Catalog excerpts
SLC X-PERT Uninterruptible power supplies 80 to 400 kVA
Open the catalog to page 1High critical power facilities protected by high functionalities Salicru's SLC X-PERT series consists of three-phase UPSs that combine very low total cost of ownership (TCO) with very high efficiency and compact design, providing high-quality uninterruptible power supply for all critical applications. The technology incorporated offers one of the highest efficiencies on the market in VFI mode and 100% of expected battery life. The SLC X-PERT series maximises the use of the floor area occupied thanks to its high power density design. Models from 200 kVA have complete front access, precluding...
Open the catalog to page 2High-efficiency mode Dedicated electronic devices and control algorithm, which allow the batteries to be dynamically isolated from the device’s DC bus so that the inverter can be powered at a lower DC voltage. Ability to parallel systems with up to 6 units (allowing up to 2.4 MW of power to be reached), both for redundant systems, and to increase power capacity. By working at a lower DC voltage, inverter switching losses are drastically reduced, and high energy efficiency of up to 97% is obtained, now from low percentages of output load. N+M redundant systems enable critical loads that...
Open the catalog to page 3Redundant internal power supply The device has a redundant power supply for control and the static bypass switch. In the event of the failure of the main power supply, the redundant power source keeps the microprocessor of the control panel powered and excitations necessary to maintain the static bypass connected to the output. Ensure the continuity of power even in the event of failure of the device itself, providing maximum availability. Front maintenance All electronic and electrical components that are susceptible to failure or require preventative maintenance are positioned to enable...
Open the catalog to page 4Internal batteries The standard backup of the 80 kVA device is located in the same device cabinet. Intermittent battery charging; battery insulation with respect to voltage ripple caused by distorting loads; temperature compensation of float voltage; manual and automatic battery test. Allows the floor area occupied to be reduced, resulting in lower TCO. Prolongation of battery life. Temperature compensation prevents excessive recharging and unnecessary overheating of the batteries. Shared battery Battery test to detect possible failures early and ensure availability. Battery capacity*...
Open the catalog to page 5Open to the world 10” touch screen 10”colour touch screen containing all information about the device’s measurements, alarm situations and operating states. With schematic diagram of operation. Choice of 8 languages. Ease of handling, complete information. Compatibility with power generators INPUT VOLTAGE The UPS’s peak startup currents can be reduced with different settings: sequential startup of the two internal stages (thyristors and PFC), as well as sequential startup in parallel systems (configurable startup time), programmable soft startup time (walk-in time), deactivation of battery...
Open the catalog to page 6Optional extras Parallel/redundant kit Kit for installations with growth needs in power or redundancy in the power supply, enabling the interconnection of different units/systems. Ethernet/SNMP adapter SNMP adapter, which enables the device to be integrated into a computer network using an IP address. Includes adapter, CD containing programming software, configuration cable, Management Information Base (MIB) and user manual. Available in card or box format. MODBUS protocol Public and industrial communications protocol that allows the device to be controlled and monitored. With communication...
Open the catalog to page 7Range MODEL BATT DIMENSIONS BATT WEIGHT Batteries located in cabinets. Nomenclature, dimensions and weights for devices with input voltage 3 x 400 V, output voltage 3 x 400 V and standard backup. BATT DIMENSIONS BATT WEIGHT Batteries located in racks. Nomenclature, dimensions and weights for devices with input voltage 3 x 400 V, output voltage 3 x 400 V and standard backup. Heat losses MODEL
Open the catalog to page 8Information subject to change without notice. (1) Ni-Cd, Li-Ion and other types of battery on request. (2) Power degradation for higher altitudes up to a maximum of 5,000 masl.
Open the catalog to page 9Applications In today’s world, information and the technologies and systems associated with it have high strategic value, but they also have one thing in common: they are all dependent on a high-quality, stable power supply to ensure uninterrupted enjoyment of the benefits they offer. To make this possible, Salicru has the most optimum solutions to ensure its integrity and maximum protection at all times in the different critical sectors of society: Data centres The cost of critical elements in data availability (hosting, housing, parcel delivery, airline reservations, etc.) and the cost...
Open the catalog to page 10Comprehensive service available to customers The day-to-day running of your business must not be allowed to be interrupted by an incident in your uninterruptible power supply (UPS). Salicru puts at your disposal its Technical Service & Support (TSS) department, with its extensive network of qualified technicians who can provide assistance in the event of any eventuality or incident with your device, regardless of location, day or time. Our goal is your peace of mind and satisfaction, providing you with the reassurance that Salicru will resolve any issues that may arise. A business's...
