1. Catalogs
  2. Scancon
  3. DIN Rail Junction Box

DIN Rail Junction Box

DIN Rail Junction Box

DIN Rail Junction Box

Product catalog summary
Electrical Specifications
The junction box operates with a supply voltage range of 4.75V to 30V. Typical current consumption varies with supply voltage: 250 mA at 5V, 110 mA at 15V, and 70 mA at 30V, excluding the encoder. It supports differential encoder inputs with a maximum frequency of 100 kHz and input voltage equal to the supply voltage.

Common Specifications with Receiver
The update rate is 1.04 million updates per second, with a transmission delay of ≤ 3 µsec. An additional 1 µsec is added per 200 meters of fiber optic cable. The standard ST optical fiber connectors have an insertion loss of ≤ 0.7 dB, with 0.4 dB recommended. The recommended optical fiber is 62.5/125 µm, multimode, with an optical wavelength of 850 nm. Transmission distance can reach up to 2,000 meters.

Mechanical Specifications
The box is made of UL94-V0 self-extinguishing ABS with stainless steel front and cover plates. It weighs approximately 150 grams and measures 101 x 119 x 22.5 mm. It is designed for DIN rail mounting according to EN-50022 for 35mm rails.

Environmental Specifications
The operating temperature range is -20° to +70° C, and the storage temperature range is -40° to +85° C. It can withstand 98% relative humidity without condensation, 100 G shock for 11 ms, and vibration of 10 G from 10-2000 Hz. The enclosure rating is IP 40, and it complies with EMC standards EN 61000-6-2:2005 and EN 61000-6-3:2007.

Features
The junction box transmitter supports fiber optic transmission up to 2,000 meters without signal degradation from electrical disturbances. It offers high encoder frequency, low transmission delay, and added safety with two redundant fibers. It is compatible with all Scancon fiber optic receivers for incremental encoders and supports DIN rail mounting.

Mechanical Dimensions and Indicators
The front panel includes indicators for channels A, B, and Z from the encoder, as well as a power indicator.

Terminal Connections
The terminal connections include inputs for shield, ground, and positive supply for both transmitter and encoder, as well as channels A, B, and Z with their inverted inputs.

Ordering Code
The connection ordering code for the junction box transmitter is DINJB-TX-INC.
See more

Catalog excerpts

DIN Rail Junction Box-1

DIN Rail Junction Box Junction Box Transmitter for Incremental Encoders Compatible with all Scancon Fiber Optic Receivers for Incremental Encoders Mechanical Specifications Supply Voltage Current Consumption (typical) 250 mA @ Vsup = 5V (excl. encoder) 110 mA @ Vsup = 15V (excl. encoder) 70 mA @ Vsup = 30V (excl. encoder) Encoder Inputs Differential inputs Vhigh 2/3 Vsup Vlow 1/3 Vsup Maximum input voltage equal to Supply voltage Encoder Frequency Encoder Supply Voltage Identical to Transmitter Supply voltage Common Specifications with Receiver Optical Fiber Connectors Added Safety by use of two Redundant Fibers Transmission Delay High Encoder Frequency and Low Transmission Delay Update Rate No Degradation of Encoder Signal from Electrical Disturbances Electrical Specifications Fiber Optic Transmission up to 2000 meters 1.04 million updates / second ~ 0.96 µsec. / update 3 µsec. Approx. 1 µsec. must be added per 200 meters of fiber optic cable Standard ST Insertion loss 0.7 dB ( 0.4 dB recommended ) Recommended Optical Fiber Optical Wavelength Transmission Distance 1,000 meters 2,000 meters (option) Box: UL94-V0 self extinguishing ABS Color: Anthracite Front and cover plates: Stainless steel Approx. 150 gr. (5.3 oz) including terminal block connector DIN Rail Mounting in accordance with EN-50022 for 35mm. rails Environmental Specifications Operating Temperature Storage Temperature Enclosure Rating EN 61000-6-2 : 2005 (industrial environments) EN 61000-6-3 : 2007 (residential, commercial, and light-industrial environments)

 Open the catalog to page 1
DIN Rail Junction Box-2

Junction Box Transmitter Incremental Encoders Mechanical Dimensions Front Panel Indicators Channel A from encoder On = high Channel B from encoder On = high Channel Z from encoder On = high Power indicator On = Power On

 Open the catalog to page 2
DIN Rail Junction Box-3

Industrial Encoders Incremental Encoders Scancon Tranevang 1 3450 Allerod Denmark P- 3

 Open the catalog to page 3
DIN Rail Junction Box-4

Junction Box Transmitter Incremental Encoders Ordering Code Connection DINJB –TX – INC

 Open the catalog to page 4