A11J - 12 Pages

Add to MyDirectIndustry favorites
A11J

Catalog excerpts

Highly Reliable and Efcient Online UPS Battery backup time Output capacity *1 3U type with a load factor of 0.8. *2 4U type with a load factor of 0.75. Optional battery *3 There are some restrictions on the combination with the installation method and output capacity. *UL/CE certified models are available only for 200 V AC input and output and 5-minute backup time. See the model list on page 6. Parallel redundant operation Single unit operation and parallel operation Output capacity Output capacity Highly Reliable Online UPS Achieved a High Efciency of 93%.*4 1 High Efciency 2 High...

 Open the catalog to page 2

1 High Efciency High 93% efciency (with the 5 kVA single unit model). Reduces running cost and helps conserve energy. Commercial power supply 2 High Reliability Periodic automatic battery operation tests ensure reliable operation during a power outage. *You can select the frequency of the battery operation test from 1, 3 and 6 months. The factory setting is 6 months. Start operation test Normal operation Commercial power supply Rectier Booster Check battery power supply Periodic check Commercial power supply Rectier Booster Return to normal operation *If deterioration in battery performance...

 Open the catalog to page 3

4 Space-saving Design The compact 3U size of the 5 kVA UPS unit (for 5-minute backup) allows you to mount it in an EIA 19-inch rack. 5 Able to Supply Power to High Power Factor Devices 0.9 load power factor enables the unit to supply power to high power factor devices such as servers. Output capacity of 5 18 kW max. UL/CE certified unit: 17 kW max. 6 Easy Maintenance Front removable battery pack and inverter provide easy maintenance. *You can replace the battery pack without interrupting inverter power supply operation. The built-in maintenance bypass circuit allows you to perform...

 Open the catalog to page 4

External View Inverter ON/OFF Switch Input LED Output LED Alarm LED Input Switch Menu Operation Switch Inverter ON/OFF Switch Maintenance Bypass Switch (Inside Cover) * This is not available for UL/CE certified units Model: A11J502****T Terminal Block Type Optional Battery Connector Output Receptacle (NEMA L6-30R) External Control Terminal (EPO and Remote ON/OFF) Card Interface Optional Battery Connector Unit-to-Unit Interface Output Receptacle Breaker (for IEC-C13) Optional Slot Contact Signal Interface External Control Terminal (EPO and Remote ON/OFF) Card Interface PC Interface I/O...

 Open the catalog to page 5

Item Feature Single / Terminal block Rated output capacity (Apparent power/Active power) Single / NEMA Plug Capacity increasable (with 20 kVA Power Distribution Unit) Power supply system True online power supply synchronized with commercial power source Cooling system Inverter system Capacity increasable / Parallel redundantable*1 VCCI Class A Rated voltage 200 V, 208V, 220V, 230V, 240V (User settable. Factory setting: 200V) (Acceptable voltage range: -40% to +15%) *3 Rated frequency 50Hz / 60Hz (Selectable Auto-detect or Constant frequency *4 Factory setting: Auto-detect) Power factor Min....

 Open the catalog to page 6

Item Rated output capacity (Apparent power/Active power) Capacity increasable (with 20 kVA Power Distribution Unit) Power supply system System True online power supply synchronized with commercial power source Cooling system Inverter system Rated voltage Rated frequency AC input 100 V or 200 V (Swith at terminal) Acceptable voltage range: -35% to +15% *1 50Hz / 60Hz (Selectable Auto-detect or Constant frequency *2 Factory setting: Auto-detect) 200 V Acceptable voltage range: -40% to +15% *1 Power factor Min. 0.95 (At rated input voltage and input voltage distorsion rate under 1%) Max....

