1. Catalogs
  2. Scancon
  3. Type SCA16

Type SCA16

Type SCA16

Type SCA16

Product catalog summary
Mechanical Specifications
The SCA16 encoder features a housing made of aluminum or brass, with an aluminum cap and brass shaft. It weighs approximately 15 grams, with the cable adding 50 grams per meter. The bearing life exceeds 1.9 x 1010 revolutions at rated load, and the shaft speed can reach up to 12,000 rpm. The starting torque is less than 0.005 Nm at 25°C, and the mass moment of inertia is 0.25 gcm². The hollow shaft can handle axial and radial loads of up to 10 N.

Electrical Specifications
The encoder operates on an incremental code with a resolution of up to 5,000 pulses per revolution (ppr). It requires a supply voltage between 4.5 Vdc and 30 Vdc, with a maximum current of 35 mA without load. The output format includes two-channel quadrature with an index and optional complementary outputs. The frequency response is up to 200 kHz, and the encoder is protected against reverse polarity and output short circuits. It complies with EN61000-6-2:2005 and EN61000-6-3:2007 for electromagnetic compatibility.

Environmental Specifications
The operating temperature range is -20°C to +70°C, with a storage temperature range of -20°C to +85°C. The encoder can withstand shocks of 100 G for 11 ms and vibrations from 10-2000 Hz at 10 G. It has an enclosure rating of IP 50, with an option for IP 65.

Connection Options
The encoder can be connected via an 8-lead shielded cable or a 10-lead flat cable with an IDC connector. The standard cable length options are 0.5 m, 1 m, or 2 m.

Ordering Information
The ordering code for the SCA16 encoder includes specifications for pulses per revolution, output type, hollow shaft diameter and length, IP rating, cable length, takeout direction, and connector type. Additional options are available upon request.
See more

Catalog excerpts

Type SCA16-1

Automation / Micro Electrical Specifications Shaft Encoder - Mechanical Specifications Material: Housing: Aluminum / Brass Cap: Aluminum Shaft: Brass Encoder: ~ 15 gr (0,53 oz) Cable: 50 gr / meter (1,76 oz / meter) Bearing Life: > 1,9 x 1010 revolutions at rated load Bearing Pre-Load: Shaft Speed: Starting Torque: Mass Moment of Inertia: Hollow Shaft Loads: Supply Voltage: Output Voltage: Low: 500 mV max. at 10 mA High: (Vin – 0,6) at -10 mA (Vin – 1,3) at -25 mA 20 mA max. load per output channel Output Current: Frequency Response: Output Format: Two channel (A, B) quadrature with Index (Z) and optional complementary (A-, B-, Z-) outputs Phase Sense: A leads B clockwise (CW) from the mounting end of the encoder Environmental Specifications Operating Temp.: Gated with Channels A and B high Storage Temp.: Electrical Protection: Reverse polarity and output short circuit protected Enclosure Rating: IP 50 / Nema 5 (approx.) IP 65 /Nema 4 (approx) Noise Immunity: Tested to EN61000-6-2 : 2005 (industrial environments) Electromagnetic compatibility (EMC) and EN 61000-6-3 : 2007 (residential, commercial, and lightindustrial environments) for Electromagnetic compatibility (EMC) Connection Options Cable: 8 leads (0,05 mm2, 30 AWG) twisted pairs; shielded Flat Cable: 10 lead flat cable with IDC connector **= It is recommended user not to combine max. value for all 3 parameters

 Open the catalog to page 1
Type SCA16-2

Type SCA16 Output waveform Disk Resolutions (pluses per revolution) Other options on request Pulses per revolution, min. 1 – max. 5.000 Channel tolerance Phase difference tolerance Z channel tolerance Mechanical Dimensions Tolerances according to ISO 2768 f

 Open the catalog to page 2
Type SCA16-3

Standard Cable Gland Flat Ribbon Cable with IDC connector

 Open the catalog to page 3
Type SCA16-4

Type SCA16 Output Terminations Standard Cable Flat Cable w/ IDC Connector Differential Output* Differential Output Inverted Output** Wire Color Pink Gray Green Yellow White Brown Red Blue * Hewlett Packard (HP) compatible ** ID # required for ordering IP 50 rating CE mark not available 0,5 m, 1 m, or 2 m cable length only

 Open the catalog to page 4
Type SCA16-5

Type SCA16 Ordering Code Pulses per Output Revolution Hollow Shaft Length Cable Takeout Length Standard Cable Standard is 1 meter Specify length Flat Cable w/ IDC* 0,5 meter 1,0 meter Differential Inverted (Flat cable option only) Back (axial) Flat cable w/ IDC connector* IDC on flat cable No connector Other options on request: Please contact Scancon A/S See Accessories for drawings

 Open the catalog to page 5
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.