General Catalog

General Catalog
1 / 27 PagesView full catalog

General Catalog

Product catalog summary
Overview: The document is a comprehensive guide on measuring instruments, focusing on digital multimeters (DMMs) and their functionalities, emphasizing accurate measurements and Sanwa's role in providing high-quality solutions globally.
Main Sections:
  • True RMS Measurement: Essential for accurate AC current and voltage measurements of non-sine waves.
  • Functionality and Features: Includes dual display, drop shock proof design, leakage current measurement, and duty cycle analysis.
  • Measurement Capabilities: Covers DC/AC current, frequency, capacitance, continuity, battery voltage, with features like peak hold and automatic measurement selection.
  • Data Handling: Highlights data hold, range hold, logging, and USB connection for efficient data management.
  • Additional Functions: Auto power off, auto power save, and backlight for usability in various conditions.
  • Technical Specifications: Details on input resistance, resolution, clamp diameter, and display digit.
  • Glossary and Model Listings: Includes a glossary of terms and a list of models with applications.
  • Sanwa's Mission: Aims to contribute to global environmental conservation and energy management.
Key Takeaways:
  • Digital multimeters offer high accuracy and reduced measuring loss.
  • True RMS measurement is crucial for non-sine waveforms.
  • Data management features enhance usability and efficiency.
  • Sanwa is committed to providing reliable measuring solutions worldwide.
Operating Environment: PC Link system compatible with Windows XP, 7, 8, and 10, requiring a Pentium IV 1.6GHz CPU, 1GB memory, and 800x600 resolution.
PC Link System: Software for retrieving data from SANWA digital multimeters, displaying real-time graphs, and saving data in CSV format.
Digital Multimeter Features: Comparative chart of models highlighting features like True RMS, dual display, and data logging capabilities.
Optional Accessories: Includes software, optical PC link cables, clamp probes, temperature probes, and carrying cases.
Safety and Standards: Compliance with IEC61010-1 and IEC61010-31, ensuring safe operation up to CAT.III 600V and CAT.II 1000V, and EN61326-1 for electromagnetic compatibility.
Specifications: Detailed specifications for models like PM3, PM11, PM33a, and KP1, outlining measurement capabilities and accuracy.
Safety Standards: Compliance with IEC61010-1 and other relevant standards, with varying categories depending on the model.
Additional Features: Auto range, analog bar graphs, data hold, and continuity check with a buzzer.
Recommendations: Advises checking the range before measurement and suggests specific models for particular applications.
Analog Multitesters: Used for measuring DC voltage, AC voltage, DC current, and resistance.
Insulation Resistance Testers: Importance of insulation resistance testing for safety control in electric equipment.
Choosing a Suitable Model: Advice on selecting between analog and digital types based on measurement needs.
Comparative Charts: Provided for insulation resistance testers, detailing model specifications and features.
Conclusion: A comprehensive guide for selecting and understanding measuring instruments, emphasizing safety and accuracy.
Company Overview and Certifications: Electric Instrument Co., Ltd. achieved ISO9001:2000 and ISO 14001 certifications, emphasizing environmental management.
Environmental Philosophy: Focus on environmentally balanced activities involving all employees.
Traceability and Calibration: Sanwa products are calibrated using reference samples compliant with national standards.
Safety Standards and Usage Guidelines: Emphasizes the importance of using instruments within specified categories for safety.
Measurement Categories: Defined by IEC standard, advising on protective measures and appropriate equipment usage.
CE Marking and Directives: Compliance with EC Directive safety requirements, ensuring protection against electric shocks and electromagnetic interference.
Impulse Withstand Voltage: Specifications for impulse withstand voltage across different measurement categories.
See more

Catalog excerpts

General Catalog-2

Function marks and terminology used in Sanwa sees its mission as contributing to global environmental conservation and energy management through continuous advances in electrical and on-site measuring instruments, while “putting the trust and satisfaction of customers first”. Digital Multimeter Insulation Resistance Tester Top class quality popular in 74 countries around the world. This quality control includes not only “products”, but also each and every operation, maintenance services, and sales and marketing activities, and is thoroughly implemented utilizing reliable systems and the intangible...

