The Solution: SCAT Europe Level Control Systems
12Pages

{{requestButtons}}

Catalog excerpts

The Solution: SCAT Europe Level Control Systems - 1

I‘VE GOT THIS UNDER CONTROL. Overflowing Containers Harmful and Dangerous! The Solution: SCAT Europe Level Control Systems. www.scat-europe.com SCAT level controls warn of overflowing or empty containers with a visual and acoustic signal. In addition, peripheral devices such as pumps and valves can be controlled via contact switches

Open the catalog to page 1
The Solution: SCAT Europe Level Control Systems - 2

HPLC-Disposal Safety Funnels Safe Monitoring of Fill and Empty Levels ✔ Electronic or Mechanical ✔ Manually Calibratable Alarms ✔ Level Control Level Control Containers Accessory Adden

Open the catalog to page 2
The Solution: SCAT Europe Level Control Systems - 3

Level Control Level Control against Overflow and Emptiness Whether overfilling or emptiness - both do harm and disrupt the processes in everyday laboratory work. The level control developed by SCAT warns of critical fill levels with an optical and acoustic signal. In addition, peripheral devices such as pumps and valves can be controlled via contact switches.

Open the catalog to page 3
The Solution: SCAT Europe Level Control Systems - 4

Level Control You know This? Comparison HPLC-Supply Overflowing canister without level control. HPLC-Disposal Safety Funnels Level Control Hermetically sealed containers with fill or empty sensors. Containers Accessory Addendum

Open the catalog to page 4
The Solution: SCAT Europe Level Control Systems - 5

Level Control Sensors for Fill Level States SCAT sensors detect liquids through glass or plastic, without contact with the contents of the container. Simply attach at the desired height - In conjunction with a SCAT signal box, you receive an optical and acoustic warning when a critical fill level is reached. Available as a fill level or empty level sensor. Easy Mounting ⹅ Suitable for all commercially available containers made of glass or non-conductive plastic Fill or empty state Sensors for fill and empty level state available. ⹅ Transmits signal to electronic signal boxes, see page 124...

Open the catalog to page 5
The Solution: SCAT Europe Level Control Systems - 6

Level Control Sensors for Fill Level States 108 048 HPLC-Disposal Safety Funnels Looking for the right container? Canisters, bottles and other containers, suitable with the SCAT Level Control Sensors starting from page 130. Disc sensor, alarm at full state Disc sensor, alarm at empty state Stainless steel Active: PTFE Capacitive disc sensor Output function: NAMUR, operating distance 1 - 10 mm adjustable Switch amplifier necessary (108 278) Capacitive sensor for leakage control Output function: NAMUR, operating distance 0.5 - 3 mm adjustable Switch amplifier necessary (108 278) Capacitive...

Open the catalog to page 6
The Solution: SCAT Europe Level Control Systems - 7

Level Control Signal Boxes for Level Control Our signal boxes always warn you in time with visual and acoustic signals before the determined fill level of your collection containers reaches the critical level. This prevents from unseen overflowing of your containers. Compatible with all SCAT level control sensors. The alarm can be silenced during the exchange of the container. Electronic Signal Boxes T1 and T5 Further informations More informations about signal boxes can be found in our SymLine® system catalogue. Visit our website www.symline.de and go to the downloads section. You can find...

Open the catalog to page 7
The Solution: SCAT Europe Level Control Systems - 8

Level Control Signal Boxes for Level Control Safety Funnels Level Control Table display for Built-in Signalbox2, wall thickness: 2 mm Stainless steel, brushed Mount for Built-in Signalbox2, wall thickness: 2 mm Stainless steel, brushed Front panel for Built-in Signalbox , wall thickness: 2 mm Stainless steel, brushed

Open the catalog to page 8
The Solution: SCAT Europe Level Control Systems - 9

Level Control Level Control Disc Sensor Sets The complete solution against spilling containers. The sensor detects liquids through glass or plastic, without contact with the contents of the container. Simply attach at the desired height - you receive an optical and acoustic warning when a critical fill level has reached. Fill Level Control ⹅ Warns in time before your containers spill Empty Level Control ⹅ Warns in time before your containers drai

Open the catalog to page 9
The Solution: SCAT Europe Level Control Systems - 10

Level Control Level Control Disc Sensor Sets 117 988 HPLC-Disposal Safety Funnels Level Control Signalbox T5 - EU, 5x disc sensor fill state, 5x 3 m signal cable, 5x 2 m hook and loop fastener for disc sensor incl. 220/230V EU power supply Signalbox T1 - EU, with disc sensor, alarm at fill state, 3 m signal cable, 2 m hook and loop fastener for disc sensor, 220/230V EU power supply Signalbox T1 - EU, with disc sensor, alarm at empty state, 3 m signal cable, 2 m hook and loop fastener for disc sensor, 220/230V EU power supply Signalbox T1 - USA, with disc sensor, alarm at fill state, 3 m...

Open the catalog to page 10
The Solution: SCAT Europe Level Control Systems - 11

Level Control Level Control Mechanical Reliable protection against spilling during the filling of barrels. SCAT Safety Waste Caps are also available with a mechanical level control. More on this topic from page 75. ARNOLD funnels without ball-valve are suitable for high flow rates or highly viscous liquids. More on this topic from page 110. Adapter with Level Control for Funnel ⹅ R2" BSP/G2" (m) to GL45 (m) Level Indicator for Barrels ⹅ G3/4" (m

Open the catalog to page 11
The Solution: SCAT Europe Level Control Systems - 12

Level Control Level Control Mechanical ߅ Safety Funnels Electrostatic conductive Level indicator, mechanical, for barrels, for containers up to 200 litre, Length of floater = 86 mm, diameter = 18 mm Level indicator, mechanical, for barrels, for containers up to 200 litre, Length of floater = 150 mm, diameter = 18 mm Adapter for funnels with mechanical level control, barell double thread R2" BSP/G2" (m) to GL 45 (m) Adapter for funnels with mechanical level control, barell double thread R2Ԣ BSP/G2” (m) to GL 45 (m) Adapter for funnels with mechanical level control, barrel thread BCS 70x6 (m)...

Open the catalog to page 12

All S.C.A.T. Europe GmbH catalogs and technical brochures