video corpo

SLC XPERT catalogue
12Pages

{{requestButtons}}

Catalog excerpts

SLC XPERT catalogue - 1

SLC X-PERT Uninterruptible power supplies 80 to 400 kVA

Open the catalog to page 1
SLC XPERT catalogue - 2

High critical power facilities protected by high functionalities Salicru's SLC X-PERT series consists of three-phase UPSs that combine very low total cost of ownership (TCO) with very high efficiency and compact design, providing high-quality uninterruptible power supply for all critical applications. The technology incorporated offers one of the highest efficiencies on the market in VFI mode and 100% of expected battery life. The SLC X-PERT series maximises the use of the floor area occupied thanks to its high power density design. Models from 200 kVA have complete front access, precluding...

Open the catalog to page 2
SLC XPERT catalogue - 3

High-efficiency mode Dedicated electronic devices and control algorithm, which allow the batteries to be dynamically isolated from the device’s DC bus so that the inverter can be powered at a lower DC voltage. Ability to parallel systems with up to 6 units (allowing up to 2.4 MW of power to be reached), both for redundant systems, and to increase power capacity. By working at a lower DC voltage, inverter switching losses are drastically reduced, and high energy efficiency of up to 97% is obtained, now from low percentages of output load. N+M redundant systems enable critical loads that...

Open the catalog to page 3
SLC XPERT catalogue - 4

Redundant internal power supply The device has a redundant power supply for control and the static bypass switch. In the event of the failure of the main power supply, the redundant power source keeps the microprocessor of the control panel powered and excitations necessary to maintain the static bypass connected to the output. Ensure the continuity of power even in the event of failure of the device itself, providing maximum availability. Front maintenance All electronic and electrical components that are susceptible to failure or require preventative maintenance are positioned to enable...

Open the catalog to page 4
SLC XPERT catalogue - 5

Internal batteries The standard backup of the 80 kVA device is located in the same device cabinet. Intermittent battery charging; battery insulation with respect to voltage ripple caused by distorting loads; temperature compensation of float voltage; manual and automatic battery test. Allows the floor area occupied to be reduced, resulting in lower TCO. Prolongation of battery life. Temperature compensation prevents excessive recharging and unnecessary overheating of the batteries. Shared battery Battery test to detect possible failures early and ensure availability. Battery capacity*...

Open the catalog to page 5
SLC XPERT catalogue - 6

Open to the world 10” touch screen 10”colour touch screen containing all information about the device’s measurements, alarm situations and operating states. With schematic diagram of operation. Choice of 8 languages. Ease of handling, complete information. Compatibility with power generators INPUT VOLTAGE The UPS’s peak startup currents can be reduced with different settings: sequential startup of the two internal stages (thyristors and PFC), as well as sequential startup in parallel systems (configurable startup time), programmable soft startup time (walk-in time), deactivation of battery...

Open the catalog to page 6
SLC XPERT catalogue - 7

Optional extras Parallel/redundant kit Kit for installations with growth needs in power or redundancy in the power supply, enabling the interconnection of different units/systems. Ethernet/SNMP adapter SNMP adapter, which enables the device to be integrated into a computer network using an IP address. Includes adapter, CD containing programming software, configuration cable, Management Information Base (MIB) and user manual. Available in card or box format. MODBUS protocol Public and industrial communications protocol that allows the device to be controlled and monitored. With communication...

Open the catalog to page 7
SLC XPERT catalogue - 8

Range MODEL BATT DIMENSIONS BATT WEIGHT Batteries located in cabinets. Nomenclature, dimensions and weights for devices with input voltage 3 x 400 V, output voltage 3 x 400 V and standard backup. BATT DIMENSIONS BATT WEIGHT Batteries located in racks. Nomenclature, dimensions and weights for devices with input voltage 3 x 400 V, output voltage 3 x 400 V and standard backup. Heat losses MODEL

Open the catalog to page 8
SLC XPERT catalogue - 9

Information subject to change without notice. (1) Ni-Cd, Li-Ion and other types of battery on request. (2) Power degradation for higher altitudes up to a maximum of 5,000 masl.

