video corpo

Type 2406 Excess Pressure Valve
6Pages

{{requestButtons}}

Catalog excerpts

Type 2406 Excess Pressure Valve - 1

T 2522 EN Type 2406 Excess Pressure Valve Self-operated Pressure Regulators Application Excess pressure valve for set points from 5 mbar to 10 bar · Nominal size DN 15 to 50 · Nominal pressure PN 16 to 40 Suitable for gases at temperatures from –20 to +60 °C (0 to +150 °C) 1) This regulator is used to control the pressure of flammable gases used as a source of energy, e.g. in boilers, driers, vaporizers, heat exchangers or industrial ovens. Alternatively, it can control the compressed air supply in process engineering applications. An additional application of the regulator is the pressure control of inert gas used for inerting or blanketing reaction or storage tanks to protect the product in the tank from oxidation, explosion or escaping. To achieve an economical consumption of the inert gas, its pressure must be controlled to always remain slightly higher than atmospheric pressure while the tank is being filled or emptied. Special features •• Low-maintenance proportional regulators •• Compact regulator design providing excellent control accuracy •• Internal set point springs with set point adjustment using a nut on the actuator •• Spring-loaded, single-seated valve balanced by a balancing diaphragm Fig. 1: Type 2406 Excess Pressure Valve •• External connection of a control line •• Fulfills stricter fugitive emission requirements •• Minimum leakage class IV •• Suitable for use as a vacuum breaker Version Valve DN 15 to 50 · Flanged connections · Soft-seated plug Body made of cast iron, spheroidal graphite iron, cast steel, stainless cast steel or stainless forged steel Special versions •• Version with FDA-compliant materials for the food and pharmaceutical industries •• NACE version for sour gas applications •• Actuator with seal and leakage line connection (also as vacuum breaker) •• Version with connected control line. Pressure tapped directly at the valve body For unbalanced versions with FKM diaphragm or FKM soft seal SAMSON AKTIENGESELLSCHAFT · Weismüllerstraße 3 · 60314 Frankfurt am Main, Germany Phone: +49 69 4009-0 · Fax: +49

Open the catalog to page 1
Type 2406 Excess Pressure Valve - 2

Principle of operation The medium flows through the valve in the direction indicated by the arrow. The position of the plug determines the flow rate across the area released between plug (3) and valve seat (2). In the pressureless state (control line not connected and no pressure applied) the valve is closed by the force of the set point spring (7). The upstream pressure p1 to be controlled is tapped upstream of the valve and transmitted over the control line 1) to the actuator where it is converted into a positioning force. This force is used to move the valve plug according to the force...

Open the catalog to page 2
Type 2406 Excess Pressure Valve - 3

Table 1: Technical data Installation The regulator is preferably to be installed in horizontal pipelines: - Actuator housing on top, actuator facing upwards - Direction of flow must match the direction indicated by the arrow on the body. - In applications in which the blanketing gas can liquefy, condensate may form in the control line, causing damage to the regulator. To allow condensate to run back into the tank, install the control line with an approximate 10 % slope to the pressure tapping point at the tank. - Distance between the pressure tapping point and regulator min. 2 x DN In...

Open the catalog to page 3
Type 2406 Excess Pressure Valve - 4

Control line connection G ¼ for A = 640 and 1200 cm² Control line connection The control line connection is turned by 90° in the drawing. The connection is normally located opposite the side with the arrow indicating the direction of flow.

Open the catalog to page 4
Type 2406 Excess Pressure Valve - 5

Table 3:  Dimensions in mm and weights in kg Nominal size Other materials Height H Without balancing With balancing Without balancing With balancing Without balancing With balancing Without balancing With balancing Without balancing With balancing Without balancing With balancing Without balancing With balancing Without balancing With balancing Without balancing With balancing

Open the catalog to page 5
Type 2406 Excess Pressure Valve - 6

Ordering text Type 2406 Excess Pressure Valve Nominal size DN ..., set point range … mbar (bar), KVS coefficient … Body material …, optionally, special version ... Materials: Specifications subject to change without notice Plug seal ..., balancing diaphragm ..., operating diaphra

Open the catalog to page 6

All SAMSON catalogs and technical brochures