1. Catalogs
  2. Sartorius AG
  3. The Sterisart® Universal Pump

The Sterisart® Universal Pump

The Sterisart® Universal Pump

The Sterisart® Universal Pump

Product catalog summary
Overview
The Sterisart® Universal Pump is designed for sterility testing of pharmaceutical products, ensuring compliance with international pharmacopeias. It is a successor to the 16413 peristaltic pump and is compatible with the Sterisart® NF sterility test system.

Key Features
  • Material and Design: Made of stainless steel for chemical compatibility and durability, suitable for clean rooms and isolators.
  • Compact and User-Friendly: Designed to save space with easy handling and maintenance.
  • Safety and Reliability: Closed chassis design prevents contamination in clean environments.
  • Versatile Design: Available in two versions for different installation needs.
  • Special Software: High-end version includes software for guided operation and data logging.

Technical Specifications
  • Flow Rate: 70 – 650 ml/min
  • Power Requirements: 100 – 240 VAC, 50 – 60 Hz
  • Dimensions: 336 × 260 × 210 mm (basic version)
  • Weight: Approx. 13.5 kg (basic version), 14.6 kg (upgraded version)

Ordering Information
The pump is available in basic and upgraded versions, with various accessories such as ampoule tongs, holding rings, and software for enhanced functionality.

Conclusion
The Sterisart® Universal Pump offers a reliable and efficient solution for sterility testing, with features that enhance safety, ease of use, and compliance with regulatory standards.
See more

Catalog excerpts

The Sterisart® Universal Pump-1

The Sterisart Universal Pump ® The Right Equipment for Your Sterility Test

 Open the catalog to page 1
The Sterisart® Universal Pump-3

The Sterisart® Universal Pump - Convenience & Confidence Combined An intelligent concept for reliable results International pharmacopeias require the complete sterility of pharmaceutical products, such as parenteralia, that are injected into the blood stream or that otherwise enter the body below the skin surface. As a manufacturer of such products, you are required to supply proof of the sterility of each final product batch. Sterility testing by membrane filtration is the method of choice for all filterable sterile pharmaceuticals. The tests are typically performed using pre-sterilised, closed,...

 Open the catalog to page 3
The Sterisart® Universal Pump-4

Features Increased Safety and Reliability Special Software A unique motor principle has resulted in a closed pump chassis design, eliminating the need for ventilation of the motor. Therefore, the pump will not release any particles or microbes into cleanroom or isolator environments or cause turbulence in laminar-flow areas. This results in increased safety and reliability. The special software of the high-end version 16420 guides the user by individual menu prompts. For instance, two different programs can be selected currently (manual operating mode and manual operating mode with data collection)....

 Open the catalog to page 4
The Sterisart® Universal Pump-5

Technical Specifications Pump flow rate Power requirements Power consumption Pump with holding ring for bottles, container (W × D × H) Weight Basic version 16419 Upgraded version 16420 with display | user software Materials Base plate, lever, bow, rotor Housing, connection port, housing control unit, stand, fastening arm, holder ring for bottles Operating display Connecting cable Connector control unit Tarnish chrome Connector grommet Container for draining, plastic sleeve for lever Seals, gaskets, adhesiv

 Open the catalog to page 5
The Sterisart® Universal Pump-6

Ordering Information Sterisart® Universal Pump and Accessories Order Number Sterisart® Universal pump, basic version Sterisart Universal pump, upgraded version with display | user software Ampoule tongs Holding ring for bottles Drain tubing Ampoule breaker Foot switch Plastic sleeve for lever Separate control unit Extension cable control unit Clamp for control unit Serial cable Cover for container draining (Sterisart sterility test units) Cover for container draining (Millipore sterility test units) Adapter draining container for Sterisart® units on Millipore pump Cover for electrical connectors...

 Open the catalog to page 6
The Sterisart® Universal Pump-7

Sterisart® NF sterility testing solutions Order Number Sterisart® system for liquids in closed, large volume containers such as bottles Sterisart system, with septum, for liquids in closed, large volume containers such as bottles Sterisart CA for liquids in closed, large volume containers such as bottles Sterisart system for liquids in open containers such as ampoules Sterisart system, with septum, for liquids in open containers such as ampoules Sterisart CA for liquids in open containers such as ampoules Sterisart system for liquids in closed, small volume containers such as vials Sterisart...

 Open the catalog to page 7
The Sterisart® Universal Pump-8

Germany Sartorius Lab Instruments GmbH & Co. KG Otto-Brenner-Strasse 20 37079 Goettingen Phone +49 551 308 0 F or further contacts, visit www.sartorius.com Specifications subject to change without notice. Copyright Sartorius Lab Instruments GmbH & Co. KG. Status: 11 | 2020

 Open the catalog to page 8

All Sartorius AG catalogs and technical brochures

  1. Flexboy 2D Bags

    55  Pages

  2. iQue® 3

    7  Pages

  3. Vivaflow®

    12  Pages

  4. Vacusart

    2  Pages

  5. Filter Papers

    36  Pages

  6. Cubis® II

    12  Pages

  7. Arium® Mini

    11  Pages

  8. Midi Plus

    4  Pages

  9. Practum®

    8  Pages

  10. Entris®

    4  Pages

  11. Quintix®

    12  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.