T 5576 EN TROVIS 5576 Heating and District Heating Controller Application Control of max. two control circuits. To control more circuits, several controllers can be linked by a device bus. The controller can communicate with up to six heat meters using the retrofittable meter bus plug-in module. The TROVIS 5576 Heating and District Heating Controller is used to control max. two control circuits: Control of a primary heat exchanger or boiler with max. one mixing and one non-mixing heating circuit (both outdoor-temperature-compensated) as well as control of DHW heating in the secondary circuit Electronics from SAMSON –– Control of one outdoor-temperature-compensated heating circuit and a DHW heating with two valves in the primary circuit –– Control of two outdoor-temperature-compensated heating circuits with two valves in the primary circuit Properties •• Rotary switches for direct access to the operating modes and essential parameters of the control circuits •• Intuitive data retrieval and input by pressing and turning the pushbutton •• Illuminated display •• 365-day clock with max. four time schedules and automatic summer time/winter time changeover; maximum three times-of-use per day (input in steps of 15 minutes) •• Room panels may be connected for each heating circuit: –– Convenient room panels for adjustment of the operating mode, the day and night set points, the times-ofuse for heating, the controller clock and party mode. Additional outdoor and room temperature readings. Connection via device bus –– Room panel to override operating mode and rated room temperature •• Demand-driven control by set point demand by subsequent controllers over a device bus or 0 to 10 V signal. The primary circuit controls the maximum flow temperature demanded plus adjustable boost. •• Applications with solar hot water system available Fig. 1: TROVIS 5576 Heating and District Heating Controller SAMSON AKTIENGESELLSCHAFT · Weismüllerstraße 3 · 60314 Frankfurt am Main, Germany Phone: +49 69 4009-0 · Fax: +49 69 4009-1507 ·
Open the catalog to page 1•• Instantaneous heating systems with water flow sensor configurable •• Heating characteristics optionally based on the gradient or based on four points; variable return flow temperature limitation •• Adaptation: automatic adaptation of the heating characteristic (room temperature sensor required) •• Optimization: calculation of the best possible activation and deactivation times for the heating (room temperature sensor required) •• Drying of jointless floors function with adjustable parameter settings •• Pump management function: speed changeover for a heating circulation pump available ••...
Open the catalog to page 2For systems with two control circuits and five pumps, the second heating circuit can only use the 0 to 10 V output. Electrical connection and installation The controller consists of the housing containing the electronics and a separate terminal board for electrical connection. Two wires of max. 1.5 mm2 may be connected to each terminal. The sensor connection lines must be installed separately from the lines carrying the power supply. For wall mounting, screw the terminal board to the wall. After wiring the controller, place the controller housing onto the terminal board and fasten it with...
Open the catalog to page 3Terminal assignment Pump management - COM UP on/off UP Speed + Operating voltage - for TROVIS 5570*1 Device bus Meter bus*1 27 Meter bus*1 28 Device bus NOTICE Never connect terminals 18 (ground for sensor), 19 (ground for 0 to 10 V/0 to 20 mA) and 20 (ground for 0 to 10 V control outputs). 1) 2) If the controller is equipped with a meter bus plug-in module, the TROVIS 5570 Room Panel cannot be supplied by the controller. A 50 Ω resistor is required between terminals 17 and 19 for applying a 20 mA signal. Fig. 3: Terminal assignment of the TROVIS 5576 Heating and District Heating Controller...
Open the catalog to page 4All SAMSON catalogs and technical brochures
-
TROVIS 5590 Web Module
2 Pages
-
Room Controller TROVIS 5572
2 Pages
-
Room Panel TROVIS 5570
2 Pages
-
Line Splitter TROVIS 5486
2 Pages
-
Type 9 Temperature Regulator
6 Pages
-
Type 8 Temperature Regulator
6 Pages
-
Type 5 D Boiler Controller
2 Pages
-
Rotary Plug Valve Type 62.7
7 Pages
-
Actuator Type S
3 Pages
-
Actuator Type MZ
4 Pages
-
Actuator Type MN
3 Pages
-
Actuator Type MD
3 Pages
-
Actuator Type R
3 Pages
-
Actuator Type AT
4 Pages
-
Rotary Plug Valve Type 82.7
7 Pages
-
Rotary Plug Valve Type 73.7
7 Pages
-
Rotary Plug Valve Type 73.3
7 Pages
-
Rotary Plug Valve Type 72.4
7 Pages
-
Rotary Plug Valve Type 72.3
8 Pages
-
SAMSON Positioners
28 Pages
Archived catalogs
-
T21 11
6 Pages