UCMSC - 1

Aerial Cam Unit General Description of UCMSF FOR PIERCE equal to the cam width and reduction of weight. Y V-shaped guide. Y Available angle is 0˚ to 70˚ at increments of 5˚. qOption of UCMSF UKey specification(-K) U Features of UCMSF Y Space saving design with the mounting width UHome Position kit (-S) UCMSF 150 90±0.05 The jig (q Collar w Bolt e Nut) for locking the bottom dead center is accompanied as shown in the figure below. The stopper plate has tapped 32 3 threads for installation. Spring guide pin Copper alloy bushing Stopper plate Copyright © Sankyo Oilless Industry, Inc. All Rights Reserved. qStructure of UCMSF UCMSF is the 2-stage spring type is used to improve the spring force. Copper alloy for high pressure is used for the cam slide guide (cam bottom) to increase the force. UCMSF 150 T-shaped key grooves are additionally machined as shown in the figure below.

Open the catalog to page 1
UCMSC - 2

Aerial Cam Unit General Description of UCMSF FOR PIERCE qUCMSF80 Structure and Assembly / Disassembly qUCMSF150 Structure and Assembly / Disassembly 1) Remove hexagon socket head bolt ( ) and remove safety plate (!1). 2) Remove hexagon socket head bolt ( ) and remove stopper plate (o). 3) Pull and remove cam slider (w) from cam holder (q)to the rear. tAssembly method of UCMSF80 1) Assemble components in the reverse order of disassembly. Y Make sure that there is no foreign matter on the sliding area and assemble components. YThe clearance between the guide bar/cam slider and the cam holder...

Open the catalog to page 2
UCMSC - 3

Aerial Cam Unit( FOR PIERCE H 0 When ordering WC, set the position of the piercing center within the cam width. UCMSF80 - 00 - K UCMSF80 - 00 - SC60 der UCMSF80 - 00 - WC120 UCMSF80 - 00 - SC30 - WC100 - N16 - K For machining details or tapping hole and dowel hole (prepared hole and finished hole) for mounting of the retainer, refer to page 561. For detailed specification of the key, refer to page 880. SSSAttaching the SC and WC options raises the mounting surface height 20 mm. If only a mounting surface height of 20 mm is required, specify "SC 0". ■Space for removing ■Spring Diagram...

Open the catalog to page 3
UCMSC - 4

Aerial Cam Unit( FOR PIERCE Option Code 0 When ordering WC, set the position of the piercing center within the cam width. SSSAttaching the SC and WC options raises the mounting surface height 20 mm. If only a mounting surface height of 20 mm is required, specify "SC 0". ■Space for removing UCMSF80 - 05 - K UCMSF80 - 05 - SC60 erUCMSF80 - 05 - WC120 UCMSF80 - 05 - SC30 - WC100 - N16 - K For machining details or tapping hole and dowel hole (prepared hole and finished hole) for mounting of the retainer, refer to page 561. For detailed specification of the key, refer to page 880. 0 Bolts for...

Open the catalog to page 4
UCMSC - 5

Aerial Cam Unit( FOR PIERCE Option Code 0 When ordering WC, set the position of the piercing center within the cam width. SSSAttaching the SC and WC options raises the mounting surface height 20 mm. If only a mounting surface height of 20 mm is required, specify "SC 0". ■Space for removing UCMSF80 - 10 - K UCMSF80 - 10 - SC60 erUCMSF80 - 10 - WC120 UCMSF80 - 10 - SC30 - WC100 - N16 - K For machining details or tapping hole and dowel hole (prepared hole and finished hole) for mounting of the retainer, refer to page 561. For detailed specification of the key, refer to page 880. 0 Bolts for...

Open the catalog to page 5
UCMSC - 6

Aerial Cam Unit( FOR PIERCE Catalog No. (W) (9)UCMSF 80-15 HOption of SC or WC Option Code 0 When ordering WC, set the position of the piercing center within the cam width. SSSAttaching the SC and WC options raises the mounting surface height 20 mm. If only a mounting surface height of 20 mm is required, specify "SC 0". ■Space for removing UCMSF80 - 15 - K UCMSF80 - 15 - SC60 erUCMSF80 - 15 - WC120 UCMSF80 - 15 - SC30 - WC100 - N16 - K For machining details or tapping hole and dowel hole (prepared hole and finished hole) for mounting of the retainer, refer to page 561. For detailed...

