SANYO DENKI San Ace 92DC Fan ■ Features Low Noise Compared to our current product,111 noise level has been reduced by 5 dB(A). Energy Saving Power consumption has been reduced by approximately 13% compared to the current product.(2) High Static Pressure The maximum static pressure has increased by approximately 8% compared to the current product.(1) Rich Lineup The lineup offers four different rotational speeds for each of 12/24/48 V rated voltages. The broad lineup of fans enables you to choose the right fan best suited to your applications. (1) Comparison of the new product (model 9RA0948J1001) and current DC fan of the same size (model 9G0948J101). (2) Comparison of the new product (model 9RA0912G1001) and current DC fan of the same size (model 9G0912G101). The models listed below have ribs and pulse sensors with PWM control function. For models without ribs, append "1" to the end of model numbers. Models with the following sensor specifications are also available as options: Lock sensor
Open the catalog to page 1■ Airflow - Static Pressure Characteristics PWM duty cycle Operating voltage range PWM duty cycle 100% Operating voltage range (inch H2O) (Pa) 0.8 200 _ 180 160
Open the catalog to page 292 × 92 × 38 mm ■ Airflow - Static Pressure Characteristics Operating voltage range Static pressure Static pressure Static pressure Static pressure Static pressure ■ PWM Duty - Speed Characteristics Example (min-1) 7000
Open the catalog to page 3■ PWM Input Signal Example Input signal waveform VIH = 4.75 to 5.25 V VIL = 0 to 0.4 V T1 1 PWM frequency 25 (kHz) = ×100 T T Current source (Isource) = 1.0 mA max. (when control voltage is 0 V) PWM duty cycle (%) = Current sink (Isink) = 1.0 mA max. (when control voltage is 5.25 V) VIL When the PWM control terminal is open, the fan speed is the same as the speed at 100% PWM duty cycle. The PWM signal can be used with open collector or drain input. Note that when using an open collector or drain input, T or inputting a different voltage or frequency, the speed relative to the PWM duty cycle may...
Open the catalog to page 416 Pages
16 Pages
104 Pages
196 Pages
52 Pages
4 Pages
4 Pages
5 Pages
5 Pages
5 Pages
2 Pages
172 Pages
36 Pages
128 Pages
84 Pages
12 Pages
247 Pages
4 Pages
2 Pages
4 Pages
2 Pages
2 Pages
20 Pages
4 Pages
2 Pages
5 Pages
56 Pages
40 Pages
36 Pages
40 Pages
64 Pages
378 Pages
673 Pages
670 Pages
11 Pages
91 Pages
126 Pages
4 Pages
3 Pages
6 Pages
12 Pages
126 Pages
4 Pages
8 Pages
332 Pages
56 Pages
8 Pages