Open the catalog to page 11REF JJ048B01 CODE 401AB001139 ED FEBRUARY 2020 - SLC X-PERT CATALOGUE OFFICES AND TECHNICAL SERVICE AND SUPPORT CENTRES (TSS) ALICANTE BARCELONA BILBAO CORUNNA GIJON SUBSIDIARIES CHINA FRANCE REST OF THE WORLD ALGERIA ANDORRA ARGENTINA AUSTRIA BAHREIN BANGLADESH BELARUS BELGIUM BOLIVIA BRAZIL BULGARIA CHILE COLOMBIA CUBA CYPRUS CZECH REPUBLIC DENMARK LAS PALMAS DE G. CANARIA MADRID MALAGA PALMA DE MALLORCA SAN SEBASTIAN SANTA CRUZ DE TENERIFE SEVILLE VALENCIA ZARAGOZA HUNGARY MOROCCO MEXICO PERU ECUADOR EGYPT EQUATORIAL GUINEA ESTONIA FINLAND GERMANY GREECE GUATEMALA HOLLAND INDONESIA IRAN...
Open the catalog to page 12All SALICRU catalogs and technical brochures
-
SPS NODE
4 Pages
-
SPS NET2
2 Pages
-
EQUINOX2 T
4 Pages
-
EQUINOX
20 Pages
-
SLC ADAPT2
4 Pages
-
SLC ADAPT / 2 catalogue
16 Pages
-
Rechargeable AGM battery
4 Pages
-
EQUINOX2 S/SX
4 Pages
-
DC power S
4 Pages
-
DC power L
4 Pages
-
NS
2 Pages
-
EMi3
4 Pages
-
CV30-PV
4 Pages
-
SLC CUBE4
4 Pages
-
EQUINOX2 HT
4 Pages
-
RE3
4 Pages
-
SLC CUBE4 Catalogue
16 Pages
-
CONTROLVIT
32 Pages
-
EQUINOX2 HSX
4 Pages
-
SLC ADAPT
4 Pages
-
SLC TWIN PRO2 0-3K
4 Pages
-
SLC CUBE3+
4 Pages
-
VR EQX
4 Pages
-
CS IS
2 Pages
-
CV50
4 Pages
-
SPS ONE
4 Pages
-
SALICRU General Catalogue
204 Pages
-
SLC TWIN RT3 4-10 kVA
4 Pages
-
SLC TWIN RT3 1-3 KVA
4 Pages
-
CV30
4 Pages
-
CV10
4 Pages
-
ACV30-PV
4 Pages
-
Homes, offices & shops
4 Pages
-
Industry
4 Pages
-
Infrastructures and energy
4 Pages
-
Telecominications
4 Pages
-
Energy and renewables
4 Pages
-
SLC TWIN PRO3 4-10 kVA
4 Pages
-
SPS.ATS
2 Pages
-
SLC TWIN RT2 LION
4 Pages
-
SLC XPERT
4 Pages
-
IT Transformers
2 Pages
-
SLC X-TRA
4 Pages
-
ARC
2 Pages
-
SPS HOME
4 Pages
-
SPS ADVANCE RT2
4 Pages
-
SPS SOHO
4 Pages
-
SPS ADV R
4 Pages
-
SPS ADV T
4 Pages
-
SPS NET
2 Pages
-
SPS SAFE
2 Pages
-
CF CUBE3+
4 Pages
-
SPS PDU
2 Pages
-
SOFTWARE
2 Pages
-
BACS
4 Pages
-
SLC CUBE3+ Catalogue
8 Pages
-
SLC X-TRA Catalogue
12 Pages
Archived catalogs
-
ILUEST+ MT
4 Pages
-
IT M
4 Pages
-
EQUINOX S
4 Pages
-
EQUINOX TL
4 Pages
-
EQUINOX TM
4 Pages
-
ILUEST+ CR
4 Pages
-
SLC TWIN RT2 0-3kVA
4 Pages
-
SLC TWIN PRO2 4-20kVA
4 Pages
-
SLC ADAPT
2 Pages
-
SLC TWIN PRO
2 Pages
-
FAC P
2 Pages
-
OPTIMUS
2 Pages
-
SLC ADAPT
2 Pages
-
ILUEST+ Catalogue
12 Pages
-
RE brochure
2 Pages
-
EMi2 brochure
2 Pages
-
Brochure SLC CUBE3
2 Pages
-
Catalogue SLC-CUBE3
12 Pages