Overview: The document outlines the technical specifications and operational guidelines for the IM6 series load switches and disconnectors used in medium voltage switchboards, emphasizing safety and reliability.
Specifications: The IM6 switches are encased in an epoxy resin enclosure filled with SF6 gas at 150kPa, adhering to IEC 60265-1 standards. They feature a rotary shaft mechanism with positions for closed, open, or earthed states to prevent incorrect operations.
Characteristics: The IM6 series boasts a long service life, maintenance-free active parts, operational safety, and low over-voltage levels. They utilize SF6 gas for insulation and breaking, meeting IEC standards for sealed pressure systems.
Applications: These switches are used in System-6 type medium voltage switchboards, which are modular, compact, and arc-proof, suitable for complex configurations and equipped with mechanical interlocks. They comply with CEI EN-62271-200 and IEC 62271-200 standards.
Testing and Quality Assurance: The IM6 devices have passed type tests in official laboratories per IEC and GOST standards. A rigorous quality control system ensures high production quality, with comprehensive mechanical and electrical testing before supply.
Electrical Characteristics: The document details electrical parameters such as rated voltage, short-time withstand current, and making and breaking capacities for voltage levels of 12kV, 17.5kV, 24kV, and 36kV.
Operating Mechanisms: Descriptions of manual (KS), motorized (KS-M), and precharged spring (KP) systems are provided, ensuring reliable operation independent of the operator.
Specifications and Components:
  • Earth Key Interlocks: Ensures safety by freeing the key in the closed position.
  • Auxiliary Contacts: Available for Line/Earth and fuse blow-up scenarios for added safety.
  • Tripping and Closing Coils: Available in various voltages for operational flexibility.
  • Voltage Indication: Devices indicate voltage presence, enhancing safety.
  • Selector 0-1: A simple switch for operational control.
  • Connection Terminal Box: Ensures secure and organized connections.
  • Fuses for Auxiliary Circuit Protection: Protects against overcurrent.
  • Operating Monitor Card: Monitors and controls motor operations.
  • Motoreducer for Remote Operation: Allows remote control, available in multiple voltage options.
Dimensions and Fixing:
  • Dimensions: Detailed measurements ensure compatibility and proper installation.
  • Fixing with Screw M10x45: Standard method for secure installation.
  • Capacitive Dividers: Ensure efficient operation by dividing electrical capacities.
Standards and Recommendations:
  • Continuous Development: Information is subject to revision due to ongoing material and standards development.
Optional and Standard Accessories:
  • Standard Accessories: Included as part of the basic package.
  • Optional Accessories: Can be added based on specific requirements.
Notes:
  • Non-Provided Items: Indicated by 'NF', not included in the package.
  • Special Notes: Certain dimensions and specifications have specific configuration notes.
See more

Catalog excerpts

switches IM6 SF6 insulated 12-36KV-1

untitled tr.row {} td.cell {} div.block {} div.paragraph {} .font0 { font:23.00pt "Arial", sans-serif; } Interruttore di manovra-sezionatore On-load switch Interrupteur

 Open the catalog to page 1
switches IM6 SF6 insulated 12-36KV-2

tr.row {} td.cell {} div.block {} div.paragraph {}

 Open the catalog to page 2
switches IM6 SF6 insulated 12-36KV-3

Caractristique: Les interrupteurs et sectionneurs IM6 utilisent l'hexafluorure de soufre (SF6) pour l'isolement et la coupure. Les parties actives sont places dans une enveloppe en mati驨re isolante scelle vie, r頩pondant aux standards IEC annexe EE pour les systmes pression scell蠩e. Les appareils IM6 ont des caractristiques remarquables: - Longue dure de vie - Absence d'entretien des parties actives - S騩curit de fonctionnement - Niveau de surtension trs faible Principe de fonctionnement: Charateristics: Les interrupteurs s騩rie IM6 sont constitues par une enveloppe moule en rsine 驩poxy, rempli...

 Open the catalog to page 3
switches IM6 SF6 insulated 12-36KV-4

Tableau de moyenne tension equip avec interrupteur en SF6 Vista interna scomparto equipaggiatoconsezionatore/interruttore in SF6 Medium voltage switchboard equipped with SF6 on load switch Vista interna scomparto equipaggiato con sezionatore-fusibili IM6P-TF Internal panel view equipped withIM6P-TF switch Vue int訩rieure de la cellule quipe par sectionneurIM6P-TF >

 Open the catalog to page 4
switches IM6 SF6 insulated 12-36KV-5

Rapporti di prova: Gli apparecchi IM6 hanno positivamente superato in laboratori ufficiali tutte le prove di tipo in accordo alle Norme internazionali IEC e GOST. Normative: Il sistema di qualit: Test report: Rispondenza norme: - IEC 62271-102 - IEC 62271-105 - IEC 265.1 Il sistema di controllo qualit assicura che l'intero processo di produzione mantenga un livello qualitativamente alto e costante. Prima della fornitura, ciascun quadro ࠨ sottoposto in fabbrica a minuziose prove e controlli, sia di tipo meccanico sia di tipo elettrico, incluse le prove di accettazione previste dalle normative...

