CD5001

CD5001

CD5001

Product catalog summary
Overview: The CD5001 is a digital multimeter designed for true RMS measurements, suitable for low-voltage circuit measurements in electrical work sites. It features a compact, lightweight design with a large, easy-to-read display and several automatic functions for ease of use.
Key Features:
  • Full 4-digit 9999 count display
  • True RMS measurement capability
  • EF (Electric Field) sensing for detecting AC voltage
  • AUTO V function for automatic AC/DC voltage distinction
  • Auto Hold function to stabilize and hold measurement values
  • Auto power off after 30 minutes of inactivity (cancelable)
  • Bright backlight for visibility
Specifications:
  • Measuring Range: DCV and ACV up to 999.9V, Resistance up to 99.99MΩ, Capacitance up to 99.99mF, Frequency up to 99.99kHz
  • Accuracy: DCV ±(0.5%+2), ACV ±(1.0%+5), Resistance ±(0.5%+5), Capacitance ±(5%+5), Frequency ±(0.1%+5)
  • Resolution: 0.1mV for voltage, 0.1Ω for resistance, 0.1nF for capacitance, 0.001Hz for frequency
  • Input Impedance: 10MΩ to 11MΩ
  • Display: Max. 9999 counts with a sampling rate of approx. 5 times/sec
  • Operating Conditions: Temperature 5 to 40℃, Humidity 80% RH max (without condensation)
  • Power: LR03 X 2 batteries, approx. 550 hours battery life
  • Safety Standards: IEC61010 CAT. IV 600V / CAT. III 1000V
Additional Features:
  • Test lead holders for one-hand operation
  • Optional hanger magnet for hands-free use
  • Tilt stand for angled positioning
See more

Catalog excerpts

CD5001-1

DIGITAL MULTIMETER This instrument is a true RMS (root mean square) digital multimeter designed for measurements within the range of CAT. IV 600V and CAT. III 1000V. It is suitable for measurements in electrical work sites of low-voltage circuits. ●Full 4-digit 9999 count ●True RMS ●EF (Electric Field) sensing ●AUTO V function automatically distinguishes between DC and AC voltage. ●Auto Hold function automatically holds the measurement value once it stabilizes. ●Large, easy-to-see display ●Compact, lightweight, easy-to-hold design ●Auto power off after approx. 30min of inactivity(cancelable) ●Bright backlight SPECIFICATIONS DCV ACV Resistance Capacitance Frequency Continuity EF detection Best accuracy Resolution Measuring range 0.1mV ±(0.5%+2) 999.9m/9.999/99.99/999.9V 0.1mV ±(1.0%+5) 999.9m/9.999/99.99/999.9V 0.1Ω ±(0.5%+5) 999.9/9.999k/99.99k/999.9k/9.999M/99.99MΩ 0.1nF ±(5%+5) 999.9n/9.999µ/99.99µ/999.9µ/9.999m/99.99mF 0.001Hz ±(0.1%+5) 9.999/99.99/999.9/9.999k/99.99kHz Buzzer sounds at 30 to 70Ω or less Open voltage: approx. 0.6V Detects ACV and EF of approx. 80V or more Operation method AC detection method Display Sampling rate Over-range display Range selection Polarity switching Battery low warning Δ-Σ method True RMS (AC coupling) Max. 9999 counts Approx.5 times/sec. (DCV) "OL" shown in numeric section Auto and manual Automatic selection (Only "-" is displayed.) lights up on display when supply voltage from internal batteries drops below about 2.5V. Operating environmental condition Altitude no more than 2000 m, indoor use, environmental pollution degree II Operating temperature / humidity Temperature: 5 to 40℃ Humidity is as follows (without condensation) . 5 to 31℃: Max.80%RH 31 to 40℃: Linearly decreases from 80% RH to 50% RH. Storage temperature / humidity Temperature -10 to +40℃:No more than 80% RH, without condensation Temperature +40 to +50℃: No more than 70% RH, without condensation Power consumption Approx.2 mA (during DCV measurement, with backlight off) Battery life Approx.550 hours (during DCV measurement, with backlight off) Safety standards IEC61010 CAT. IV 600V / CAT. III 1000V EMC Directive IEC61326 Bandwidth 40 - 400 Hz Battery LR03 X 2 Size / Mass H149 X W72 X D37 mm / approx. 232 g Standard accessories included Test lead (ATL101), Instruction manual Dempa Bldg, 4-4 Sotokanda 2-Chome, Chiyoda-Ku, Tokyo 101-0021 Japan Tel:+81-3-3251-0941 Fax:+81-3-3256-9740 A battery for monitoring has been installed prior to shipment from the factory. It may be discharged before the expiration of the described battery life. This battery is used to check the functions and performance of the product.Specifications and external appearance of the product described above may be r

 Open the catalog to page 1
CD5001-2

DIGITAL MULTIMETER This function detects the electric field generated by AC voltage. Compact design Test lead holders These are useful for test leads storing, and also enable users to take measurements with one hand. AUTO HOLD function When a new stable measurement value is detected in the Auto Hold mode, the buzzer sounds, and the new measurement value is automatically held. Tilt stand This enables the device to stand at an angle on a table etc. and users to take measurements with both hands. This function automatically detects whether the input voltage is AC or DC. Hanger magnet HM-1 (optional...

 Open the catalog to page 2

All Sanwa Electric Instrument catalogs and technical brochures

  1. General Catalog

    27  Pages

  2. LP10

    1  Page

  3. KD3

    1  Page

  4. LX20

    1  Page

  5. TH20

    1  Page

  6. TH1

    1  Page

  7. TH3

    1  Page

  8. DM508S

    1  Page

  9. PDM5219S

    1  Page

  10. HG561H

    4  Pages

  11. DLC460F

    1  Page

  12. DCM600DR

    2  Pages

  13. DCL31DR

    1  Page

  14. DCM660R

    2  Pages

  15. DCM60R

    1  Page

  16. DCL1200R

    2  Pages

  17. DCM-22AD

    1  Page

  18. DCL1000

    2  Pages

  19. EM7000

    1  Page

  20. CD800a

    1  Page

  21. RD700

    1  Page

  22. PC20

    1  Page

  23. PC720M

    2  Pages

  24. PC700

    2  Pages

  25. CAM600S

    2  Pages

  26. YX-361TR

    1  Page

  27. AP33

    1  Page

  28. PM11

    1  Page

  29. CD732

    1  Page

  30. KIT-8D

    2  Pages

  31. PC510a

    1  Page

  32. PC500a

    1  Page

  33. PC5000 a

    1  Page

Archived catalogs

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.