 Open the catalog to page 7

Specications of External Connection Terminal, Wiring Wire, etc. Model Backup time 5 min. Input breaker capacity *1 Input: M6 Output: M6 NEMA L6-30R NEMA L6-20R Input Output voltage voltage 8 mm2 (size AA), 14 mm2 (size C) 14 mm2 (size AA), 38 mm2 (size C) Transfer signal: (1) Contact signal: DSUB15 (female) xing screw M3 (2) PC interface: DSUB9 (male) xing screw #4-40UNC Remote control: Spring clamp terminal block Applicable wires: Single wire: AWG28 to 18, twisted wire: AWG22 to 20 UL/CE certied unit Model Backup time 5 min. I/O connection terminal / plug Input wire *1 Output wire *1 Input...

 Open the catalog to page 8

External Dimensions Backup Time 5 Minutes, Single Unit/Floor Type Model Dimensions Width Size Dipth*1 Height Mass*3 Model Dimensions Width Size Dipth*1 Height Mass*3 Model Dimensions Width Size Dipth*1 Height Mass*3 Model Dimensions Width Size Dipth*1 Height Mass*3 Backup Time 5 Minutes, Single Unit/Floor Type, UL/CE certied unit Model Dimensions Width Size Dipth*1 Height Mass*3 Backup Time 5 Minutes, Rack Mounting A11J502SA002RM MAIN MCCB MAIN MCCB OUTPUT ALARM OUTPUT ALARM MAIN MCCB INPUT OUTPUT ALARM MAIN MCCB OUTPUT ALARM MAIN MCCB INPUT OUTPUT ALARM MAIN MCCB MAIN MCCB MAIN MCCB MAIN...

 Open the catalog to page 9

External Dimensions Backup Time 10 Minutes, Single Unit/Floor Type Model Dimensions Width Size Dipth*1 Height Mass Model Dimensions Width Size Dipth*1 Height Mass Model Dimensions Width Size Dipth*1 Height Mass Model Dimensions Width Size Dipth*1 Height Mass Backup Time 5 Minutes, Rack Mounting Model Dimensions Width (W) Size Dipth(D)*1 (mm) Height (H) Mass (kg) *1: UPS unit + cable cover/terminal block *2: The second and the following UPS units are not equipped with an LCD display panel. Rack Mounting Vertically Mounting OUTPUT ALARM MAIN MCCB 700 (27.56) INPUT OUTPUT ALARM MAIN MCCB MAIN...

 Open the catalog to page 10

Options Battery Box Dimensions, Mass (Rackmounting exclusive use) Dimensions Size Width Battery Cabinet Dimensions, Mass Mass Size Width Rack Support Rails Dimensions Rack mounting dimension A set of left and right rails The gure shows the left rail Rack mounting dimension 688 to 798 (27.09 to 31.42) Rack mounting dimension Rack mounting dimension A set of left and right rails The gure shows the left rail A set of left and right rails The gure shows the left rail Transformer Box This is a rack-mounting transformer unit that can be mounted in a 19-inch rack and that can convert the voltage...

 Open the catalog to page 11

f ^^^r^ Sanyo Denki's ECO PRODUCTS are designed with the concept of lessening impact on the environment in the process from product development to waste.The product units and packaging materials are designed for reduced environmental impact.We have established our own assessment criteria on the environmental impacts applicable to all ECO PRODUCTS processes,ranging from design to manufactureThose products that satisfy the criteria are accredited as ECO PRODUCTS. Notes when investigating use of this product in your applications • Before starting installation, assembling and use, read the...

 Open the catalog to page 12

All SANYO DENKI EUROPE catalogs and technical brochures

  1. SANMOTION K

    4 Pages

  2. SANMOTION C

    2 Pages

  3. SANMOTION F5

    128 Pages

  4. SANMOTION F2

    84 Pages

  5. SANMOTION R

    4 Pages

  6. San Ace 150W

    4 Pages

  7. San Ace 97W

    4 Pages

  8. San_Ace_2019_E

    596 Pages

  9. Model No. PB

    104 Pages

  10. SANMOTION_C

    12 Pages

  11. DC SERVO SYSTEMS

    36 Pages

Archived catalogs