIRTEC E.S.E. Lightning Conductors protect large fields from one point by becoming active with the lightning risk by increasing the atmospheric electric field effect during thunderstorms. The head of E.S.E. Lightning Conductors is divided into four main parts: 1. Air Terminal 2. Ion Generator 3. Accelerator and Atmospheric Electrodes 4. Grounding Connection Terminal Figure1. Details of SCHIRTEC E.S.E. Lightning Conductor If you calculate Level-II according to appendix B of the NF C 17-102 For D=30 m, L=60 m, h=6m, from Eq.1, Rp=87 m...

Open the catalog to page 2
LIGHTNING PROTECTION SYSTEMS SURGE PROTECTION DEVICES EARTHING MATERIALS 2014-2015 - 3

E.S.E. SCHIRTEC LIGHTNING CONDUCTORS Model Protection Radius Tested Protection Radius )T (µs) Size (cm) Weight (kg) Material Stainless steel * PREMIUM Models with second ion generator for additional safety

Open the catalog to page 3
LIGHTNING PROTECTION SYSTEMS SURGE PROTECTION DEVICES EARTHING MATERIALS 2014-2015 - 4

SCHIRTEC E.S.E. LIGHTNING CONDUCTORS TESTED

Open the catalog to page 4
LIGHTNING PROTECTION SYSTEMS SURGE PROTECTION DEVICES EARTHING MATERIALS 2014-2015 - 5

SCHIRTEC CERTIFICATES & TEST REPORTS

Open the catalog to page 5
LIGHTNING PROTECTION SYSTEMS SURGE PROTECTION DEVICES EARTHING MATERIALS 2014-2015 - 6

SOLAR TESTER SRC-1T All SCHIRTEC E.S.E. Lightning Conductors can be tested any time by utilizing the respective tester. The Tester indicates OK (green LED) or FAULT (red LED). There are two different types of testers available. The solar tester works remotely. The testing device stores energy to operate for 24 hours by an exposition of 5-7 hours of sun light daily. 1. The Testing Device is installed at a 45 degree angle to the pole facing south. 2. The Testing Device is connected through a cable with the E.S.E. Lightning Conductor. 3. The Testing Device has to be switched ON. 4. A test has...

Open the catalog to page 6
LIGHTNING PROTECTION SYSTEMS SURGE PROTECTION DEVICES EARTHING MATERIALS 2014-2015 - 7

Exothermic Welding SCHIRTEC Exothermic welding is a process to join materials permanently with the conductors. Exothermic welding is usually used for welding copper conductors but it is suitable for a wide range of metals. Product Packaging SCHIRTEC Exotermic Welding Powder is available in cartridges with the following content: The lack of an external heat source and the benefit of joining materials permanently within seconds are one of the advantages of Exothermic Welding. The Exothermic Welding has an excellent corrosion resistance and does not suffer from increased electrical resistance...

Open the catalog to page 7
LIGHTNING PROTECTION SYSTEMS SURGE PROTECTION DEVICES EARTHING MATERIALS 2014-2015 - 8

SA-1T (SCHIRTEC LIGHTNING CONDUCTOR TESTER) The SCHIRTEC Lightning Conductors can be checked by this Tester every time.The Tester will indicate OK or FAULT with the help of red or green LED. Ref.No: SA-1T Description SCHIRTEC Tester SLSC-10 (SCHIRTEC LIGHTNING STRIKE COUNTER) Ref.No: SLSC-10 Description SCHIRTEC Lightning Strike Counter Description The Lightning Strikes will be detected and recorded by the SLSC-10. This device can also show the intact operation of the Lightning System. Why Should We Use a Lightning Counter? By using an inductive record, the counter is able accurately to...

Open the catalog to page 8
LIGHTNING PROTECTION SYSTEMS SURGE PROTECTION DEVICES EARTHING MATERIALS 2014-2015 - 9

SLB (SCHIRTEC LED BEACON) Properties, Special designed red glass cover. Aluminium frame. Anti-static protection covered circuit. Produced according to IP 65 (certified by TGM Laboratory) The SCHIRTEC LED BEACON is covered by a red coloured glass and especially manufactured to show a maximum light distribution. 1 The SCHIRTEC LED BEACONs frame is manufactured by an injection aluminium technology. Upon it, a special kit is mounted in order to facilitate the montage. For the security purpose, the red glass cover is connected with a slim steel wire (minimum 30 cm) to the aluminium frame firmly....

