SLC TWIN PRO3 4-10 kVA-1

On-line double conversion IoT UPS from 4 to 10 kVA with PF=1 SLC TWIN PRO3 4-10 KVA: Robustness, energy efficiency and extended connectivity: the best combination to protect your productive environment Salicru’s SLC TWIN PRO3 series of uninterruptible power supplies (UPSs) is the successor to the prestigious SLC TWIN PRO2 family, offering improved functionality and representing a step forward in terms of technology. The range starts at 4 kVA and includes 5, 6, 8 and 10 kVA models. There are also specific B1 versions for extended backup, available in 6 and 10 kVA power ratings. The power factor of 1, increased energy efficiency and multiple operating modes give the SLC TWIN PRO3 a high level of added value in technical terms. It is the fourth incarnation of the SLC TWIN series and represents a consolidation of the on-line single-phase double conversion UPSs we have been offering to the market for over 12 years. This latest edition maintains the series’ characteristic robustness while adding cuttingedge technology in the form of complete connectivity that will meet the technological expectations of even the most demanding users. Its versatility in terms of communication deserves particular mention. The smart slot is joined by direct connections to the native Ethernet, USB and RS-232 ports or a Wi-Fi dongle. This broad spectrum of connectivity is complemented by the NIMBUS app and website access, which offer multiple options for monitoring and interacting with the connected devices, thereby enabling simultaneous viewing of all of the connected Salicru devices (even if they are from different series). Applications: Critical and sensitive loads that require close supervision Salicru’s SLC TWIN PRO3 series is the best option for ensuring continuity with constant and precise monitoring. Critical environments that maintain highly productive structures, such as ERP systems, Business Intelligence (BI), CRM solutions, networks, etc. need to be backed by the kind of energy security provided by the SLC TWIN PRO3 series, which also protects them against frequency and voltage variations and other types of disturbances that can affect the netwo

 Open the catalog to page 1
SLC TWIN PRO3 4-10 kVA-2

Performances ∙ On-line double conversion and DSP technology. ∙ Output power factor PF=1. ∙ Tower format with a reduced footprint to save space. ∙ Eco-mode operation for increased efficiency. ∙ Up to 3 devices can be connected in parallel (optional). ∙ Backup extensions available. ∙ Automatic detection of external battery modules via RJ-45. ∙ Frequency converter function (with and without batteries). ∙ Programmable automatic and manual battery test. ∙ Choice of 10 languages. ∙ Native Ethernet port for NIMBUS IoT, USB and RS-232 interfaces as standard on all models. ∙ Monitoring software for Windows,...

 Open the catalog to page 2
SLC TWIN PRO3 4-10 kVA-3

Range CODE Dimensions and weights for devices with standard backup. Please visit www.salicru.com for extended backup with additional EBM modules. Connections 1. Input/output connection terminals. 2. Earth cable connection. 3. Input circuit breaker. 4. Auxiliary IEC C19 output. 5. Auxiliary IEC C13 outputs. 6. Manual bypass. 7. Parallel port. 8. Digital E/S and emergency power-off (EPO). 9. USB interface. 10. Ethernet port for CLOUD. 11. HDMI port for NIMBUS dongle. 12. Battery module connection. 13. Smart slot for SNMP/AS400/RS-485-Modbus. 14. RS-232 interface. 15. Battery module communication...

 Open the catalog to page 3
SLC TWIN PRO3 4-10 kVA-4

REF. JJ156A01 CODE 401AB001431 ED. JANUARY 2023 - UNINTERRUPTIBLE POWER SUPPLY SYSTEMS (UPS) Technical specifications MODEL On-line double-conversion Tower Rated voltage Voltage range Rated frequency Frequency range Total harmonic distortion (THDi) Power factor Power factor Rated voltage Voltage accuracy Total harmonic distortion (THDv) ±1 % < 1% linear load / < 5% non-linear load Synchronised frequency Eco-mode performance Total performance in On-line mode Admissible overloads in battery mode Admissible overloads in bypass mode Admissible overloads in-line mode Parallel BATTERY Yes, up to 3...

 Open the catalog to page 4

All SALICRU catalogs and technical brochures

  1. EMi3

    4  Pages

  2. BM-R

    2  Pages

  3. SLC MANAGER

    2  Pages

  4. SLC CUBE3+

    4  Pages

  5. DC power L

    4  Pages

  6. DC power S

    4  Pages

  7. SLC ADAPT2

    4  Pages

  8. RE3

    4  Pages

  9. SPS HOME+

    4  Pages

  10. EQUINOX2 HT+

    4  Pages

  11. EQUINOX

    28  Pages

  12. EQUINOX2 HT

    4  Pages

  13. SLC CUBE4 R

    4  Pages

  14. SPS ONE

    4  Pages

  15. SPS SOHO

    4  Pages

  16. SPS ADV T

    4  Pages

  17. SPS NODE

    4  Pages

  18. SPS NET2

    2  Pages

  19. EQUINOX2 T

    4  Pages

  20. EQUINOX2 S/SX

    4  Pages

  21. NS

    2  Pages

  22. CV30-PV

    4  Pages

  23. SLC CUBE4

    4  Pages

  24. CONTROLVIT

    32  Pages

  25. EQUINOX2 HSX

    4  Pages

  26. SLC ADAPT

    4  Pages

  27. VR EQX

    4  Pages

  28. CS IS

    2  Pages

  29. CV50

    4  Pages

  30. Industry

    4  Pages

  31. SOFTWARE

    2  Pages

  32. CV30

    4  Pages

  33. CV10

    4  Pages

  34. ACV30-PV

    4  Pages

  35. SPS.ATS

    2  Pages

  36. SLC XPERT

    4  Pages

  37. SLC X-TRA

    4  Pages

  38. ARC

    2  Pages

  39. SPS SAFE

    2  Pages

  40. CF CUBE3+

    4  Pages

  41. SPS PDU

    2  Pages

  42. BACS

    4  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.