Connect - Contact - Control Contactors CH1130/02 Series Single pole high-voltage contactor up to 3 kV Catalogue C170.en More information at: schaltbau-gmbh.com

Open the catalog to page 1
Brochure en - 2

CH1130/02 Single pole high-voltage contactor for DC and AC CH Series – Compact HV contactor in new design Schaltbau has introduced an update of its CH Series high-voltage contactors which have proven their worth in industrial and railway applications for decades. Its completely modernized design is comparable to the one of the most successful CT series. The new CH1130/02 also uses permanent magnets and ceramic elements for quenching the electric arc, thus ensuring optimal functionality and reliability of the contactor. The customer is now offered a new version for 3 kV DC and AC with...

Open the catalog to page 2
Brochure en - 3

CH1130/02 Dimension and circuit diagram Terminal Main contact M6 screw Torque 8 Nm max. Terminal Main contact M6 screw Torque 8 Nm max. Coil terminal WAGO 264 Visual inspection of main contacts Push both clips apart and pull out segment of arc chute positioned in the inspection area to make room for a visual inspection of the main contacts. Auxiliary switch block 2x S826 or S926 Inspection area Earthing stud M6 screw Torque 8 Nm max. 272 Subject to change / Dimensions in mm

Open the catalog to page 3
Brochure en - 4

Terminal Main contacts Mounting 4x M6 screw Torque 5 Nm max. Terminal Main contacts Maintenance and safety instructions Safety instructions: ●● CH1130/02 Series contactors are maintenance free with normal use. ●● Make regular inspections once or twice a year. So when installing the contactor, make sure that there is enough space to take out and re-assemble the segment of the arc chute with ease, so that the main contacts become accessible for inspection. ●● Visual inspection of main contacts: For visual inscpection of the main contacts there is an opening in the arc chute. Push both clips...

Open the catalog to page 4
Brochure en - 5

Specifications Series Type of voltage Contact configuration Nominal voltage Un Rated operating voltage Ue Rated insulation voltage UNm Rated impulse withstand voltage UNi Pollution degree / Overvoltage category Switching surges  Ue = 3,600 V Conventional thermal current Ith   at wire gauge Component category (IEC 60077-2) Short-circuit making capacity Breaking capacity (T2 = 15 ms)   DC, Ue = 1,200 V   DC, Ue = 1,800 V   DC, Ue = 3,600 V Breaking capacity (T2 = 1 ms)   DC, Ue = 1,200 V   DC, Ue = 1,800 V   DC, Ue = 3,600 V Breaking capacity, reverse current direction (T2 < 1 ms)   DC, Ue...

Open the catalog to page 5
Brochure en - 6

Schaltbau GmbH with compliments: For detailed information on our products and services visit our website – or give us a call! Schaltbau GmbH Hollerithstrasse 5 81829 Munich Germany Schaltbau GmbH manufactures in compliance with RoHS. The production facilities of Schaltbau GmbH have been IRIS certified since 2008. Certified to DIN EN ISO 14001 since 2002. For the most recent certificate visit our website. Certified to DIN EN ISO 9001 since 1994. For the most recent certificate visit our website. Electrical Components and Systems for Railway Engineering and Industrial Applications Connectors...

Open the catalog to page 6

All Schaltbau GmbH catalogs and technical brochures

  1. Flyer C320

    8 Pages

  2. UIC-IT Series

    12 Pages

  3. Brochure

    8 Pages

  4. Connectors

    7 Pages

  5. LV Series

    12 Pages

  6. SB Series

    8 Pages

  7. GA Series

    10 Pages

  8. G, GM series

    44 Pages

  9. S880 Series

    12 Pages