Standard pull in range (p.i.) Environmental conditions^^^^^^^^^^^^^^^^^H All data are for unmodified reed switches measured using standard test coil with 10 000 turns, wire diameter 0.06mm and coil resistance 1600 Q. Dimensions (mm) SCHALTTECHNIK Changeover Reed Switch JRC-20 / ORC-20 Form C Switch Excellent reliability and life expectancy • Original JanusReedContact • Contact material Rh • 20W, 1A changeover switch • Filled with inert gas • Gold-plated leads • Actuation by permanent magnet or electromagnet • Tight hysteresis possible • AT range from 10 to 55 possible Application: • Measurement systems • Proximity sensors • Position detection • Fluid level sensing, etc. Handling and modification: Reed switch must be protected while handling, cutting, bending, mounting, encapsulating, welding, soldering etc.. During modification, care must be taken not to apply excessive mechanical force that could result in hermetic seal damage. Recommended distance from end of glass capsule for lead bending and cutting is no less than 1,2mm. We can offer crop and form customisation to your specification. Ordering: Packaging factor = 200pcs AT ranges and modification on your choice and based on your drawings.