Overview: The PM130 PLUS is a versatile, high-performance three-phase AC power meter suitable for various users, including electrical panel builders and substation operators. It features a compact design, a bright LED display, and multiple communication ports for both local and remote readings.
Models: The series comprises three models: PM130P (basic), PM130E (with energy measurements and data logging), and PM130EH (with harmonic analysis capabilities).
Key Features:
  • Multifunctional power meter with true RMS measurements, demand meter, and frequency capabilities.
  • Billing/TOU energy meter with Class 0.5S accuracy, time-of-use registers, and programmable tariff schedules.
  • Harmonic analyzer for voltage and current THD, TDD, and K-Factor up to the 40th harmonic.
  • Real-time waveform capture and programmable logical controller with relay output control.
  • Event and data recording with non-volatile memory and programmable data logs.
  • Various I/O options including digital inputs, relay outputs, and analog outputs.
  • Standard and optional communication ports supporting multiple protocols, including Modbus and DNP3.
Technical Specifications:
  • Environmental conditions: Operating temperature from -30°C to 60°C, storage temperature from -40°C to 85°C, and humidity up to 95% RH non-condensing.
  • Construction: Weighs 0.70kg with dimensions of 114×114×109mm.
  • Power supply options include 120/230V AC-DC, 12 VDC, and 24/48 VDC.
  • Voltage and current input ratings with high isolation and overload withstand capabilities.
  • Sampling rate of 128 samples per cycle for accurate measurements.
Standards Compliance: The PM130 PLUS adheres to various international standards for accuracy, electromagnetic immunity, and safety, including IEC and ANSI standards.
Ordering Information: Detailed order strings are provided for different models, options for current inputs, calibration frequencies, power supply, communication protocols, mounting options, and expansion modules.
Specifications:
  • ACS 26x23.8mm hole CS2S: Designed for 200A applications with a 26x23.8mm hole.
  • 200A Split Core HACS 23×33mm hole CS2SL: Suitable for 200A applications with a 23x33mm hole.
  • 400A Solid Core HACS Φ26mm hole CS4: Designed for 400A applications with a 26mm diameter hole.
  • 400A Split Core HACS 23×33mm hole CS4S: Features a 23x33mm hole for 400A applications.
  • 800A Solid Core HACS 100×32mm / Φ62mm hole CS8: Designed for 800A applications with a 100x32mm or 62mm diameter hole.
  • 800A Split Core HACS 80×50mm hole CS8S: Features an 80x50mm hole for 800A applications.
  • 1200A Split Core HACS 80×121mm hole CS12S: Designed for 1200A applications with an 80x121mm hole.
See more

Catalog excerpts

PM130 PLUS Datasheet-1

rful Solutions HIGH PERFORMANCE The PM130 PLUS is a compact, multi-function, three-phase AC powermeter specially designed to meet the requirements of users ranging from electrical panel builders to substation operators. The PM130 PLUS measurement inputs and power supply comply with Measuring Category II. The PM130 PLUS series includes: ■» A bright 3-row LED display enabling easy reading of local meters ■» A standard RS-485 communication port and an additional plug-in RS-232/RS-422/RS-485, Ethernet, Profibus, GPRS and RF port module (RF is available in certain regions only), enabling local and remote automatic meter readings and setup ■> Selection of I/O plug-in modules ranging from 4DI/2DO, 4AO and up to 12DI/4RO with All models are suitable for mounting on both 4-inch round and 92x92mm square cutouts The PM130 PLUS series offers 3 types of models: PM130P The basic model, providing standard voltage, current, power & frequency PM130E Offers all the features of the basic model plus energy measurements and data logging. This version is available in certain regions only. plus harmonic analysis capabilities. Power Meter ■» 3 voltage inputs and 3 current transformer-isolated AC inputs for direct connection to power line or via potential ■» True RMS, volts, amps, power, power factor, neutral current, voltage and current unbalance, frequency ■» Ampere/Volt demand meter to change without notice. Copyright i

 Open the catalog to page 1
PM130 PLUS Datasheet-2

rful Solutions Billing/TOU Energy Meter (PM130E active and reactive energy polyphase static ■» Three-phase total and per phase energy measurements; active, reactive and apparent energy counters ■» Time-of-Use, 4 totalization and tariff energy/demand registers x 8 tariffs, 4 seasons x 4 types of days, 8 tariff changes ■» One-time easy programmable tariff calendar schedule ■» Automatic daily energy and maximum demand profile log for total and tariff ■» Voltage and current THD, current TDD and K-Factor, up to 40th order harmonic ■» Voltage and current harmonic spectrum Real-time Waveform Capture...