 Open the catalog to page 5
switches IM6 SF6 insulated 12-36KV-6

tr.row {} td.cell {} div.block {} div.paragraph {} .font0 { font:4.00pt "Arial", sans-serif; } .font1 { font:5.00pt "Arial", sans-serif; } .font2 { font:8.00pt "Microsoft Sans Serif", sans-serif; } .font3 { font:10.00pt "Microsoft Sans Serif", sans-serif; } .font4 { font:12.00pt "Microsoft Sans Serif", sans-serif; } .font5 { font:7.00pt "Times New Roman", serif; } .font6 { font:11.00pt "Times New Roman", serif; } Caratteristiehe elettriehe Eleetrieal eharaeteristies Caratteristique elecriques Tensione nominale kV 12 17,5 24 36 Rated voltage Tension nominale Tensione nominale di tenuta alla frequenza...

 Open the catalog to page 6
switches IM6 SF6 insulated 12-36KV-7

Earth switch: La manoeuvre est execute comme pour l'interrupteur. The operation is the same of the line switch. Sectionneur de M.A.T.: La manovra avviene come per il comando dell'interruttore. L'nergie n驩cessaire pour la manuvre est obtenue par compression d'uneressort avec un levier, qui ܠ passage de point mort provoque la fermeture del'interrupteur.La rotation du levier dans le senscontraire recharge le ressort, qui passage de point mort provoque l'ouverture. La vitesse des manuvres de fermeture et d'ouverture est indܩpendante del'oprateur. Sezionatore di terra: The necessary energy to operate...

 Open the catalog to page 7
switches IM6 SF6 insulated 12-36KV-8

La manuvre est la meme dܩcrit pour le commande KS. Sectionneur de M.A.T.: The operation is the same as described for KS operating mechanism. Earth switch: Le principe de fonctionnement est le mme de la commande KS, mais la manuvre ꜠ distance est possible par un moteur. Le temps de fonctionnement du moteur pour le changement d'tat est infrieur 驠 7 secondes. > Commande KS-M Interrupteur de ligne: La manovra come quella descritta nel comando KS. Commande STANDARD MOTORISEE passage de point mort. > Sezionatore di terra: Functioning concept is the same as the manual KS operating mechanism, it can...

 Open the catalog to page 8
switches IM6 SF6 insulated 12-36KV-9

La manuvre est la meme dܩcrit pour le commande KS. Sectionneur de M.A.T.: La manovra come quella descritta per il per il comando KS. > KPOperating mechanism PRECHARGED SPRING operating mechanism with hook to open and close. The operator charges manually the springs which store necessary energy for closingand openingwith the mechanical selectoror through the tripping and closing coils. Indication of spring chargedis placed on the front of the operating mechanism. When the operating mechanism is installedon theswitch-fuse, the opening can be caused also at the blow up of one single fuse. > Line...

 Open the catalog to page 9
switches IM6 SF6 insulated 12-36KV-10

tr.row {} td.cell {} div.block {} div.paragraph {} .font0 { font:9.00pt "Arial", sans-serif; } .font1 { font:25.00pt "Arial", sans-serif; } .font2 { font:8.00pt "Microsoft Sans Serif", sans-serif; } .font3 { font:10.00pt "Microsoft Sans Serif", sans-serif; } .font4 { font:12.00pt "Microsoft Sans Serif", sans-serif; } .font5 { font:7.00pt "Times New Roman", serif; } .font6 { font:8.00pt "Times New Roman", serif; } .font7 { font:9.00pt "Times New Roman", serif; } .font8 { font:11.00pt "Times New Roman", serif; } Aoeessori Accessories Accessoires Posizione Position Description ■ 1 Desorizione Description...

 Open the catalog to page 10
switches IM6 SF6 insulated 12-36KV-11

Accessori Accessories Accessoires > 11 size="-1">

 Open the catalog to page 11
switches IM6 SF6 insulated 12-36KV-12

G A 18,5 18,5 18,5 54,5 kV 185,5 185,5 185,5 373,5 1217,524 36 F 37,5 37,5 37,5*(3) E 295 295 295*(3) > fissaggio con vite M10x45 fixing with screw M 10x45 fixsage avec vis M 10x45 D > divisori capacitivi 13 13 13 13 > capacitive dividers diviseur capacitives fronte quadro front pannel front cellule C 230 230 230*(3) > IM6S - IM6P B 870 870 870*(3) A kV 248 248 248373,5 W 1217,524 36 *(1) *(1)150 150 > fissaggio con vite M10x45 fixing with screw M 10x45 fixsage avec vis M 10x45 fronte quadro front pannel front cellule divisori capacitivi IM6S-TD capacitive dividers diviseur capacitives

 Open the catalog to page 12
switches IM6 SF6 insulated 12-36KV-13

B 870 870 870*(3) A kV 185,5 185,5248373,5 V W 1217,524 36 292 292 442 534 *(1) *(1)150 150 > fissaggio con vite M10x45 fixing with screw M 10x45 fixsage avec vis M 10x45 fronte quadro front pannel front cellule divisori capacitivi capacitive dividers diviseur capacitives IM6P-TF - IM6S-TF * Nota - Note - Note > Quote fissaggio traversa apparecchio On-load switch cross-brace fixed dimension Dimension de fissage de la traverse du interrupteur >