YX-361TR
1 / 1Pages

Catalog excerpts

YX-361TR - 1

SANWA ANALOG MULTITESTER YX360 TRF/ YX-361TR General Specifications YX360TRF Meter structure Standard calibration temperature / humidity Operating temperature / humidity Storage temperature / humidity Battery (built-in) fuse (built-in) Withstand voltage 6kV AC (1 min.) between input terminal and case Environmental condition Altitude 2,000m or below, pollution degree II Dimensions / weight Test lead (TL-61T), Hand strap, Instruction manual Test lead (TL-61), Instruction manual HV probe (HV-10T), Clip adapter (CL-11, TL-8IC), hFE probe (HFE-6T) HV probe (HV-10), Clip adapter (CL-11, TL-8IC), hFE probe (HFE-6), Carrying case (C-YS) Accessories Optional accessories Measuring range Input impedance 9k /V 30Hz ~ 100kHz within ±3% f.s. (AC10V) Center value 20 , Max. Value 2k Release voltage 3V 1 range / 0 ~ 15mA at 10 range / 0 ~ 1.5mA at 100 range / 0 ~ 150uA at 1k range / 0 ~ 1.5uA at 100k range 1000 at Optional probe HV-10T is necessary Optional probe HFE-6T is necessary *1: Not including the resistance of fuse. / *2: Pointer indication of the maximum move by charged current in the capacitor. Specification: YX-361TR Measuring range ±3% of full scale ±4% of full scale (10V or below) Terminal voltage drop 250mV Function DCV DCV (NULL) ACV DCmA 0 ~ 0.2 ~ 2k at 1 range, center 20 0 ~ 2 ~ 20k at 10 range, center 200 0 ~ 20 ~ 200k at 100 range, center 2k 0 ~ 200 ~ 2M at 1k range, center 20k 0 ~ 2k ~ 20M at 10k range, center 200k LED for continuity check at 1range (Emitting light at 10 dB LI LV Battery check HV (DC high voltage) Current across test pins 1k range / 0 ~ 1.5mA at 100 range / 10 range / 0 ~ 150mA at 1 range range 3V ~ 0V (Reverse of LI scale) 0 ~ 1.5V ±4% of full scale (10V or below) ±5% of arc ±5% of arc ±5% of full scale Dempa Bldg, 4-4 Sotokanda 2-Chome Chiyoda -ku, Tokyo 101-0021, Japan Tel: + 81- 3 -3251- 0941 Fax : + 81- 3 - 3256 - 9740 Input impedance 9k / V 30Hz ~ 100kHz ±1dB 10V or below 40Hz ~ 30kHz ±3% Current across terminals while object is measured. Voltage applied across terminals while Load current 0.25A Optional probe HV-10 is necessary

Open the catalog to page 1

All Sanwa Electric Instrument catalogs and technical brochures

  1. CD5001

    2 Pages

  2. LP10

    1 Pages

  3. KD3

    1 Pages

  4. LX20

    1 Pages

  5. TH20

    1 Pages

  6. TH1

    1 Pages

  7. TH3

    1 Pages

  8. DM508S

    1 Pages

  9. PDM5219S

    1 Pages

  10. HG561H

    4 Pages

  11. DLC460F

    1 Pages

  12. DCM600DR

    2 Pages

  13. DCL31DR

    1 Pages

  14. DCM660R

    2 Pages

  15. DCM60R

    1 Pages

  16. DCL1200R

    2 Pages

  17. DCM-22AD

    1 Pages

  18. DCL1000

    2 Pages

  19. EM7000

    1 Pages

  20. CD800a

    1 Pages

  21. RD700

    1 Pages

  22. PC20

    1 Pages

  23. PC720M

    2 Pages

  24. PC700

    2 Pages

  25. CAM600S

    2 Pages

  26. AP33

    1 Pages

  27. PM11

    1 Pages

  28. CD732

    1 Pages

  29. KIT-8D

    2 Pages

  30. PC510a

    1 Pages

  31. PC500a

    1 Pages

  32. PC5000 a

    1 Pages

Archived catalogs