Open the catalog to page 9
LIGHTNING PROTECTION SYSTEMS SURGE PROTECTION DEVICES EARTHING MATERIALS 2014-2015 - 10

E.S.E. LIGHTNING CONDUCTORS & PRODUCTS 5 2 E.S.E. Lightning Conductors Tester 2 1 Lightning Strike Counter 2 12 5 SCHIRTEC LED Beacon 5 6 Mast Clamp 6 7 Mast Clip 7 8 Plastic Holders for Isolated Floor/Roofs 8 1 Plastic, Concrete Inspection Pits 6 16 9 Plastic Holders for Isolated Walls 9 1 Earthing Rod Clamps and Exothermic Welding 5 15 1 SCHIRTEC Earthing Enhancement Material 7 17

Open the catalog to page 10
LIGHTNING PROTECTION SYSTEMS SURGE PROTECTION DEVICES EARTHING MATERIALS 2014-2015 - 11

INTERNAL PROTECTION SURGE PROTECTION DEVICES POWER SUPPLY SYSTEMS LIGHTNING ARRESTER CLASS I S45 = Encapsulated power spark gap Iimp= 60kA (L/N) , UN=230V/50Hz, Imax = 100 kA, Up 2,5 kV S50-50 = Encapsulated power spark gap Iimp= 50kA(L/N), UN=230V/50Hz, Imax = 110 kA, Up 1,3 kV S55 = Encapsulated power spark gap Iimp= 60kA (L/N) , UN=230V/50Hz, Imax = 100 kA, Up 4 kV S50-3 = Encapsulated power spark gap Iimp= 50kA (L/N) , UN=230V/50Hz, Imax = 110 kA, Up 1,3 kV S100 = Encapsulated power spark gap Iimp= 120kA (N/PE),Uc=255V/50Hz,Imax = 160kA,Up 2 kV SB 120 = Lightning arrester class I. 85kA...

Open the catalog to page 11
LIGHTNING PROTECTION SYSTEMS SURGE PROTECTION DEVICES EARTHING MATERIALS 2014-2015 - 12

Lightning arrester class I Iimp = 7 kA (10/350) Uc= 385 V AC Imax=50 kA Up < 1,5 kV Lightning arrester class I Iimp = 7 kA (10/350) dist. sig. Uc= 385 V AC Imax=50 kA Up<1,5 kV Lightning arrester class I Iimp = 7 kA (10/350) Uc= 440 V AC Imax=50 kA Up < 1,7 kV Lightning arrester class I Iimp = 7 kA (10/350) dist. sig. Uc= 440 V AC Imax=50 kA Up<1,7 kV Lightning arrester class I Iimp = 12,5 kA (10/350) Uc= 275 V AC Imax=100 kA Up < 1,2 kV Lightning arrester class I Iimp = 12,5 kA (10/350) dist. sig. Uc= 275 V AC Imax=100 kA Up<1,2 kV Lightning arrester class I Iimp = 12,5 kA (10/350) Uc= 320...

Open the catalog to page 12
LIGHTNING PROTECTION SYSTEMS SURGE PROTECTION DEVICES EARTHING MATERIALS 2014-2015 - 13

POWER SUPPLY SYSTEMS LIGHTNING ARRESTER CLASS II Surge arrester 20kA (8/20) Surge arrester 20kA (8/20) Surge arrester 20kA (8/20) Surge arrester 20kA (8/20) Surge arrester 20kA (8/20) + sig. Surge arrester 20kA (8/20) + sig. Surge arrester 20kA (8/20) + sig. Surge arrester 20kA (8/20) + sig. Surge arrester 15kA (8/20) Surge arrester 15kA (8/20) Surge arrester 15kA (8/20) + sig. Surge arrester 15kA (8/20) + sig. Surge arrester 15kA (8/20) Surge arrester 20kA (8/20) Surge arrester 20kA (8/20) = Surge arrester 15kA (8/20) = Surge arrester 15kA (8/20) + sig. = Surge arrester 20kA (8/20) + sig....

Open the catalog to page 13
LIGHTNING PROTECTION SYSTEMS SURGE PROTECTION DEVICES EARTHING MATERIALS 2014-2015 - 14

COMPUTER NETWORK PROTECTION Module for PC systems for 5 cat Module for PC systems for 5 cat Module for PC systems for 5 cat Module for PC systems for 5 cat SPSK 10 SPSK 2/100M - 5 cat SPSK 4/100M - 5 cat SPSK 24 Metal box Module for 2 pairs Module for 4 pairs Metal box SCHIRTECNET 8. RJ/RJ SCHIRTECNET 8.*XC/RJ SCHIRTECTEL 8.1 RJ/RJ SCHIRTECTEL 8.2 RJ/RJ SCHIRTECTEL 8.1 LSA/RJ SCHIRTECTEL 8.2 LSA/RJ Module for 8 stations, input and output RJ 45 Module for 8 stations, input XC and output RJ 45 Module for 8 stations, input and output RJ 45 Module for 8 stations, input and output RJ 45 Module...