Group: SANYO DENKI CO.,LTD.
Catalog excerpts
DC Fan ■ Features Low Noise Compared to our current model,(1) noise level has been reduced by 3 dB(A). High Cooling Performance While featuring low noise, the maximum airflow and maximum static pressure have increased by 33% and 70%,(2) respectively, compared to the current model.(1) Energy Saving Power consumption has been reduced by 35% compared to the current model.(1) Rich Lineup The lineup offers four different rotational speeds for each of 12/24/48 V rated voltages. The broad lineup of fans enables you to choose the right fan best suited to your applications. (1) Current model: 140 × 140 × 38 mm San Ace 140 9P type DC Fan (model: 109P1448H101). (2) For models 9RA1412P1G001, 9RA1424P1G001, and 9RA1448P1G001. The models listed below have ribs and pulse sensors with PWM control function. For models without ribs, append "1" to the end of model numbers. Model no. Operating voltage range [V] The models listed below have ribs and pulse sensors. For models without ribs, append "1" to the end of model numbers. Model no. Operating voltage range [V] Models with the following sensor specifications are also available as options: ■ Common Specifications □ Material □ Expected life Frame: Plastic (Flammability: UL 94V-0), Impeller: Plastic (Flammability: UL 94V-0) Refer to specifications (L10 life: 90% survival rate for continuous operation in free air at 60°C, rated voltage) Expected life at 40°C is for reference only. □ Motor protection function Locked rotor burnout protection, Reverse polarity protection 50/60 Hz, 500 VAC, for 1 minute (between lead wire conductors and frame) 10 MΩ min. at 500 VDC (between lead wire conductors and frame) □ Sound pressure level (SPL) A-weighted sound pressure level (SPL) at 1 m away from the air inlet. Refer to specifications (Non-condensing) + Red − Black Sensor Yellow Control Brown (For models without PWM control function, there is n
Open the catalog to page 1■ Airflow - Static Pressure Characteristics Operating voltage range Static pressure Static pressure Static pressure Operating voltage range Static pressure Operating voltage range Static pressure Static pressure Static pressure Static pressure Operating voltage range Static pressure Static pressure Static pressure Static pressure Static pressure Static pressure Static pressure
Open the catalog to page 2140 × 140 × 38 mm ■ PWM Duty - Speed Characteristics Example Voltage: 12 VDC PWM frequency: 25 kHz ■ PWM Input Signal Example Input signal waveform PWM duty cycle (%) = T ×100 PWM frequency 25 (kHz) = T Current source (Isource) = 1.0 mA max. (when control voltage is 0 V) Current sink (Isink) = 1.0 mA max. (when control voltage is 5.25 V) When the PWM control terminal is open, the fan speed is the same as the speed at 100% PWM duty cycle. The PWM signal can be used with open collector or drain input. Note that when using an open collector or drain input, or inputting a different voltage or...
Open the catalog to page 3■ Dimensions (unit: mm) (Ribbed frame with pulse sensor with PWM control function) 140±0.8 Airflow direction Rotating direction ■ Reference Dimensions of Mounting Holes and Vent Opening (unit: mm) Inlet side ■ Options Finger guards Model no.: 109-719, 109-719H ●Please read the "Safety Precautions" on our website before using the product. ●The products shown in this catalog are subject to Japanese Export Control Law. Diversion contrary to the law of exporting country is prohibited. ●For protecting fan bearings against electrolytic corrosion near strong electromagnetic noise sources, we...
Open the catalog to page 4All SANYO DENKI EUROPE catalogs and technical brochures
-
SAN_ACE_120AD_120x25_ACDC
4 Pages
-
San_Ace_40LG_40x28_Long_Life
4 Pages
-
STEPPING MOTOR WITH ENCODER
32 Pages
-
Company Profile 2023
8 Pages
-
SANMOTION G
80 Pages
-
San_Ace_160ADW51
4 Pages
-
San_Ace_160ADA51
4 Pages
-
San_Ace_120ADAW38
4 Pages
-
San_Ace_120ADA38
4 Pages
-
San Ace 80x38 - 9RA
4 Pages
-
San Ace 2022
632 Pages
-
SANMOTION F2
84 Pages
-
PRODUCT INFORMATION
52 Pages
-
San Ace 100W
4 Pages
-
San Ace 172AD
4 Pages
-
San Ace 120 - 9RA
4 Pages
-
San Ace 92 - 9RA
4 Pages
-
San Ace 80 - 9RA
4 Pages
-
San Ace 60 - 9RA
4 Pages
-
San Ace 133W
4 Pages
-
SANMOTION_R_3E_AC400V_550W-55kW
128 Pages
-
SANMOTION K
28 Pages
-
SANMOTION C _ SMC100 _ECAT
12 Pages
-
SANMOTION F5
128 Pages
-
SANMOTION R
4 Pages
-
San Ace Controller
4 Pages
-
San Ace 97W
4 Pages
-
SANMOTION R 100/200V General Catalog
172 Pages
-
SANMOTION_R_AD_48VDC_20-200W
36 Pages
-
Model No. PB
104 Pages
-
SANMOTION_Linear
4 Pages
-
SANMOTION_C_EtherCAT
16 Pages
-
SERVOMOTOR_R2_14mm_2W
2 Pages
-
DC SERVO SYSTEMS
36 Pages
-
3 PHASE STEPPER - SANMOTION F3
12 Pages
-
SANUPS HYBRID UPS E11A
8 Pages
-
A11J
12 Pages
Archived catalogs
-
San Ace 150W
4 Pages
-
SANMOTION_R_3E_AD_100-200V_30W-30kW
160 Pages
-
San Ace 2018 ver. 2
576 Pages
-
5-phase stepping MOTOR
128 Pages
-
2-PHASE STEPPING SYSTEMS
100 Pages
-
SANMOTION_C
12 Pages
-
SERVOMOTOR_R2_275mm_37kW
2 Pages
-
SANMOTION_R_100-200V_30W-1kW
40 Pages