Overview: The document outlines the specifications and features of the A11J Online UPS, emphasizing its efficiency, reliability, and expandable capacity. It is tailored for high power factor devices and offers easy maintenance with a compact design.
Specifications: The UPS is available in capacities of 5 kVA (4.5 kW), 10 kVA (9 kW), 15 kVA, and 20 kVA, supporting both single and parallel redundant operations. It boasts a high efficiency of 93% and is UL and CE certified for models with 200 V AC input and output.
Features: Key features include a periodic automatic battery operation test, a front removable battery pack, and an inverter for easy maintenance. It also has a built-in maintenance bypass circuit, except for UL/CE certified models. An LCD display panel is included for monitoring operational status.
Mounting Options: The UPS can be mounted vertically or in a 19-inch rack with optional support rails, with a compact 3U size for the 5 kVA unit.
Power Supply and Output: The UPS provides a true online power supply synchronized with the commercial power source, featuring a forced air cooling system and a high-frequency PWM inverter system. The rated voltage is adjustable between 200V and 240V, with a frequency of 50Hz or 60Hz.
Battery and Maintenance: It uses small-sized sealed lead-acid batteries with a runtime of 5 to 10 minutes, depending on the model, and an expected service life of 5 years. It operates in temperatures from 0 to 40 degrees Celsius with relative humidity between 20% and 90%.
Options and Accessories: Optional accessories include a LAN interface card for monitoring and SANUPS software for enhanced reliability. Various models and configurations are available to meet different needs.
Battery Cabinet Dimensions and Mass: Specifications for battery cabinets include dimensions, mass, and battery capacity. For example, Model A11J502 measures 435 mm in width, 700 mm in depth, and 130 mm in height, weighing 49 kg (108 lbs). Optional battery compositions are available for different durations.
Rack Support Rails and Transformer Box: Rack support rails are designed for 19-inch racks, with dimensions provided for various models. The transformer box converts voltage from 200 V to 100 V, integrating a transformer, breaker, and receptacle. Note that the battery box, battery cabinet, and transformer box are not UL/CE certified.
Installation and Usage Guidelines: It is advised to read the operation manual carefully before installation and use. Special considerations are necessary for applications related to human life, such as medical equipment and public safety systems. Consultation with the company is recommended for specialized applications.
Contact Information: Contact details for Sanyo Denki offices in various countries are provided for inquiries and consultations.
Eco Products: Sanyo Denki's ECO PRODUCTS aim to minimize environmental impact throughout the product lifecycle. Products meeting specific environmental criteria are accredited as ECO PRODUCTS.
Highly Reliable and Efcient Online UPS Battery backup time Output capacity *1 3U type with a load factor of 0.8. *2 4U type with a load factor of 0.75. Optional battery *3 There are some restrictions on the combination with the installation method and output capacity. *UL/CE certified models are available only for 200 V AC input and output and 5-minute backup time. See the model list on page 6. Parallel redundant operation Single unit operation and parallel operation Output capacity Output capacity Highly Reliable Online UPS Achieved a High Efciency of 93%.*4 1 High Efciency 2 High Reliability...
Open the catalog to page 21 High Efciency High 93% efciency (with the 5 kVA single unit model). Reduces running cost and helps conserve energy. Commercial power supply 2 High Reliability Periodic automatic battery operation tests ensure reliable operation during a power outage. *You can select the frequency of the battery operation test from 1, 3 and 6 months. The factory setting is 6 months. Start operation test Normal operation Commercial power supply Rectier Booster Check battery power supply Periodic check Commercial power supply Rectier Booster Return to normal operation *If deterioration in battery performance is...
Open the catalog to page 34 Space-saving Design The compact 3U size of the 5 kVA UPS unit (for 5-minute backup) allows you to mount it in an EIA 19-inch rack. 5 Able to Supply Power to High Power Factor Devices 0.9 load power factor enables the unit to supply power to high power factor devices such as servers. Output capacity of 5 18 kW max. UL/CE certified unit: 17 kW max. 6 Easy Maintenance Front removable battery pack and inverter provide easy maintenance. *You can replace the battery pack without interrupting inverter power supply operation. The built-in maintenance bypass circuit allows you to perform maintenance...
Open the catalog to page 4External View Inverter ON/OFF Switch Input LED Output LED Alarm LED Input Switch Menu Operation Switch Inverter ON/OFF Switch Maintenance Bypass Switch (Inside Cover) * This is not available for UL/CE certified units Model: A11J502****T Terminal Block Type Optional Battery Connector Output Receptacle (NEMA L6-30R) External Control Terminal (EPO and Remote ON/OFF) Card Interface Optional Battery Connector Unit-to-Unit Interface Output Receptacle Breaker (for IEC-C13) Optional Slot Contact Signal Interface External Control Terminal (EPO and Remote ON/OFF) Card Interface PC Interface I/O Terminal...
