SCA-BM - 1

Automation / Mini Type SCA-BM Supply Voltage: Output Voltage: Output Current: Frequency Response: Output Format: Phase Sense: Electrical Specifications Mechanical Specifications Incremental 1 to 7500 ppr (pulses per revolution) 4,5 Vdc min. to 30 Vdc max. (35 mA max. - no load) Low: 500 mV max. at 10 mA High: (Vin – 0,6) at -10 mA (Vin – 1,3) at -25 mA 25 mA max. load per output channel 200 kHz max. Housing: Brass Cap: Electroplated Steel Aluminum (flat cable option) Shaft: Stainless Steel Encoder: ~ 40 gr (1,41 oz) Cable: 50 gr / meter (1,76 oz / meter) Bearing Life: > 1,9 x 1010 revolutions at rated load Shaft Speed: Starting Torque: Mass Moment of Inertia: Shaft Loads: Two channel (A, B) quadrature with Index (Z) and optional complementary (A-, B-, Z-) outputs A leads B clockwise (CW) from the mounting end of the encoder Environmental Specifications Operating Temp.: Gated with Channels A and B high Storage Temp.: ASIC Push pull and Differential OL7272 Push-pull and Differential Line Driver 26C31 Differential Line Driver 5V output (with 5V input) Reverse polarity and output short circuit protected Enclosure Rating: IP 50 / Nema 5 (approx.) IP 64 / Nema 4 (approx.) – flat cable Electrical Protection: Noise Immunity: Tested to EN61000-6-2 : 2005 (industrial environments) Electromagnetic compatibility (EMC) and EN 61000-6-3 : 2007 (residential, commercial, and lightindustrial environments) for Electromagnetic compatibility (EMC) Connection Options Cable: 8 leads (0,05 mm2, 30 AWG) - Differential 5 leads (0,14 mm2, 26 AWG) - Standard twisted pairs; shielded Flat Cable: 10 lead flat cable with IDC connector **= It is recommended, not to combine max. Value for all 3 parameters

Open the catalog to page 1
SCA-BM - 2

Type SCA-BM Output waveform Disk Resolutions (pulses per revolution) Other options on request Pulses per revolution, min. 1 – max. 7.500 Channel tolerance Phase difference tolerance Z channel tolerance Mechanical Dimensions

Open the catalog to page 2
SCA-BM - 3

Type SCA-BM Output Terminations Standard Cable Standard Output Channel A AB BZ ZVsup GND Flat Cable w/ IDC Connector Differential Output Wire Color Green NC Yellow NC Gray NC Brown White GND = Circuit Ground Differential Output * Position Pink Gray Green Yellow White Brown Red Blue * Hewlett Packard (HP) compatible mm (inches) mm (inches) mm (inches) IP 50 rating CE mark not available 0,5 m, 1 m, or 2 m cable length only

Open the catalog to page 3
SCA-BM - 4

Type SCA-BM Ordering Code Type SCA-BM Shaft Length Cable Length Cable Takeout Standard Standard – Open Collector NPN Standard – Open Collector PNP Differential 26C31 Line Driver OL 7272 Line Driver Standard - with built-in TSM ** Standard Cable Standard is 1 meter Specify length Flat Cable w/ IDC 0,5 meter Side (radial) Back (axial) Flat cable w/ IDC connector ** Designed specifically for Wind Power applications. Other options on request: Please contact Scancon A/S See SCA24 COC under Industries – Wind Power – SCA24 for additional conformity standards testing. TSM = Transient Suppression...

Open the catalog to page 4

All Scancon catalogs and technical brochures

  1. 2R58

    5 Pages

  2. SCH94FO

    5 Pages

  3. SCH32F

    5 Pages

  4. SCH32B

    5 Pages

  5. SCH24

    5 Pages

  6. 2RMHF

    5 Pages

  7. 2SUN

    3 Pages

  8. SCA41

    5 Pages

  9. SCA40

    5 Pages

  10. SCA38

    5 Pages

  11. SCA36,5

    5 Pages

  12. SCA34

    5 Pages

  13. SCA30

    5 Pages

  14. SCA28

    5 Pages

  15. SCA24-IP65

    4 Pages

  16. SCA24

    5 Pages

  17. SCH16F

    5 Pages

  18. Type SCH16G

    4 Pages

  19. Type SCA787

    4 Pages

  20. Type SCA18

    4 Pages

  21. Type SCA16

    5 Pages

  22. Type SCH68B

    5 Pages

  23. Type SCA50

    5 Pages

  24. Type 2RMHD

    4 Pages