 Open the catalog to page 2
General Catalog-3

Control panel Insulation resistance tester MODEL: MG1000 P22-27 Multimeter / DC clamp meter MODEL: DCM2000DR P28-35 Clamp meter MODEL: DCM2000DR P28-35 Multimeter MODEL: CD772 P7-16 Speedometer MODEL: SE9100 P38 Solar panel Insulation resistance tester MODEL: M53 P26 Power conditioner Illuminance meter MODEL: LX20 P36 Clamp meter MODEL: DCM660R P28-35 Insulation resistance tester MODEL: MG1000 P22-27 Insulation resistance tester MODEL: PDM5219S P22-27 Distribution board Clamp meter MODEL: DCM60R P28-35 Insulation resistance tester MODEL: MG1000 P22-27 Industrial Machine Distribution board Tachometer...

 Open the catalog to page 3
General Catalog-4

Digital Multimeters Enhanced operational efficiency by means of data retrieval software, PC Link 7, which can handle measurements for up to a maximum of 8 channels. The PC Link system is the software dedicated to a PC for retrieving data outputted from a SANWA digital multimeter (PC series). The operation screen displays graphs in real time to allow you to check changes in measured values (voltage, current, etc.) with ease. Measured data can be saved on a CSV file, so it is easily processed on Excel. The ease of use in a variety of applications from data retrieval, processing and analysis results...

 Open the catalog to page 4
General Catalog-5

Digital Multimeter Comparative Chart MΩ test voltage Capacitance (F) max Diode test Diode test Ducy cycle Ducy cycle Data hold Data hold Range hold Range hold Peak hold Relative value Auto power off/save Battery check Data logging Auto power off/save Battery check Data logging ▲ Optional accessories are necessary. Peak hold Relative value Various Instruments Clamp Meter Various Instruments

 Open the catalog to page 5
General Catalog-6

PC Link System, Digital Multimeter PC Link System, Digital Multimeter 500000 Count for DCV, Dual Display Dual Display, Best Accuracy 0.06% Display : numeral display 50000 & 500000 selectable,      bar graph 41 segments Sampling rate : 5 times/sec. for 50000 count, 1.25           times/sec. for 500000 count, 60            times/sec. for bar graph Safety : IEC61010-1, IEC61010-31 CAT.III 600V Max./CAT. II 1000V Max., EN61326-1 Battery life : Approx. 100h (alkaline battery) at DCV range Measuring range Best accuracy Resolution Input impedance Logic frequency Duty cycle Buzzer sounds at between 20Ω...

 Open the catalog to page 6
General Catalog-7

CD772 Backlight & Temperature measurement 11000 Count Minimum resolution 0.01mV, 0.01Ω Display : numeral display 11000 Sampling rate : 4 times / sec. AC frequency bandwidth : 45∼100Hz(110mV range), 45∼500Hz(1.1V range), 45∼1kHz(11V range and avobe, ACA) Safety : IEC61010-1 (EN61010-1) CAT.III 600V Max. / CAT.II1000V Max. Measuring range Best accuracy Resolution Input impedance Buzzer sounds and LED lights up at less than 30Ω Open Voltage: approx. 0.2V Diode test Open Voltage: approx. 0.2V ■3-3/4 digits 4000 count ■AC True RMS ■Easy to read large LCD with Backlight ■Large breaking capacity fuse...

 Open the catalog to page 7
General Catalog-8

Display : numeral display 6000, bar graph 61 segments Sampling rate: 3 times/sec., 30 times/sec., for bar graph Safety : EN61010-1, EN61010-2-030, EN61010-2-033 CAT.III 600V / CATII DC1000V・AC750V IEC61010-031 Best accuracy Resolution Input impedance Duty cycle Buzzer sounds and LED lights up at between 10∼60Ω Open voltage : approx. 0.63V Diode test Open voltage : approx. 2.7V Size / Mass Standard accessories included Test lead(TL-25a), Holster(H-70), Instruction manual Measuring range Best accuracy Resolution Duty Cycle Buzzer sounds at less than 10∼120Ω. Open voltage : approx. 0.4V Diode Test...

