San Ace 40 - 1

40×40×28 mm San Ace 40 9GV type ■ General Specifications ・ Material ………………………………………… Frame: Plastic (Flammability: UL 94V-0), Impeller: Plastic (Flammability: UL 94V-0) ・ Expected life …………………………………… See the table below. (L10 life: 90% survival rate for continuous operation in free air at 60˚C, rated voltage) ・ Motor protection function ………………… Locked rotor burnout protection, Reverse polarity protection For details, please refer to p. 529. ・ Dielectric strength …………………………… 50/60 Hz, 500 VAC, for 1 minute (between lead wire conductors and frame) ・ Insulation resistance………………………… 10 MΩ or more with a 500 VDC megger (between lead wire conductors and frame) ・ Sound pressure level (SPL) ……………… At 1 m away from the air inlet ・ Storage temperature ……………………… -20 to +70˚C (Non-condensing) ・ Lead wire ……………………………………… ■ Specifications The models listed below have ribs and pulse sensors. For models without ribs, append "1" to the end of model numbers. Rated voltage Operating voltage range Rated current Rated input Rated speed Operating temperature Expected life Other sensor specifications are available as options. Refer to the index (p. 554). ■ Airflow - Static Pressure Characteristics 9GV0412K301 With pulse sensor Operating voltage range With pulse sensor Operating voltage range Operating voltage range Static静圧 pressure Static静圧 pressure With pulse sensor

Open the catalog to page 1
San Ace 40 - 2

■ Airflow - Static Pressure Characteristics 9GV0412H301 With pulse sensor Operating voltage range Operating voltage range Static静圧 pressure Static静圧 pressure (With ribs) 4-ø3.5±0.3 Mounting hole 取付用穴 Lead wire リー ド線 AWG26 UL 1007 +30 320 0 With pulse sensor Airflow direction 風吹出方向 Rotating direction 回転方向 ■ Reference Dimensions of Mounting Holes and Vent Opening (unit: mm) Inlet side, Outlet side 39

Open the catalog to page 2

All SANYO DENKI America catalogs and technical brochures

  1. SANUPS A11N-Li

    16 Pages

  2. SANMOTION G

    104 Pages

  3. SANMOTION R

    196 Pages

  4. San Ace 40L

    4 Pages

  5. SANMOTION R 3E

    172 Pages

  6. SANMOTION T

    36 Pages

  7. SANMOTION F5

    128 Pages

  8. SANMOTION F2

    84 Pages

  9. SANMOTION C

    12 Pages

  10. DC Fan Catalog

    247 Pages

  11. San Ace 92W

    4 Pages

  12. San Ace B97

    2 Pages

  13. San Ace 60T

    2 Pages

  14. Blower

    20 Pages

  15. ACDC Fan

    5 Pages

  16. SANMOTION R

    40 Pages

  17. Hybrid UPS

    8 Pages

Archived catalogs

  1. AC_San_Ace

    56 Pages

  2. DC_San_Ace

    332 Pages

  3. PD-D11A

    8 Pages