Vivaflow®

Vivaflow®
1 / 12 PagesView full catalog

Vivaflow®

Product catalog summary
Benefits
  • Rapid sample processing with ready-to-use cassettes operated by a standard peristaltic pump.
  • Plug and play simplicity due to unique flip-flow channels ensuring optimal flux.
  • Flexible and modular scalability with various membrane, MWCO, and usage options for samples up to 5 L.
Product Overview

Vivaflow® cassettes bring tangential flow filtration benefits to research and development labs, eliminating the cost and complexity of process-scale systems. They are ideal for ultrafiltration and diafiltration of 0.1 to 5 L samples, offering plug and play convenience with optimal crossflow velocities.

Product Information

The Vivaflow® range offers crossflow devices for concentrating or re-buffering aqueous samples up to 5 L. Operated with a standard peristaltic pump, they provide optimal results without requiring additional equipment or significant process optimization.

  • Vivaflow® 50: Modular, single-use cassette with interlocking design, suitable for 0.1 to 3 L samples.
  • Vivaflow® 50R: Compact cassette with Hydrosart® membrane, ideal for high-value samples like viruses and antibodies, suitable for up to 1 L samples.
  • Vivaflow® 200: Multi-use cassette with PES or Hydrosart® membranes, suitable for up to 5 L samples.
Applications
  • Concentration or diafiltration of recombinant proteins in biopharmaceutical research.
  • Clarification, concentration, or diafiltration of viruses and VLPs from cell culture and environmental samples.
  • Isolation and concentration of viruses and viral nucleic acids from wastewater.
  • Concentration, diafiltration, or free drug removal in nanoparticle research.
  • Concentration of environmental samples prior to trace metals analysis.
Technical Data

Details on materials of construction, dimensions, and operating conditions for Vivaflow® 50, 50R, and 200 cassettes are provided, including pressure and temperature limits.

Working Principle

Vivaflow® cassettes use an ultrafiltration membrane with a peristaltic pump to recirculate samples, achieving high crossflow velocities with minimal pump speed. A flow restrictor optimizes transmembrane pressure for concentration or diafiltration.

Performance Characteristics

Performance data for Vivaflow® 50, 50R, and 200 cassettes are provided, detailing time to concentrate, average flux, and recovery rates for various sample types and conditions.

Ordering Information

Ordering details for Vivaflow® cassettes and accessories, including product codes and configurations, are listed.

See more

Catalog excerpts

Vivaflow®-1

Product Datasheet Unique, plug and play laboratory crossflow cassettes Product Overview  Rapid sample processing, with ready-to-use cassettes operated by a standard peristaltic pump  Plug and play simplicity, thanks to the unique flip-flow channels that ensure optimal flux  Flexible and modular scalability, with a broad choice of membrane, MWCO and single or multi use options for samples up to 5 L Vivaflow® brings the benefits of tangential flow filtration to research and development laboratories. Operated with a standard peristaltic pump, these ready-to-use cassettes eliminate the cost and complexity of process-scale systems. Ideal for the ultrafiltration and diafiltration of 0.1 to 5 L samples, the unique flip-flow channel design provides plug and play convenience, ensuring optimal crossflow velocities for fast concentr

 Open the catalog to page 1
Vivaflow®-2

Product Information The Vivaflow® range offers a choice of crossflow devices for scientists who need to reliably concentrate or re-buffer aqueous samples with initial volumes of up to 5 L. Unlike other crossflow cassettes on the market, Vivaflow® is a dedicated laboratory product that meets the demand for ease of use without requiring additional, non-standard equipment or significant process optimization. A choice of devices, operated with a standard peristaltic pump, achieve optimal results for every ultrafiltration need: Vivaflow® cassettes lend themselves to a multitude of ultrafiltration...

 Open the catalog to page 2
Vivaflow®-3

Technical Data Vivaflow® 50 Main housing Flow channel Membrane support Membrane seals and O rings Pressure indicator Flow restrictor Overall L | H | W Channel W | H Active membrane area Hold-up volume, cassette Non-recoverable hold-up Pump flow rate Maximum pressure Maximum temperature Operating Conditions * Pressure indicator is available separately (Order no. VFA020) as an optional accessory for Vivaflow® 50 ** SS = stainless steel **

 Open the catalog to page 3
Vivaflow®-4

Working Principle Convenient Diafiltration Vivaflow® cassettes contain an ultrafiltration membrane over which a sample is recirculated using a peristaltic pump (Figure 1). The thin channel flip-flow path provides high crossflow velocities with minimal pump speed requirements of 200 – 400 mL/min. A flow restrictor included with each cassette generates the optimal transmembrane pressure for concentration | diafiltration of the sample, whilst the filtrate is collected in a separate vessel. Ultrafiltration can be stopped as soon as the desired volume is reached by simply turning off the pump. The...