Open the catalog to page 6
UCMSC - 7

Aerial Cam Unit( FOR PIERCE Option Code ■Option of SC or WC 0 When ordering WC, set the position of the piercing center within the cam width. UCMSF80 - 20 - K UCMSF80 - 20 - SC60 erUCMSF80 - 20 - WC120 UCMSF80 - 20 - SC30 - WC100 - N16 - K For machining details or tapping hole and dowel hole (prepared hole and finished hole) for mounting of the retainer, refer to page 561. For detailed specification of the key, refer to page 880. 0 Bolts for assembly are not indicated. ■Space for removing ■Spring Diagram •Spring Used For Initial Load : TF25-100(1 Piece) 9.80N/mm(1.00kgf/mm) For Final...

Open the catalog to page 7
UCMSC - 8

Aerial Cam Unit( FOR PIERCE Catalog No. (W) UCMSF 80 (K)25 ■Option of SC or WC Option Code 0 When ordering WC, set the position of the piercing center within the cam width. ^Attaching the SC and WC options raises the mounting surface height 20 mm. If only a mounting surface height of 20 mm is required, specify "SC 0". ■Space for removing UCMSF80 - 25 - K UCMSF80 - 25 - SC60 erUCMSF80 - 25 - WC120 UCMSF80 - 25 - SC30 - WC100 - N16 - K For machining details or tapping hole and dowel hole (prepared hole and finished hole) for mounting of the retainer, refer to page 561. For detailed...

Open the catalog to page 8
UCMSC - 9

Aerial Cam Unit( FOR PIERCE Catalog No. (W) (9)UCMSF 80 — 30 ■Option of SC or WC Option Code 0 When ordering WC, set the position of the piercing center within the cam width. ^Attaching the SC and WC options raises the mounting surface height 20 mm. If only a mounting surface height of 20 mm is required, specify "SC 0". ■Space for removing UCMSF80 - 30 - K UCMSF80 - 30 - SC60 erUCMSF80 - 30 - WC120 UCMSF80 - 30 - SC30 - WC100 - N16 - K For machining details or tapping hole and dowel hole (prepared hole and finished hole) for mounting of the retainer, refer to page 561. For...

Open the catalog to page 9
UCMSC - 10

Aerial Cam Unit( FOR PIERCE Option Code 0 When ordering WC, set the position of the piercing center within the cam width. UCMSF80 - 35 - K UCMSF80 - 35 - SC60 erUCMSF80 - 35 - WC120 UCMSF80 - 35 - SC30 - WC100 - N16 - K For machining details or tapping hole and dowel hole (prepared hole and finished hole) for mounting of the retainer, refer to page 561. For detailed specification of the key, refer to page 880. ^Attaching the SC and WC options raises the mounting surface height 20 mm. If only a mounting surface height of 20 mm is required, specify "SC 0". ■Space for removing 0 Bolts for...

Open the catalog to page 10

All Sankyo Oilless Industry catalogs and technical brochures

  1. UCNBK100

    16 Pages

  2. UCNBK200

    16 Pages

  3. UCNBK65

    16 Pages

  4. SOUK200

    16 Pages

  5. SOUK100

    16 Pages

  6. SOUK65

    16 Pages

  7. UCMSC F150

    17 Pages

  8. UCMSC150

    17 Pages

  9. UCMSC80

    17 Pages

  10. UCMSC65

    16 Pages

  11. UCMSC50

    16 Pages

  12. HUCTF

    17 Pages

  13. SULNC

    8 Pages

  14. SACE

    14 Pages

  15. SUCD

    18 Pages

  16. SACLB80

    2 Pages

  17. SESF

    1 Pages

  18. SACD

    14 Pages

  19. SLSD

    12 Pages

  20. SESW / SESWT

    1 Pages

  21. TSP

    1 Pages

  22. Feed Sensor

    1 Pages

  23. HLSGC

    1 Pages

  24. CBSL, CBSPL

    1 Pages

  25. Guide pin

    1 Pages

  26. SOB

    4 Pages

  27. SBLT

    1 Pages