1. Catalogs
  2. Scancon
  3. Explosion Proof-Absolute Flange Size:Ø78 mm or 161x100x100 mm Shaft and Hollow Shaft

Explosion Proof-Absolute Flange Size:Ø78 mm or 161x100x100 mm Shaft and Hollow Shaft

Explosion Proof-Absolute Flange Size:Ø78 mm or 161x100x100 mm Shaft and Hollow Shaft

Explosion Proof-Absolute Flange Size:Ø78 mm or 161x100x100 mm Shaft and Hollow Shaft

Product catalog summary
Main Features
The Absolute Rotary Encoder EXAG is an explosion-proof device approved under II 2 G/D EEx d II C T6. It is a heavy-duty industrial model with a synchronous-serial interface (RS 422). It supports up to 65536 steps per revolution (16 Bit) and 16384 revolutions (14 Bit) with Gray or Binary code options.

Mechanical Structure
The encoder features a flameproof enclosure with an aluminum flange and housing, a stainless steel shaft, and precision ball bearings. The code disc is made of durable plastic.

Applications
It is suitable for sensing angles, distances, tracks, inclinations, and differences between axes.

Electrical Features
The encoder includes a temperature-insensitive IR-opto-receiver-ASIC, polarity inversion protection, and over-voltage-peak protection. It uses SMD technology for a highly integrated circuit.

Technical Data
  • Clock input via opto-coupler and data output line-driver according to RS 422.
  • Clock frequency ranges from 100 kHz to 2 MHz.
  • Supply voltage is 10-30 V DC with a power consumption of max. 1 W.
  • Electrical lifetime exceeds 105 hours.
  • EMC compliance with EN 61000-6-4 and EN 61000-6-2.

Mechanical Data
  • Housing made of aluminum with a max shaft loading of 50 N both axially and radially.
  • RPM varies with protection class: IP65 (3000 RPM), IP54 (6000 RPM), IP67 (1200 RPM).
  • Shock resistance up to 100 g and vibration resistance up to 10 g.

Environmental Conditions
Operating temperature ranges from -40 to +70°C, with storage temperatures up to +85°C. The device has a protection class of IP65.

Ex-Protection
The encoder is classified under II 2 G/D EEx d II C T6, suitable for gas and dust environments, excluding mining. It features a flameproof enclosure and complies with EN50014 and EN50018.

Interface
The encoder uses a Synchronous Serial Interface (SSI) with transmission rates up to 10 MBit/s and a transfer distance of up to 1200 m. It supports up to 32 encoders on the same data line.

Installation
Signal lines and power supply are connected via screw terminals. The connection cap accommodates cable diameters from 6.5 to 8 mm. Proper installation is crucial to maintain ATEX certification.

Models/Ordering Description
The encoder is available in various configurations, including different codes (Gray or Binary), revolutions, steps per revolution, shaft types, materials, and protection ratings. Accessories like shaft coupling are available.

Note
Specifications are subject to change without notice, and the manufacturer does not assume responsibility for technical inaccuracies or omissions.
See more

Catalog excerpts

Explosion Proof-Absolute Flange Size:Ø78 mm or 161x100x100 mm Shaft and Hollow Shaft-1

- Approval: Main Features Applications - Sensing of - Angles II 2 G/D EEx d II C T6 - Distances > - Heavy-duty industrial model - Tracks > - Interface: Synchronous-serial (RS 422) - Inclinations - > - Ex-proof, flameproof enclosure Max. 65536 steps per revolution (16 Bit) Mechanical Structure - > - Flange and housing of Aluminum Max. 16384 revolutions (14 Bit) Electrical Features - > - Shaft of stainless steel Code: Gray or Binary - > - Temperature insensitive IR-opto-receiver-ASIC with integrated signal conditioning Differences between two or more axes - Precision ball bearings with sealing or cover rings - Only one IR-transmitter-diode per opto-ASIC - Highly integrated circuit in SMD -technology - Polarity inversion protection - Over-voltage-peak protection > - Code disc made of unbreakable and durable plastic > Tranevang 1, 3450 Allerָd, Denmark Tel: +45 48172702 Fax: +45 48172284 e-mail: [email protected] www.scancon.dk or www.scancon.cn Page 20 >

