Parallel redundant UPS with lithium-ion battery UPS unit T Terminal block, ● P Plug, ● C Outlet Input and output connector types are indicated by the following icons: ● [No. of phases/wires] Input voltage [No. of phases/wires] Output voltage Scalability Input Output Free(Max. 20 kVA)(1) connector connector standing Specifications Dimensions Rack mount (1) Up to four 5 kVA UPS units can be combined. The expansion can be done even after installation. (2) At a 25ºC ambient temperature and load power factor of 0.9, using new, fully charged batteries. (3) These are a set of a UPS unit(s) + battery(ies)...
Open the catalog to page 2SANUPS A11N-Li Installation examples Mountable in an EIA standard 19-inch rack Rack support rails are optional. You can change the orientation of the LCD panel. Floor mounting brackets are included as standard for the single unit type (shown in the photo) and optional for types with a PDU. Long Service Life ● Easy Maintenance The UPS uses lithium-ion batteries. Models with built-in maintenance bypass circuit can It can operate for 10 years without battery replace- continue to supply grid power during maintenance. UPS ment,(1) reducing the maintenance work and costs. units can be replaced without...
Open the catalog to page 3Power distribution unit Parallel operation (N configuration) Parallel redundant operation (N+1 configuration) Load Level vs Backup Time Load level [%] Battery backup time [min] Note: At 25ºC ambient temperature and load power factor of 0.9, using new, fully charged batteries. Views and Part Names Front Operating Panel Input Power LED Backup LED Warning LED Inverter ON/STANDBY Button Inverter ON/ Output LED STANDBY Button Menu Operation Buttons Main Breaker Remote/EPO Terminal PC Port (USB Type C) Optional Card Interface Alarm LED Output LED Input Power LED Optional Card Slot Dry Contact Signal...
Open the catalog to page 4SANUPS A11N-Li Specifications Output capacity Order no. Rated output capacity (apparent power / active power) Technology Single-unit/Parallel operation (N config.) Parallel redundant operation (N+1 config.) ― Topology Double conversion online Cooling system Rated voltage 200/208/220/230/240 V (Same as output voltage) Within -40% to +15% of rated voltage 50/60 Hz (Auto-sensing or fixed-frequency mode selectable.(2) Factory setting: auto-sensing) Rated frequency Required capacity Input power factor 0.95 or greater (at rated input voltage, input voltage harmonic distortion < 1%) Rated voltage 200/208/220/230/240...
Open the catalog to page 5Specifications Output capacity Order no. Rated output capacity (apparent power / active power) Technology Single-unit/Parallel operation (N config.) Parallel redundant operation (N+1 config.) 5 kVA / 4.5 kW Topology Double conversion online Cooling system Rated voltage 200/208/220/230/240 V (Same as output voltage) Within -40% to +15% of rated voltage 50/60 Hz (Auto-sensing or fixed-frequency mode selectable.(2) Factory setting: auto-sensing) Rated frequency Required capacity Input power factor 0.95 or greater (at rated input voltage, input voltage harmonic distortion < 1%) Rated voltage 200/208/220/230/240...
Open the catalog to page 6Output capacity Order no. Rated output capacity (apparent power / active power) Technology Single-unit/Parallel operation (N config.) Parallel redundant operation (N+1 config.) 10 kVA / 9 kW Topology Double conversion online Cooling system Rated voltage 200/208/220/230/240 V (Same as output voltage) Within -40% to +15% of rated voltage 50/60 Hz (Auto-sensing or fixed-frequency mode selectable.(2) Factory setting: auto-sensing) Rated frequency Required capacity Input power factor 0.95 or greater (at rated input voltage, input voltage harmonic distortion < 1%) Rated voltage 200/208/220/230/240 V (Selectable....
Open the catalog to page 7Specifications Output capacity Order no. Rated output capacity (apparent power / active power) Technology Single-unit/Parallel operation (N config.) Parallel redundant operation (N+1 config.) 15 kVA / 13.5 kW Topology Double conversion online Cooling system Rated voltage 200/208/220/230/240 V (Same as output voltage) Within -40% to +15% of rated voltage 50/60 Hz (Auto-sensing or fixed-frequency mode selectable.(2) Factory setting: auto-sensing) Rated frequency Required capacity Input power factor 0.95 or greater (at rated input voltage, input voltage harmonic distortion < 1%) Rated voltage 200/208/220/230/240...
Open the catalog to page 8SANUPS A11N-Li Dimensions (Unit: mm) Model: S-A11NL502A010N Output Outlet Breaker Ground Terminal External Battery Connector Maintenance Bypass Breaker Communication Interface (See Views and Part Names) Model: S-A11NL502A010T Breaker for NEMA L6-30R Floor mounting brackets (Supplied) Ground Terminal External Battery Connector Maintenance Bypass Breaker Communication Interface (See Views and Part Names) Output Outlet Breaker (25) Unit-to-Unit Connector Ground Terminal External Battery Connector Maintenance Bypass Breaker Communication Interface (See Views and Part Names) 30 Unit-to-Unit Communication...
Open the catalog to page 9Dimensions (Unit: mm) Model: S-A11NL502A010S2 (1) UPS Unit - Rear View (25) External Battery Connector Unit-to-Unit Connector Unit-to-Unit Communication Port (2) PDU - Front Interior View Input Breaker (2) Output Outlet Breaker Maintenance Bypass Breaker Communication Interface (See Views and Part Names) Unit-to-Unit Connector Paint color: Black (Munsell N1.5)
Open the catalog to page 10(1) UPS Unit - Rear View External Battery Connector Unit-to-Unit Connector Unit-to-Unit Communication Port (2) PDU - Front Interior View Input Breaker Output Breaker Communication Interface (See Views and Part Names) Maintenance Bypass Breaker (2) Mass: 339 kg Unit-to-Unit Communication Port Paint color: Black (Munsell N1.5)
Open the catalog to page 11Dimensions (Unit: of Options mm) (Unit: mm) ■ Rack support rails Used for mounting the UPS in an EIA standard 19-inch rack. (A pair of left and right rails. Shown below is the left rail.) Front bracket Rear bracket Rack mounting dimensions Mass: Approx. 2.6 kg (5.2 kg for a pair of left and right rails) Rack mounting brackets for securing a UPS in a rack come included with or installed to the UPS. Network Options Item When installed in the optional card slot, this card enables 24/7 monitoring of UPS operations and status, and sends email notifications to system administrators for quick actions...
Open the catalog to page 1216 Pages
104 Pages
196 Pages
52 Pages
4 Pages
4 Pages
4 Pages
5 Pages
5 Pages
5 Pages
2 Pages
172 Pages
36 Pages
128 Pages
84 Pages
12 Pages
247 Pages
4 Pages
2 Pages
4 Pages
2 Pages
2 Pages
20 Pages
4 Pages
2 Pages
5 Pages
56 Pages
40 Pages
36 Pages
40 Pages
64 Pages
378 Pages
673 Pages
670 Pages
11 Pages
91 Pages
126 Pages
4 Pages
3 Pages
6 Pages
12 Pages
126 Pages
4 Pages
8 Pages
332 Pages
56 Pages
8 Pages