video corpo

Self-operated Temperature Regulators Type 1u Temperature Regulator
6Pages

{{requestButtons}}

Catalog excerpts

Self-operated Temperature Regulators Type 1u Temperature Regulator - 1

Self-operated Temperature Regulators Type 1u Temperature Regulator ANSI version Application Temperature regulators for cooling installations · Control thermostats for set points1) from 15 to 480 °F (–10 to 250 °C) · Valves in NPS ½ to 2 · Pressure ratings Class 125 to 300 · Suitable for liquids up to 300 °F (150 °C) and gases up to 175 °F (80 °C) The valve opens when the temperature rises. The regulators consist of a valve with flanged connections and a control thermostat, comprising a temperature sensor, set point adjuster with excess temperature protection, capillary tube and operating element. Special features • Low-maintenance P-regulators requiring no auxiliary energy • Wide set point range and convenient set point adjustment on a scale • Globe valves with plug balanced by a bellows (NPS 1½ to 2) • Suitable for liquids, particularly for cooling media, e.g. cooling water and brine Versions Type 1u Temperature Regulator · With Type 2121 Valve with flanged connection · Class 125 to 300 · Type 2231 to 2234 Control Thermostat · Unbalanced valve (NPS ½ to 2) · Balanced valve (NPS 1½ to 2) · Opening Refer to Information Sheet T 2010 EN for details on the application of control thermostats. Type 2121/2231 · With Type 2231 Control Thermostat for liquids · Set point adjustment at the sensor · Set points 1) from 15 to 300 °F (–10 to +150 °C) Type 2121/2232 (Fig. 1) · With Type 2232 Control Thermostat for liquids and steam · Separate set point adjustment · Set points1) from 15 to 480 °F (–10 to +250 °C) Type 2121/2233 · With Type 2233 Control Thermostat for liquids, air and gases · Set point adjustment on the sensor · Set points from 15 to 300 °F (–10 to +150 °C) Type 2121/2234 · With Type 2234 Control Thermostat for liquids, steam, air and gases · Separate set point adjustment · Set points from 15 to 480 °F (–10 to +250 °C) Special versions for set points from –40 to 160 °F (–40 to 60 °C) Associated Data Sheet Fig. 1 · Type 1u Temperature Regulator with Type 2232 Control Thermostat Special versions • Capillary tube 16, 33 or 50 ft (5, 10 or 15 m) • Sensor of CrNiMo steel • Capillary tube of CrNiMo steel or plastic-coated copper • Version with minimum flow rate • Plug with PTFE seal • Valve free of non-ferrous metal • Valve completely of corrosion-resistant material • Version for oil at max. permis

Open the catalog to page 1
Self-operated Temperature Regulators Type 1u Temperature Regulator - 2

Principle of operation (see Fig. 2) The regulators operate according to the liquid expansion principle. Temperature sensor (13), capillary tube (10) and operating element (7) are filled with an expansion liquid. The liquid changes its volume depending on the temperature, causing the operating element (7) and thus the valve's plug stem (5) with the plug (3) to move. The position of the plug determines the flow rate of the heat transfer medium across the area released between the plug and seat (2). The temperature set point can be adjusted using a key (11) to a value that can be read off the...

Open the catalog to page 2
Self-operated Temperature Regulators Type 1u Temperature Regulator - 3

Table 2 • Materials ■ Material designations according to ASTM and DIN EN 1 Special version 1.4305 with EPDM or FPM soft seal or metal-seated 2) Stainless steel 1.4408 or CC499K (Rg 5) available on request Installation Valve Install the valve in a horizontal pipeline. Make sure the direction of flow corresponds to the arrow on the body. The operating element must be suspended. If necessary, the operating element can also be installed to point up (see EB 2111/... 2123 EN). Temperature sensor The temperature sensor can be installed in any desired position. Make sure, however, that its entire...

Open the catalog to page 3
Self-operated Temperature Regulators Type 1u Temperature Regulator - 4

Dimensions · Control thermostats, valves, accessories Type 1u Temperature Regulator with Type 2231 or 2233 Control Thermostat Types 2232/2234 Control Thermostats Type 2232/2234 Control Thermostat with separate set point adjustment Type 2121 with flanged connections Type 2231/2233 Control Thermostat Dimensions and weights · Control thermostats Type … Control Thermostat Immersion depth T Approx. weight 1) Larger immersion depths available on request Dimensions and weights · Valves Type 2121 Valve Valve size Class 125 Face-toface Class 150 length L Class 300 Height H Height H1 Height H2...

Open the catalog to page 4
Self-operated Temperature Regulators Type 1u Temperature Regulator - 5

Dimensions · Accessories Thermowells for Types 2231/2232 Control Thermostat Type ... Mounting parts for Types 2233/2234 2232 9.7“ Clamps and perforated cover for wall mounting with flanged connection NPS 1 ½/Class 150 Thermowell with threaded connection 1 NPT/Class 150 Thermowells for flammable gases, 1 NPT/Class 600 Control thermostat Length L1 Extension piece/separating piece G1¼ Extension piece: Standard version L = approx. 5.5“ (140 mm), approx. 1.1 lb (0.5 kg) Special version (with bellows seal) L = approx. 7.1“ (180 mm), approx. 1.3 lb (0.6 kg) Separating piece: with seals Thermowell...

Open the catalog to page 5
Self-operated Temperature Regulators Type 1u Temperature Regulator - 6

A separating piece must be used when a seal between thermostat and valve is required. Separating pieces made of CrNi steel must be used when all wetted parts are to be free of non-ferrous metals. In addition, it prevents the medium from leaking while the thermostat is being replaced. Manual adjuster Ma with travel indicator • MaS with electric signal transmitter Types 2231 and 2232 Bulb Sensors: thermowells with threaded connection Types 2233 and 2234 Bulb Sensors: clamps and perforated cover for wall mounting Ordering text Temperature Regulator Type 1u NPS ... Body in Class ... with...

Open the catalog to page 6