 Open the catalog to page 1
Explosion Proof-Absolute Flange Size:Ø78 mm or 161x100x100 mm Shaft and Hollow Shaft-2

Electrical data Clock input via opto-coupler Data output Line-driver according to RS 422 Clock frequency 100 kHz - 2 MHz Step frequency LSB max. 800 kHz (valid code) Accuracy of division ֽ LSB (12 bit), 2 LSB (16 bit) Supply voltage 10-30 V DC (absolute limits) * Turn on time < 1 s Power consumption max. 1 W Electrical lifetime > 10 > 5 h EMC emitted interference: EN 61000-6-4 noise immunity: EN 61000-6-2 Connection connection cap і screw terminals > * Supply voltage according to EN 50 178 (safety extra-low voltage) Mechanical Data Housing Aluminum Max. shaft loading Axial 50 N, radial 50 N Inertia...

 Open the catalog to page 2
Explosion Proof-Absolute Flange Size:Ø78 mm or 161x100x100 mm Shaft and Hollow Shaft-3

SCANCON encoders type series EXAG are classified according to Ex-Protection > Note: For ambient temperatures below ֖10C and above +60аC use field wiring suitable for both minimum and maximum ambient temperature. II 2 G/D EEx d II C T6: II 2 G/D EEx d II C T6 Temperature Class T6: Maximum surface temperature: + 85C Explosion Sub-Group C: Hydrogen (H > 2 ) , Acetylene (C > 2 H > 2 ), carbon disulfide (CS > 2 ) Explosion Group: for all areas except for mining Method of protection: flameproof enclosure Device in compliance with EN50014 and EN50018 Application Area: permitted for gas und dust Equipment-Category...

 Open the catalog to page 3
Explosion Proof-Absolute Flange Size:Ø78 mm or 161x100x100 mm Shaft and Hollow Shaft-4

Synchronous Serial Interface (SSI) Driver Driver meets EIA standard RS 422; transmission rates up to 10 MBit/s Transfer Transfer distance up to 1,200 m Transmission Balanced transmission provides high noise immunity Pair lines Shielded and twisted pair lines are essential to attain extremely high noise immunity Interface For a detailed description of the synchronous-serial interface (SSI) refer to introduction section. Optional Built-in RS 422 interface for bus mode (strobe-function). Up to 32 encoders (AWC) can Single Shift be used on the same data line ! > Taktsequenz 1 2 3 4 5 6 n n+1Clock...

 Open the catalog to page 4
Explosion Proof-Absolute Flange Size:Ø78 mm or 161x100x100 mm Shaft and Hollow Shaft-5

Follow the instructions in the installation ma- nual carefully, otherwise the ATEX-certification will repealed! > Signal lines and power supply are connected via screw terminals in the connection cap. The connection cap can be opened for installation by removing the six cap screws. The cable gland is suitable for cable diameters from 6.5 up to 8 mm. Installation Terminal Description 1 (left) 0 V 2 10 ֖ 30 V 3 Complement 4 N.C. 5 Clock + 6 Clock - 7 Data - 8 (right) Data + > -+ CD- T+T- D+ Assignment of the 8pin screw terminal: Page 24 >

 Open the catalog to page 5
Explosion Proof-Absolute Flange Size:Ø78 mm or 161x100x100 mm Shaft and Hollow Shaft-7

Descri p tion T yp e ke y Ex-Proof Optocode EXAG- _ _ _ _ _ - _ _ _ _ - _ - _ _ - _ _ - _ _ - _ _ - _ - _ _ Interface SSI SL Version 00 Code Gray G Binary B Revolutions (Bits) Singleturn 00 Multiturn (4096 revolutions) 12 Multiturn (16384 revolutions) 14 Steps per Revolution 4096 12 ( Bits ) 8192 13 Shaft or Solid Shaft A Hollow Shaft Hollow Shaft H Material Aluminum AL Stainless Steel VA Shaft diameter 10 mm 10 Shaft length 20 mm 20 Hollow shaft diameter 14 mm 14 Deep 35 mm 35 P Rating IP65 (further on request) 65 Flange Clamping Flange C Connection Connection Cap Field Bus ֖ radial cable outlets...

 Open the catalog to page 7
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.