Overview: The document describes a camera adapter designed for integration with galvanometer scan heads, enabling camera-based observation of the working field. This is particularly useful for process monitoring and determining workpiece orientation during laser processing.
Specifications: The camera adapter is compatible with various scan heads from SCANLAB, including hurrySCAN, intelliSCAN, SCANgine, SCANcube, and intellicube. It supports four alternative orientations for the camera objective and is equipped with a dichroic beam splitter to decouple light from the workpiece for camera observation while allowing the laser beam to pass through unattenuated. The adapter supports various wavelengths and allows for the attachment of a camera via a C-mount.
Installation: The adapter is mounted between the scan head's beam entrance and the laser flange. It includes adjustable beam splitter housing for different orientations of the camera and objective unit.
Operation Principle: The adapter uses a beam splitter to direct light from the workpiece to the camera, while the laser beam continues to the scan system. The camera objective, iris diaphragm, and optional color filters are housed within the beam splitter housing. Focus is manually adjustable.
Observation Field and Resolution: The observation field size is influenced by the focal lengths of the scan and camera objectives and the camera chip size. Typical configurations provide a field size of approximately 7.5 mm x 10 mm with a maximum optical resolution of around 10 µm.
Optical Configurations: The document provides typical optical configurations for different laser wavelengths (1064 nm, 532 nm, 355 nm, 266 nm) and corresponding observation wavelengths, scan head apertures, and processing field sizes.
Common Specifications: The adapter supports a maximum entering beam diameter of 30 mm, a C-Mount camera connection, a maximum chip size of 2/3”, and weighs approximately 1.6 kg without the camera. The operating temperature is 25 °C ± 10 °C.
Additional Information: The camera adapter is part of SCANLAB’s camera vision package and is available for further details through SCANLAB America and SCANLAB AG.
See more

Catalog excerpts

Camera Adapter-1

Camera Adapter vision for scan heads The camera adapter enables camera-based observation of a gal- vanometer scan head's working field. Typical applications include process monitoring or determination of a workpiece's orientation during laser processing. The camera adapter ensures easy integration into new as well as existing systems. The adapter's mechanical interfaces enable straight forward mounting between the scan head and laser flange. The system allows 4 alternative orientations of the objective with camera To facilitate monitoring of work surfaces, light arriving from the workpiece is decoupled via the adapter's beam splitter and direc- ted through the camera's objective onto its imaging chip. The laser beam on the other hand passes practically unattenuated through the beam splitter to the scan system. Optical configurations are available for various wavelengths. Customers can freely select a camera suitable for their requirements and attach it via a C-mount. The camera adapter is specifically designed for maximum observa- tion field size and its integrated iris diaphragm can be adjusted for optimal imaging quality. In addition, color or interference filters The camera adapter is also available as a part of SCANLAB's camera vision package.

 Open the catalog to page 1
Camera Adapter-2

Camera Adapter The camera adapter is mounted between the scan head's beam entrance and the laser flange (see drawing). The bore holes at the camera adapter's beam entrance and exit side are compatible with the mounting intellicuöe® scan heads from SCANLAB. The beam splitter housing can be adjusted so that the camera and objective unit are oriented either up, down or sideways (see The camera adapter enables camera-based observation of a scan head's working field. Therefore, a dichroitic beam splitter inside the beam splitter housing decouples light reflected from the illuminated workpiece and...

 Open the catalog to page 2

All SCANLAB GmbH catalogs and technical brochures

  1. excelliSHIFT

    1  Page

  2. dynAXIS 421

    4  Pages

  3. palmSCAN

    2  Pages

  4. laserDESK

    4  Pages

  5. basiCube

    2  Pages

  6. basiCube14

    2  Pages

  7. rtc4

    2  Pages

  8. intelliscanse

    2  Pages

  9. dynaxis

    2  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.