EM920 eXpertmeter - Socket Meter - Brochure - 1

Powerful Solutions HIGH PERFORMANCE REVENUE SOCKET METER CUTTING EDGE POWER QUALITY ANALYZER FAST TRANSIENT & FAULT RECORDER

Open the catalog to page 1
EM920 eXpertmeter - Socket Meter - Brochure - 2

Advanced Metering Infrastructure (AMI) has reached new heights with SATEC's latest introduction in energy and power quality measurements for smart grid deployments. The SATEC Model EM920 eXpertmeter™ is an advanced energy analyzer in a socket meter with precise measurement and expansion capabilities. The EM920's unique "Add-On" modularity is the key to its remarkable versatility and unprecedented effort to add intelligence, control and communications to electrical metering. SATEC's "Add-On" module concept allows you to configure the meter to your changing needs, thus saving valuable time in...

Open the catalog to page 2
EM920 eXpertmeter - Socket Meter - Brochure - 3

□ Modularity: Add-On module support to configure and change with your growing needs, instead of requiring complete assemblies that can only be changed at the factory □ Add on I/O slots. Add inputs to count other pulses or add outputs to generate energy pulse □ Real Time Oscillography. View quality of power (waveform) in real time □ Internal memory for long term data storage—16 MB □ Optional Remote Display Module (RDM) LED front panel display □ True Power Quality EN 50160 Standard □ Precise measurement 0.05% revenue grade accuracy □ Advanced Power Quality waveform recording (4...

Open the catalog to page 3
EM920 eXpertmeter - Socket Meter - Brochure - 4

The EM920 is a high precision, multi-purpose 4 quadrant meter used for active, reactive, and apparent energy / demand measurement and recording. The meter is ideal for grid applications in generation, transmission and distribution utilities. Designed for major industrial and commercial consumers as well. Accuracy class 0.2S approved according to ANSI C12.20 class 10/20 and to IEC 62053-22 class 0.2S, and designed according to even more rigorous SATEC standards. The meter delivers precision, reliability and long-term stability. An all in one meter, the EM920 is the answer to Precise metering...

Open the catalog to page 4
EM920 eXpertmeter - Socket Meter - Brochure - 5

High Performance Revenue Meter

Open the catalog to page 5
EM920 eXpertmeter - Socket Meter - Brochure - 6

The EM920 is among the most advanced power quality analyzer and recorder on the market. The instrument is a product of SATEC's 20 years of experience in the creation of power quality instruments. The EM920 is designed to fully comply with the most demanding industry standard, IEC 61000-4-30 Class A. It provides power quality reports and statistics according to EN 50160, complimented by comprehensive power quality event/ data log with waveforms (3 voltage and 4 current inputs for waveform recording) available for detailed Power Quality event analysis. The individual harmonics and...

Open the catalog to page 6
EM920 eXpertmeter - Socket Meter - Brochure - 7

Power Quality Events Via PAS Software DIREC TIO VOLTAGE TION INTERRUP

Open the catalog to page 7
EM920 eXpertmeter - Socket Meter - Brochure - 8

The EM920 provides state-of-the-art fast transient recording capability. Transient pulses as short as 17 microseconds can be reliably recorded and analyzed. The EM920 can record such short pulses by a separate electronic channel with a sampling rate of 1024 samples/cycle. The transient amplitude is recorded relative to the ground in accordance with the strict definitions of power quality standards (EN 50160). The instrument can measure transient pulses with an amplitude of up to 2 kV (withstands up to 6 kV). Four voltage waveforms (3 phases and neutral relative to the ground) are recorded...

Open the catalog to page 8
EM920 eXpertmeter - Socket Meter - Brochure - 9

COMMUNICATION □ Reads 5 simultaneous independent communication ports (3 standard): □ Infrared port (Modbus RTU/ASCII and DNP3.0 protocols). Supports IEC 62056-21/61 standard—hardware and protocol specifications for local meter data exchange □ USB 2.0 full speed device port (Modbus RTU protocol, 12 Mbps) for fast local communications and data retrieval □ RS485 universal serial communications port (up to 115,200 bps, Modbus RTU/ASCII and DNP3.0 protocols) OPTIONAL ADD-ON I/O & COMMUNICATION MODULES State-of-the-art communication abilities enabled by the EM920 concept: □ Ethernet 10/100 Base-T...