 Open the catalog to page 4
Vivaflow®-5

Components for Operating One to Six Vivaflow® 50 Cassettes Figure 4 Precise scale-up in process speed when using one to four Vivaflow® 50 cassettes. 4x cassettes The modular design of Vivaflow® 50 enables the operation of multiple cassettes in series and parallel (Figure 3 and Table 1). This increases the maximum throughput to up to 3 L and accelerates processing speed in proportion to the membrane area (Figure 4). Concentration Factor Time [hr:min] Figure 3 System components for operating multiple Vivaflow® 50 cassettes. Series interconnectors (Order no. VFA031) T-connectors (Order no. VFA030)...

 Open the catalog to page 5
Vivaflow®-6

Components for Operating One or Two Vivaflow® 50R | 200 Cassettes The maximum throughput of Vivaflow® 50R | 200 can Sample Feed also be increased and processing time reduced| by adding a second cassette to the setup (Figure 5 and Table 2). Figure 5 System components for operating two Vivaflow® 50R | 200 cassettes For Vivaflow® 50R: T-connectors to | from inlets | outlets (Order no. VFA030) For Vivaflow® 200: Y-connector to inlets (Order no. VFA005) Masterflex pump and Easy-Load pump head (Order no. VFP001 | VFP002 and VFA012 | VFA013) Table 2 Sample capacities and system components for operating...

 Open the catalog to page 6
Vivaflow®-8

Performance Performance Characteristics for Vivaflow® 50 Time to concentrate up to 20x at 3 bar inlet pressure, 20°C One Cassette Three Cassettes Recovery (Direct) Yeast, 1.0 mg/mL (S. cerevisiae) 0.2 µm PES Performance Characteristics for Vivaflow® 50R Time to concentrate up to 20x at 3 bar inlet pressure, 20°C 250 mL Initial Volume Average Flux Recovery (Direct) γ Globulins, 1.0 mg/mL (150,000 MW) 100,000 MWCO Hydrosart® Time to concentrate 1 L BSA (1 mg/mL) at 3 bar inlet pressure with 10,000 MWCO Hydrosart® One Vivaflow® 50R Cassette

 Open the catalog to page 8
Vivaflow®-9

Performance Characteristics for Vivaflow® 200 Time to concentrate up to 20x at 3 bar inlet pressure, 20°C 1 L Initial Volume Average Flux Recovery (Direct) BSA, 1.0 mg/mL (66,000 MW) 5,000 MWCO PES 5,000 MWCO Hydrosart γ Globulins, 1.0 mg/mL (average 150,000 MW) 100,000 MWCO PES Yeast, 1.0 mg/mL (S. cerevisiae) 0.2 µm PES Time to concentrate dilute solute from 1 L initial volume at 3 bar inlet pressure with 10,000 MWCO PES BSA, 0.001 mg/mL Time to concentrate BSA (1 mg/mL) from 5 L initial volume at 3 bar inlet pressure with 10,000 MWCO PES BSA, 1.0 mg/mL

 Open the catalog to page 9
Vivaflow®-10

Ordering Information Quantity Pump (240 V), Easy-Load pump head (size 16), tubing, 500 mL sample|diafiltration reservoir, cassette stand, pressure indicator, T connectors and series interconnectors Pump (115 V), Easy-Load pump head (size 16), tubing, 500 mL sample|diafiltration reservoir, cassette stand, pressure indicator, T-connectors and series interconnectors Vivaflow® 50 (includes 2x cassettes with filtrate tube, size 16 peristaltic tubing, flow restrictor and fittings, and 1x series interconnector) Vivaflow® 50 complete system Vivaflow® 50R (includes 1x cassette, filtrate tube, size 16...

 Open the catalog to page 10
Vivaflow®-11

Pump (240 V), Easy-Load pump head (size 16), tubing and 500 mL sample|diafiltration reservoir Pump (115 V), Easy-Load pump head (size 16), tubing and 500 mL sample|diafiltration reservoir Vivaflow® 50R  | 200 complete system Vivaflow® accessories Masterflex Economy Drive variable speed peristaltic pump (230 V) Masterflex Economy Drive variable speed peristaltic pump (115 V) 500 mL sample and|or diafiltration reservoir Masterflex Easy-Load pump head – size 16 Masterflex Easy-Load pump head – size 15 Vivaflow® 50 accessories for operating 2-6 cassettes T-connectors for running 2 stacks Series interconnectors...

 Open the catalog to page 11

All Sartorius AG catalogs and technical brochures

  1. Flexboy 2D Bags

    55  Pages

  2. iQue® 3

    7  Pages

  3. Vacusart

    2  Pages

  4. Filter Papers

    36  Pages

  5. Cubis® II

    12  Pages

  6. Arium® Mini

    11  Pages

  7. Midi Plus

    4  Pages

  8. Practum®

    8  Pages

  9. Entris®

    4  Pages

  10. Quintix®

    12  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.