video corpo

Type 2375 Excess Pressure Valve for corrosive media
4Pages

{{requestButtons}}

Catalog excerpts

Type 2375 Excess Pressure Valve for corrosive media - 1

T 2536 EN Type 2375 Excess Pressure Valve for corrosive media Self-operated Pressure Regulators Application Pressure regulators for set points from 0.8 to 16 bar · Valve nominal sizes DN 15 to 501) · Nominal pressure PN 40 Suitable for gases and liquids up to 80 °C The valve opens when the upstream pressure rises. The Type 2375 Excess Pressure Valve regulates the upstream pressure to the adjusted set point within the range from 0.8 to 16 bar. Special features •• Low-maintenance proportional regulators requiring no auxiliary energy •• All wetted parts free of non-ferrous metal •• Wide set point range and convenient set point adjustment using a nut •• Soft-seated plug for high shut-off requirements Versions Type 2375 Excess Pressure Valve, consisting of: Nominal size DN 15, 20, 25, 32, 40, and 50 · Actuator with rolling diaphragm made of EPDM, FPM or NBR · Valve with body made of corrosion-resistant steel 1.4470 ANSI version Special version With special materials for applications involving sea water: 1.4538, duplex steel 1.4469 · Nickel-base alloy: 9.4610 Flanges in higher pressure ratings · Other special materials on request · With metal cover (to protect the set point springs) Accessories Screw fitting for control line connection · Control line kit available for tapping the pressure directly at the valve body Larger valve sizes on request Fig. 1: Type 2375 Excess Pressure Valve SAMSON AKTIENGESELLSCHAFT · Weismüllerstraße 3 · 60314 Frankfurt am Main, Germany Phone: +49 69 4009-0 · Fax: +49 69 4009-1507 · samson@samson

Open the catalog to page 1
Type 2375 Excess Pressure Valve for corrosive media - 2

Principle of operation The medium flows through the valve (1) as indicated by the arrow. The position of the plug (3) determines the flow rate across the area released between plug and valve seat (2). The set point springs (7) are loaded by the set point adjuster (6). When relieved of pressure (p1 = p2), the valve is closed by the force of the set point springs. The upstream pressure p1 to be controlled is tapped upstream of the valve and transmitted over the control line (14) to the operating diaphragm (12) where it is converted into a positioning force. This force is used to move the...

Open the catalog to page 2
Type 2375 Excess Pressure Valve for corrosive media - 3

Table 1:  Technical data · All pressure stated as gauge pressure Type 2375 Excess Pressure Valve Nominal size Nominal pressure Max. permissible differential pressure ∆p Leakage class according to IEC 60534‑4 Metal seal Soft seal Actuator Set point ranges Actuator area Max. perm. pressure at actuator 40 cm²|6 in² 80 cm²|12 in² Larger valve sizes on request 20 °C for sea water (approx. 3.5 % salt content) with duplex 1.4462/1.4470 or 40 °C with super duplex 1.4410/1.4469 Table 2:  Materials · Material numbers according to DIN EN Valve Valve body Cast stainless steel 1.4470 Stainless steel...

Open the catalog to page 3
Type 2375 Excess Pressure Valve for corrosive media - 4

Table 4:  Dimensions in mm and weights in kg Type 2375 Excess Pressure Valve Nominal size Valve dimensions Actuator housing Actuator housing Height H Actuator housing Actuator housing Weight , approx. Actuator housing The weights are based on the weight of the regulator with actuator area A = 80 cm². Add 4 kg for A = 160 cm². Ordering text Type 2375 Excess Pressure Valve DN …, PN … Set point range ... bar Optionally, accessories ... Specifications subject to change witho

Open the catalog to page 4

All SAMSON catalogs and technical brochures