Open the catalog to page 9
EM920 eXpertmeter - Socket Meter - Brochure - 10

ACCURACY □ ANSI C12.20: Class 10/20: 0.2S □ IEC 62053-22: Class 0.2S POWER QUALITY □ Harmonics and interharmonics measurement: IEC 61000-4-7 class I □ Flicker measurement: IEC 61000-4-15 □ Power quality measurement methods: IEC 61000-4-30 class A/ EN 50160 □ Real-time clock backup and accuracy: IEC 61038 POWER CONSUMPTION □ 5W or 20VA on each voltage input: ANSI C12.1-2008 EMC IMMUNITY □ AC Line Surge: IEEE/ANSI C62.41-2002 □ 100kHz ring wave @ 6kV/0.5kA □ 1.2/50 ps - 8/20 ps Impulse @ 6kV / 3kA □ Magnetic Field: ANSI C12.1 □ EFT/B: IEC 61000-4-4: level 4—4kV AC lines and 2kV I/O and COM...

Open the catalog to page 10
EM920 eXpertmeter - Socket Meter - Brochure - 11

* @80% to 120% of voltage FS, 2% to 200% of current FS and frequency 50/60 Hz.

Open the catalog to page 11
EM920 eXpertmeter - Socket Meter - Brochure - 12

Reference voltage Un 57.73V up Voltage rating: to 120V L-N (standard) 57.73 up to 120 Volts (L-N), 100 to 207 Volts (L-L) Crest factor >2 [VL_N x 1.2 x 2] peak up 288V (for PQ) Maximum Line to Line voltage 500 V r.m.s Temporary over voltage between live conductors and earth 240 V r.m.s Transient over voltage between live conductors and earth 1.5 kV peak (optional, from 15 ps up to ms) Starting voltage1 0.1%Un Burden per phase < 0.2VA Overload withstand for 1 minute phase-to-ground (ANSI C12.1 4000V AC & IEC 62053-22, protective class II) Rated impulse...

Open the catalog to page 12
EM920 eXpertmeter - Socket Meter - Brochure - 13

Technical Specifications Fast Status Input Digital Input optically isolated 2DI (standard) 8DI Optional module Dry contacts, internally wetted Resistance of open contact sensing Resistance of closed contact sensing Sampling rate Insulation Dielectric withstand Terminals for wires size Digital output – SSR optically isolated Operation time Release time Insulation Dielectric withstand Terminals for wires size Blades (Socket meter standard—C12.10) Relay Output Operation time Release time Insulation Dielectric withstand Operation time Release time Insulation resistance of open contacts...

Open the catalog to page 13
EM920 eXpertmeter - Socket Meter - Brochure - 16

MODEL EM920—Form 9S (includes 2DI, 1KYZ relay, USB, RS485 port) OPTIONS VOLTAGE INPUTS Standard - 120 up to 277 Volts AC (L-N) ± 20% (208 to 480 volts L-L) (cannot be combined with auxiliary power supply) Low Voltage 57.73 up to 120 Volts (L-N), 100 to 208 Volts (L-L) via PT CURRENT INPUTS 5 Ampere TRANSIENT CAPTURE Standard (256 samples per cycle) Transient module (transient over-voltages as short as 17 µs are detectable, up to 2 kV amplitude is measurable) COMMUNICATION (MAX. 1 PER DEVICE) Standard (USB, RS-485, IR) Ethernet TX, IRIG-B and additional RS-232/485 Ethernet TX, IRIG-B,...

Open the catalog to page 16

All SATEC catalogs and technical brochures

  1. PM180 Brochure

    16 Pages

  2. ezPAC Brochure

    12 Pages

  3. PM175 Flyer

    1 Pages

  4. PM172E Specs

    3 Pages

Archived catalogs

  1. PM175 Specs