Open the catalog to page 9
SLC XPERT catalogue - 10

Applications In today’s world, information and the technologies and systems associated with it have high strategic value, but they also have one thing in common: they are all dependent on a high-quality, stable power supply to ensure uninterrupted enjoyment of the benefits they offer. To make this possible, Salicru has the most optimum solutions to ensure its integrity and maximum protection at all times in the different critical sectors of society: Data centres The cost of critical elements in data availability (hosting, housing, parcel delivery, airline reservations, etc.) and the cost...

Open the catalog to page 10
SLC XPERT catalogue - 11

Comprehensive service available to customers The day-to-day running of your business must not be allowed to be interrupted by an incident in your uninterruptible power supply (UPS). Salicru puts at your disposal its Technical Service & Support (TSS) department, with its extensive network of qualified technicians who can provide assistance in the event of any eventuality or incident with your device, regardless of location, day or time. Our goal is your peace of mind and satisfaction, providing you with the reassurance that Salicru will resolve any issues that may arise. A business's...

Open the catalog to page 11
SLC XPERT catalogue - 12

REF JJ048B01 CODE 401AB001139 ED FEBRUARY 2020 - SLC X-PERT CATALOGUE OFFICES AND TECHNICAL SERVICE AND SUPPORT CENTRES (TSS) ALICANTE BARCELONA BILBAO CORUNNA GIJON SUBSIDIARIES CHINA FRANCE REST OF THE WORLD ALGERIA ANDORRA ARGENTINA AUSTRIA BAHREIN BANGLADESH BELARUS BELGIUM BOLIVIA BRAZIL BULGARIA CHILE COLOMBIA CUBA CYPRUS CZECH REPUBLIC DENMARK LAS PALMAS DE G. CANARIA MADRID MALAGA PALMA DE MALLORCA SAN SEBASTIAN SANTA CRUZ DE TENERIFE SEVILLE VALENCIA ZARAGOZA HUNGARY MOROCCO MEXICO PERU ECUADOR EGYPT EQUATORIAL GUINEA ESTONIA FINLAND GERMANY GREECE GUATEMALA HOLLAND INDONESIA IRAN...

Open the catalog to page 12

All SALICRU catalogs and technical brochures

  1. SPS NODE

    4 Pages

  2. SPS NET2

    2 Pages

  3. EQUINOX2 T

    4 Pages

  4. EQUINOX

    20 Pages

  5. SLC ADAPT2

    4 Pages

  6. DC power S

    4 Pages

  7. DC power L

    4 Pages

  8. NS

    2 Pages

  9. EMi3

    4 Pages

  10. CV30-PV

    4 Pages

  11. SLC CUBE4

    4 Pages

  12. EQUINOX2 HT

    4 Pages

  13. RE3

    4 Pages

  14. CONTROLVIT

    32 Pages

  15. EQUINOX2 HSX

    4 Pages

  16. SLC ADAPT

    4 Pages

  17. SLC CUBE3+

    4 Pages

  18. VR EQX

    4 Pages

  19. CS IS

    2 Pages

  20. CV50

    4 Pages

  21. SPS ONE

    4 Pages

  22. CV30

    4 Pages

  23. CV10

    4 Pages

  24. ACV30-PV

    4 Pages

  25. Industry

    4 Pages

  26. SPS.ATS

    2 Pages

  27. SLC XPERT

    4 Pages

  28. SLC X-TRA

    4 Pages

  29. ARC

    2 Pages

  30. SPS HOME

    4 Pages

  31. SPS SOHO

    4 Pages

  32. SPS ADV R

    4 Pages

  33. SPS ADV T

    4 Pages

  34. SPS NET

    2 Pages

  35. SPS SAFE

    2 Pages

  36. CF CUBE3+

    4 Pages

  37. SPS PDU

    2 Pages

  38. SOFTWARE

    2 Pages

  39. BACS

    4 Pages

Archived catalogs

  1. ILUEST+ MT

    4 Pages

  2. IT M

    4 Pages

  3. EQUINOX S

    4 Pages

  4. EQUINOX TL

    4 Pages

  5. EQUINOX TM

    4 Pages

  6. ILUEST+ CR

    4 Pages

  7. SLC ADAPT

    2 Pages

  8. SLC TWIN PRO

    2 Pages

  9. FAC P

    2 Pages

  10. OPTIMUS

    2 Pages

  11. SLC ADAPT

    2 Pages

  12. RE brochure

    2 Pages