 Open the catalog to page 8
General Catalog-9

■AC True RMS ■Self test - checking failures of LCD, disconnection of a lead wire ■EF (Electric Field) detection ■LCD with backlight & LED light for dark place ■Auto data hold ■Auto power off (1min.) Best accuracy Buzzer sounds at between 20kΩ and 500kΩ Open voltage: approx. 0.6V A voltage or electric field of about 60V or more is detected. The bar graph and intermittent buzzer beeps change in five steps Size / Mass Standard accessories included H130XW90XD30mm/approx. 205g Test leads (TL-35 : Test probe (red), TL-36 : Test lead (black), TL-A01 : Test probe (black), Instruction manual Optional...

 Open the catalog to page 9
General Catalog-10

Drop Shock Proof Meter EM7000 High sensitivity for measurement of lower capacitance Sine wave:8.4V (approx. 2.5MΩ/V)/ 33V (approx. 1.1MΩ/V) ±5% of full scale 84V (approx. 800MΩ/V)/330/840V (approx. 800kΩ/V) Square symmetric wave:8.4V (2.5MΩ/V) Triangular symmetric wave:8.4V (2.5MΩ/V) ±3% of scale length ±3% of scale length Optional accessories Measuring range Size / Mass CX506a Capacitor & Transistor checker (built-inoscillator) ■ 26ch switch, wide range measurement ■ Capacitance measurement 50pF∼2000μF ■ High input impedance 50kΩ / V (DC3∼300Vrange) ■ Switchable DC polarity Bandwidth : 40Hz∼30kHz...

 Open the catalog to page 10
General Catalog-11

Drop shock proof meter YX360TRF Best seller drop shock proof meter Measuring range ■ Drop shock proof meter ■ Null (zero center) meter ±5 / ±25 in DCV ■ High resistance up to 200MΩ with low voltage ■ Protective body cover ■ Capacitance, dB, Li measurement DC25kV (optional probe "HV-10T" is necessary) 1000 at ×10 range (optional probe "HFE-6T" is necessary) ■ Low power ohm (3V) measurement up to 200MΩ ■ Capacitance measurement 0.01μF∼1000μF ■ LED check by 3V terminal voltage at resistance range ■ Battery check ■ Protective body cover Standard accessories included Protective body cover Measuring...

 Open the catalog to page 11

All Sanwa Electric Instrument catalogs and technical brochures

  1. CD5001

    2  Pages

  2. LP10

    1  Page

  3. KD3

    1  Page

  4. LX20

    1  Page

  5. TH20

    1  Page

  6. TH1

    1  Page

  7. TH3

    1  Page

  8. DM508S

    1  Page

  9. PDM5219S

    1  Page

  10. HG561H

    4  Pages

  11. DLC460F

    1  Page

  12. DCM600DR

    2  Pages

  13. DCL31DR

    1  Page

  14. DCM660R

    2  Pages

  15. DCM60R

    1  Page

  16. DCL1200R

    2  Pages

  17. DCM-22AD

    1  Page

  18. DCL1000

    2  Pages

  19. EM7000

    1  Page

  20. CD800a

    1  Page

  21. RD700

    1  Page

  22. PC20

    1  Page

  23. PC720M

    2  Pages

  24. PC700

    2  Pages

  25. CAM600S

    2  Pages

  26. YX-361TR

    1  Page

  27. AP33

    1  Page

  28. PM11

    1  Page

  29. CD732

    1  Page

  30. KIT-8D

    2  Pages

  31. PC510a

    1  Page

  32. PC500a

    1  Page

  33. PC5000 a

    1  Page

Archived catalogs

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.