Catalog excerpts
On-line double conversion tower/rack UPS, 1000-3000 VA, with lithium-ion batteries SLC TWIN RT2 LION: Maximum protection density Salicru’s SLC TWIN RT2 LION series are uninterruptible power supply (UPS) systems that offer the most reliable on-line double conversion technology on the market, with output power factor PF=0.9, a format that adapts to suit any tower/rack environment, lithium-ion batteries and a wide range of options for communication. The use of lithium-ion batteries as a backup power source has numerous advantages over traditional valve-regulated lead acid (VRLA) batteries: their lifespan is more than double, they can accommodate up to 10 times more discharge cycles, their rate of self-discharge is four times lower, they can maintain their level of performance at high temperatures (40ºC), they offer reduced weight and volume, and they can be recharged up to four times faster (among other advantages). Applications: Better performance and lower TCO for protecting edge environments With regard to TCO, lithium-ion batteries have a longer useful life than the estimated working life of the UPS (10 years), meaning that unlike VRLA batteries, they do not need to be replaced. Consequently, a slightly higher initial investment is converted into a significant saving by the time the system reaches the end of its life. Adaptable to any edge computing environment, Salicru’s SLC TWIN RT2 LION series offers top-level security in a compact format with a wide range of communication options for IT servers, voice and data networks, video streaming, unified communications, document management and CAD/CA
Open the catalog to page 1Performances ∙ On-line double conversion technology. ∙ Output power factor PF= 0.9. ∙ Convertible tower/rack format. ∙ Control panel with swivel mount LCD display and keypad. ∙ Includes pedestal (pedestal mount) and lugs (rack mount). ∙ Lithium-ion batteries with over 2000 discharge cycles. ∙ RS-232 and USB-HID communication interfaces. ∙ Downloadable monitoring software for Windows, Linux and Mac. ∙ Smart slot for SNMP/potential-free contacts/MODBUS. ∙ ADSL/fax/modem line protection. ∙ Can operate in Eco Mode. ∙ Programmable outputs for critical/non-critical loads. ∙ Frequency conversion...
Open the catalog to page 2Range CODE Frontal protuberance, from the fixing plane of the ears on the rack cabinet: 35mm. This distance is not included in the “Depth” total dimension. 1. Plug (IEC C14 for 1000 and 1500 VA models; IEC C20 for 2000 and 3000 VA models). 2. Sockets (8 x IEC C13), programmable critical (x4) / non-critical (x4). 3. Socket IEC C19 (only for 3000 VA model). 4. ADSL/fax/modem transient protector. 5. USB interface. 6. RS-232 interface. 7. Smart slot for SNMP/potential-free contacts/ MODBUS. 8. Eme
Open the catalog to page 3REF. JJ108B01 CODE 401AB001309 ED. MAY 2022 - UNINTERRUPTIBLE POWER SUPPLY SYSTEMS (UPS) Technical specifications MODEL On-line double-conversion FORMAT INPUT Convertible tower/rack Rated voltage Voltage range Rated frequency Frequency range Total harmonic distortion (THDi) Power factor Rated voltage Voltage accuracy Total harmonic distortion (THDv) ±1% < 2% linear load / < 4% non-linear load Synchronised frequency Free running frequency On-line performance Eco-mode performance Admissible overloads Programmable sockets BYPASS Rated voltage Frequency range ≥90 ÷ 91% ≥96 ÷ 97% < 130% for 5...
Open the catalog to page 4All SALICRU catalogs and technical brochures
-
SPS NODE
4 Pages
-
SPS NET2
2 Pages
-
EQUINOX2 T
4 Pages
-
EQUINOX
20 Pages
-
SLC ADAPT2
4 Pages
-
SLC ADAPT / 2 catalogue
16 Pages
-
Rechargeable AGM battery
4 Pages
-
EQUINOX2 S/SX
4 Pages
-
DC power S
4 Pages
-
DC power L
4 Pages
-
NS
2 Pages
-
EMi3
4 Pages
-
CV30-PV
4 Pages
-
SLC CUBE4
4 Pages
-
EQUINOX2 HT
4 Pages
-
RE3
4 Pages
-
SLC CUBE4 Catalogue
16 Pages
-
CONTROLVIT
32 Pages
-
EQUINOX2 HSX
4 Pages
-
SLC ADAPT
4 Pages
-
SLC TWIN PRO2 0-3K
4 Pages
-
SLC CUBE3+
4 Pages
-
VR EQX
4 Pages
-
CS IS
2 Pages
-
CV50
4 Pages
-
SPS ONE
4 Pages
-
SALICRU General Catalogue
204 Pages
-
SLC TWIN RT3 4-10 kVA
4 Pages
-
SLC TWIN RT3 1-3 KVA
4 Pages
-
CV30
4 Pages
-
CV10
4 Pages
-
ACV30-PV
4 Pages
-
Homes, offices & shops
4 Pages
-
Industry
4 Pages
-
Infrastructures and energy
4 Pages
-
Telecominications
4 Pages
-
Energy and renewables
4 Pages
-
SLC TWIN PRO3 4-10 kVA
4 Pages
-
SPS.ATS
2 Pages
-
SLC XPERT
4 Pages
-
IT Transformers
2 Pages
-
SLC X-TRA
4 Pages
-
ARC
2 Pages
-
SPS HOME
4 Pages
-
SPS ADVANCE RT2
4 Pages
-
SPS SOHO
4 Pages
-
SPS ADV R
4 Pages
-
SPS ADV T
4 Pages
-
SPS NET
2 Pages
-
SPS SAFE
2 Pages
-
CF CUBE3+
4 Pages
-
SPS PDU
2 Pages
-
SOFTWARE
2 Pages
-
BACS
4 Pages
-
SLC XPERT catalogue
12 Pages
-
SLC CUBE3+ Catalogue
8 Pages
-
SLC X-TRA Catalogue
12 Pages
Archived catalogs
-
ILUEST+ MT
4 Pages
-
IT M
4 Pages
-
EQUINOX S
4 Pages
-
EQUINOX TL
4 Pages
-
EQUINOX TM
4 Pages
-
ILUEST+ CR
4 Pages
-
SLC TWIN RT2 0-3kVA
4 Pages
-
SLC TWIN PRO2 4-20kVA
4 Pages
-
SLC ADAPT
2 Pages
-
SLC TWIN PRO
2 Pages
-
FAC P
2 Pages
-
OPTIMUS
2 Pages
-
SLC ADAPT
2 Pages
-
ILUEST+ Catalogue
12 Pages
-
RE brochure
2 Pages
-
EMi2 brochure
2 Pages
-
Brochure SLC CUBE3
2 Pages
-
Catalogue SLC-CUBE3
12 Pages