T 5573 EN TROVIS 5573 Heating and District Heating Controller Application Control of max. two control circuits The TROVIS 5573 Heating and District Heating Controller is used to control max. two control circuits: –– Control of a primary heat exchanger or boiler with max. one mixing and one non-mixing heating circuit (both weather-compensated) as well as control of DHW heating in the secondary circuit Electronics from SAMSON TROVIS 5573-0 with icon readings on the display –– Weather-compensated buffer storage tank control with solid-fuel boiler or solar circuit control –– Control of one weather-compensated heating circuit and a DHW heating with two valves in the primary circuit –– Control of two weather-compensated heating circuits with two valves in the primary circuit Versions –– TROVIS 5573-000x: Controller with icon readings on the display TROVIS 5573-1 with plain-text readings on graphics display –– TROVIS 5573-100x: Controller with plain-text readings on the graphics display –– TROVIS 5573-110x: Controller with graphics display and M-bus interface for three M-bus units Special features •• Rotary switches for direct access to the operating modes and essential parameters of the control circuits •• Intuitive data retrieval and input by pressing and turning the pushbutton •• 365-day clock with max. four time schedules and automatic summer time/winter time changeover; maximum three times-of-use per day (input in steps of 15 minutes) •• Room panels connected to individual heating circuits to override operating mode and rated room temperature •• Demand-driven control by set point demand by subsequent controllers over a 0 to 10 V signal: the primary circuit controls the maximum flow temperature demanded plus adjustable boost. Fig. 1: TROVIS 5573 Heating and District Heating Controller •• Heating characteristics optionally based on the gradient or based on four points; variable return flow temperature limitation •• Adaptation: automatic adaptation of the heating characteristic (room temperature sensor required) •• Optimization: calculation of the best possible activation and deactivation times for the heating (room temperature sensor required) •• Drying of jointless floors function with adjustable parameter settings •• Updatable flash memory in controller (operating system) SAMSON AKTIENGESELLSCHAFT · Weismüllerstraße 3 · 60314 Frankfurt am Main, Germany Phone: +49 69 4009-0 · Fax: +49
Open the catalog to page 1•• Configuration and parameterization using a memory module •• Data logging function: –– Operating data can be saved to a data logging module –– Data can be displayed in the data log viewer on the PC –– TROVIS 5573-1: analysis on the graphics display of the data saved in the operating data memory Operation The TROVIS 5573 Heating and District Heating Controller is adapted to the specific system by setting the appropriate system code number. To select the code number, refer to the system schematics described in the associated mounting and operating instructions. Additional sensors and/or...
Open the catalog to page 2* For systems with one control circuit, a maximum of four pumps are avai lable Controller with standard base Controller with high base
Open the catalog to page 3Fig. 3: Terminal assignment of TROVIS 5573 Controller with standard base Fig. 4: Terminal assignment of TROVIS 5573 Controller with high base Outdoor sensor Solar circuit pump Binary input Control circuit Circulation pump (heating) Storage tank charging pump Heat exchanger charging pump Storage tank sensor Flow sensor Specifications subject to change without notice Room sensor
Open the catalog to page 4All SAMSON catalogs and technical brochures
-
TROVIS 5590 Web Module
2 Pages
-
Room Controller TROVIS 5572
2 Pages
-
Room Panel TROVIS 5570
2 Pages
-
Line Splitter TROVIS 5486
2 Pages
-
Type 9 Temperature Regulator
6 Pages
-
Type 8 Temperature Regulator
6 Pages
-
Type 5 D Boiler Controller
2 Pages
-
Rotary Plug Valve Type 62.7
7 Pages
-
Actuator Type S
3 Pages
-
Actuator Type MZ
4 Pages
-
Actuator Type MN
3 Pages
-
Actuator Type MD
3 Pages
-
Actuator Type R
3 Pages
-
Actuator Type AT
4 Pages
-
Rotary Plug Valve Type 82.7
7 Pages
-
Rotary Plug Valve Type 73.7
7 Pages
-
Rotary Plug Valve Type 73.3
7 Pages
-
Rotary Plug Valve Type 72.4
7 Pages
-
Rotary Plug Valve Type 72.3
8 Pages
-
SAMSON Positioners
28 Pages
Archived catalogs
-
T21 11
6 Pages