 Open the catalog to page 2
PM130 PLUS Datasheet-3

rful Solutions ■> Protocols: Modbus RTU, ASCII, DNP3.0, Optional IEC 60870-5-101; With Ethernet 60870-5-104 and with GPRS module: ■» ExpertPower™ client for communicating with SATEC ExpertPower™ Internet services (with Ethernet or GPRS modules) ■» TCP notification client for communicating with a remote Modbus/TCP server on events or periodically on a time basis (with the Ethernet or GPRS module) ■» Direct voltage measurement of up to 690v ■» Selection of current input connection: RS5 - allowing connection remotely of 5A conventional CTs with split core remote ■» HACS - selection of remote sensors...

 Open the catalog to page 3
PM130 PLUS Datasheet-4

Technical Specifications ENVIRONMENTAL CONDITIONS Case enclosure plastic PC/ABS blend Front panel Packaging case (Polyethylene Foam) brackets POWER SUPPLY Input Ratings VOLTAGE INPUTS Operating range Wire size 5A SECONDARY or 5A REMOTE SENSOR (RS5) Operating range Continuous 10A RMS section wire) Operating range Continuous 2A RMS section wire) HACS REMOTE SENSORS Depends on sensor rating. See HACS datasheet SAMPLING RATE MEASUREMENT Sampling rate 128 samples/cycle OPTIONAL RELAY OUTPUTS ELECTROMECHANICAL RELAY Dry Contact, Option (4DI/DO or 12DI/DO Optional module) contact (SPST Form A) Galvanic...

 Open the catalog to page 4
PM130 PLUS Datasheet-5

Operate time Release time Update time Wire size SOLID STATE RELAY OPTION 2 relays rated at 0.15A/250 V AC/DC, 1 contact Operate time Release time Update time Connector type Removable, 4 pins Wire size OPTIONAL DIGITAL INPUTS Optional module) Dry Contacts, internally wetted @ Open @ input resistance Internal power External power Scan time Connector type Removable, 5 pins Wire size OPTIONAL ANALOG OUTPUTS 4 Analog Outputs optically isolated Ranges ■> +1 mA, maximum load 5 kQ (upon order) (100% overload) Power supply Update time Connector type Removable, 5 pins Wire size Communication Ports RS-485...

 Open the catalog to page 5
PM130 PLUS Datasheet-6

rful Solutions RS-232 or RS-422/485 optically isolated port Baud rate Supported Modbus RTU, DNP3, and SATEC protocols ASCII Connector type Wire size REAL-TIME CLOCK Standard Meter ■> Accuracy: typical error 1 ■> Typical clock retention time: TOU Module Battery-backed clock Meter Clock "* Accuracy: typical error 7 ■> Typical clock retention time: DISPLAY MODULE High-brightness seven-segment digital LEDs, two 4- digit + one 5 digit windows 3 color led load bar graph (40-110%) Standards Compliance Electromagnetic Immunity ■> IEC 61000-4-4 level 3: Electric Fast ■> IEC 61000-4-6 level 3: Conducted...

 Open the catalog to page 6
PM130 PLUS Datasheet-7

PM130 PLUS Order String Power Version Energy and Harmonic Version Energy Only Current Inputs 5A split core remote high accuracy current sensor (HACS) High Accuracy Current Sensors (HACS). Requires ordering of 3 HACS (see HACS Order String on next page) Power Supply Communication Protocol Panel Mount (standard) Expansion Module (Max. 1 module per instrument, can be ordered separately) 4 Analog Outputs: +lmA Ethernet (TCP/IP) 4 Digital Inputs (Dry Contact) / 2 Relay Outputs 250V/5A AC 4 Digital Inputs (Dry Contact) / 2 SSR Outputs 250V / 0.1A AC 12 Digital Inputs (Dry Contact)/4 Relay Outputs 250V/5A...

 Open the catalog to page 7
PM130 PLUS Datasheet-8

rful Solutions HACS (High Accuracy Current Sensors) Order String High Accuracy Current Sensors SATEC Proprietary High Accuracy Current Sensors (HACS) designed to be used with our HACS-ready meters and analyzers. SATEC current sensors have several benefits over CTs: 2. Wide bandwidth (for harmonics measurement) 3. Safe to use - no need for shorting bars 4. Longer cable - up to 200m without performance reduction 100A Solid Core HACS 012mm hole CS1 100A Solid Core HACS 023mm hole CS1L 100A Split Core HACS 016mm hole CS1S 200A Split Core HACS 26x23.8mm hole CS2S 200A Split Core HACS 23x33mm hole...

 Open the catalog to page 8

Archived catalogs

  1. PM175 Specs

    4  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.