Open the catalog to page 5Item Feature Single / Terminal block Rated output capacity (Apparent power/Active power) Single / NEMA Plug Capacity increasable (with 20 kVA Power Distribution Unit) Power supply system True online power supply synchronized with commercial power source Cooling system Inverter system Capacity increasable / Parallel redundantable*1 VCCI Class A Rated voltage 200 V, 208V, 220V, 230V, 240V (User settable. Factory setting: 200V) (Acceptable voltage range: -40% to +15%) *3 Rated frequency 50Hz / 60Hz (Selectable Auto-detect or Constant frequency *4 Factory setting: Auto-detect) Power factor Min. 0.95...
Open the catalog to page 6Item Rated output capacity (Apparent power/Active power) Capacity increasable (with 20 kVA Power Distribution Unit) Power supply system System True online power supply synchronized with commercial power source Cooling system Inverter system Rated voltage Rated frequency AC input 100 V or 200 V (Swith at terminal) Acceptable voltage range: -35% to +15% *1 50Hz / 60Hz (Selectable Auto-detect or Constant frequency *2 Factory setting: Auto-detect) 200 V Acceptable voltage range: -40% to +15% *1 Power factor Min. 0.95 (At rated input voltage and input voltage distorsion rate under 1%) Max. capacity...
Open the catalog to page 7Specications of External Connection Terminal, Wiring Wire, etc. Model Backup time 5 min. Input breaker capacity *1 Input: M6 Output: M6 NEMA L6-30R NEMA L6-20R Input Output voltage voltage 8 mm2 (size AA), 14 mm2 (size C) 14 mm2 (size AA), 38 mm2 (size C) Transfer signal: (1) Contact signal: DSUB15 (female) xing screw M3 (2) PC interface: DSUB9 (male) xing screw #4-40UNC Remote control: Spring clamp terminal block Applicable wires: Single wire: AWG28 to 18, twisted wire: AWG22 to 20 UL/CE certied unit Model Backup time 5 min. I/O connection terminal / plug Input wire *1 Output wire *1 Input breaker...
Open the catalog to page 8External Dimensions Backup Time 5 Minutes, Single Unit/Floor Type Model Dimensions Width Size Dipth*1 Height Mass*3 Model Dimensions Width Size Dipth*1 Height Mass*3 Model Dimensions Width Size Dipth*1 Height Mass*3 Model Dimensions Width Size Dipth*1 Height Mass*3 Backup Time 5 Minutes, Single Unit/Floor Type, UL/CE certied unit Model Dimensions Width Size Dipth*1 Height Mass*3 Backup Time 5 Minutes, Rack Mounting A11J502SA002RM MAIN MCCB MAIN MCCB OUTPUT ALARM OUTPUT ALARM MAIN MCCB INPUT OUTPUT ALARM MAIN MCCB OUTPUT ALARM MAIN MCCB INPUT OUTPUT ALARM MAIN MCCB MAIN MCCB MAIN MCCB MAIN MCCB...
Open the catalog to page 9External Dimensions Backup Time 10 Minutes, Single Unit/Floor Type Model Dimensions Width Size Dipth*1 Height Mass Model Dimensions Width Size Dipth*1 Height Mass Model Dimensions Width Size Dipth*1 Height Mass Model Dimensions Width Size Dipth*1 Height Mass Backup Time 5 Minutes, Rack Mounting Model Dimensions Width (W) Size Dipth(D)*1 (mm) Height (H) Mass (kg) *1: UPS unit + cable cover/terminal block *2: The second and the following UPS units are not equipped with an LCD display panel. Rack Mounting Vertically Mounting OUTPUT ALARM MAIN MCCB 700 (27.56) INPUT OUTPUT ALARM MAIN MCCB MAIN MCCB...
Open the catalog to page 10Options Battery Box Dimensions, Mass (Rackmounting exclusive use) Dimensions Size Width Battery Cabinet Dimensions, Mass Mass Size Width Rack Support Rails Dimensions Rack mounting dimension A set of left and right rails The gure shows the left rail Rack mounting dimension 688 to 798 (27.09 to 31.42) Rack mounting dimension Rack mounting dimension A set of left and right rails The gure shows the left rail A set of left and right rails The gure shows the left rail Transformer Box This is a rack-mounting transformer unit that can be mounted in a 19-inch rack and that can convert the voltage from...
Open the catalog to page 114 Pages
4 Pages
4 Pages
32 Pages
8 Pages
80 Pages
4 Pages
4 Pages
4 Pages
4 Pages
4 Pages
4 Pages
632 Pages
84 Pages
52 Pages
4 Pages
4 Pages
4 Pages
4 Pages
4 Pages
4 Pages
4 Pages
128 Pages
28 Pages
12 Pages
128 Pages
4 Pages
4 Pages
4 Pages
172 Pages
36 Pages
104 Pages
4 Pages
16 Pages
2 Pages
36 Pages
12 Pages
8 Pages
12 Pages
4 Pages
576 Pages
100 Pages
128 Pages
2 Pages
40 Pages
160 Pages