Catalog excerpts
Uninterruptible Power Supplies (UPS) with IoT from 7.5 to 80 kVA
Open the catalog to page 1Uninterruptible Power Supplies with IoT from 7.5 to 80 kVA The most advanced continuity protection on the market Salicru’s SLC CUBE4 Uninterruptible Power Supplies are the most cutting-edge security solution for all critical systems and sensitive loads. They have a Nimbus cloud connection that allows for equipment monitoring as standard, as well as options of remote management incident notification, equipment health monitoring and preventive maintenance. With three-level on-line technology and quad-core DSP control, they are three-phase input/output systems that offer a range of first-class...
Open the catalog to page 2USER FRIENDLY EXTENDED CONNECTIVITY 5” touchscreen. Intuitive UI using a common look and feel with other Salicru 3-phase UPS models Default Nimbus communication card. Remote diagnostics, remote maintenance, SNMP platform integration, MODBUS/TCP protocol, server shutdown and remote firmware update for the NIMBUS card. SMALL DIMENSIONS Optimized footprint, being one of the smallest in the market. Excelent power density throught all the power range. EASY ACCESS Frontal access to the replace the cooling fans(1) and batteries(2). Easy to replace battery pack blister(2). Low Mean Time To Repare...
Open the catalog to page 3Efficiency Three-level topology with DSP control VFI double conversion technology Three-level switching, which is based on switching the IGBTs in half-cycles (positive and negative), controlled by floating point DSP with exclusive cores for the rectifier and inverter, provides maximum performance in double conversion. Double conversion of the voltage between input and output (AC/DC – DC/AC) in accordance with VFI-SS-111 (EN-IEC 62040-3) operation, providing clean, stable and reliable voltage at output. Lowers cooling costs and increases energy efficiency by more than 96% from a 25% charge,...
Open the catalog to page 4Reliability Cutting-edge technology Modular design Advanced digital control techniques, developed in collaboration with leading European research centres and implemented in quad-core signal processors. Power modules with a repeating design, divided by phase and internally arranged in parallel in order to increase power. Thereby making it possible to apply the most advanced features. The design optimises manufacturing processes and reliability while reducing the time required for intervention in the event of an incident (MTTR – mean time to repair). QUAD CORE DSP CONTROL DSP DUAL CORE 1...
Open the catalog to page 5Operability Very compact design High availability One of the most compact solutions on the market, with a footprint of just 0.172 m2 up to 20 KVA, 0.345 m2 up to 40 kVA and 0.515 m2 up to 80 kVA. For standard backup, the batteries are always included in the same cabinet. The design and concept of the SLC CUBE4 series takes into account two factors that play an important role over the operational lifetime of the device: maximising MTBF (mean time between failures) and minimising MTTR (mean time to repair). By optimising these two variables, the need to call out technical services is reduced...
Open the catalog to page 6IoT solution Nimbus Service in the cloud Standard interfaces The SLC CUBE4 series of UPS systems incorporate a Nimbus communication card as standard. Connecting this card via Ethernet opens up a world of communication possibilities, ranging from remote diagnostics and maintenance to integration with SNMP platforms, MODBUS/TCP protocol, ordered shutdown of servers and/or remote firmware updates for the Nimbus card. The communication channels that have been incorporated into the device are many and varied, and include USB, RS-232 and RS-485 (1) interfaces, 1 x slot with Nimbus/SNMP-Ethernet...
Open the catalog to page 7Battery-care Batt-watch Compatible with all types of battery The batteries, which provide the backup time in the event of a power outage, are one of the most sensitive components in a UPS solution. Consequently, they require special care in order to maximise their service life and keep them in optimum working condition. The techniques that are used to treat them with as much care as possible include float voltage temperature compensation, manual and automatic battery testing, isolating the batteries from voltage ripples and intermittent charging. Allows for the charging of different battery...
Open the catalog to page 8Range MODEL RACK Naming, dimensions and weights for units with 3 x 400 V input voltage, 3 x 400 V input voltage and standar back up time Lateral protuberance, from each side plane of the UPS (elements to fix and handling the UPS itself): 23mm / side. This distance is not included in the “width” total dimension Frontal protuberance, from the fixing plane of the ears to the rack cabinet: 46mm. This distance is not included in the “Depth” total dimension Battery connector EMBP signal port Thermal protection switch for IEC C13 IEC C13 output IEC C19 output Thermal protection switch for IEC C19...
Open the catalog to page 10Range MODEL TOWER Nomenclature, dimensions and weights for devices with input voltage of 3 x 400 V, output voltage of 3 x 400 V and standard backup. These codes belong to UPS with internal batteries. Please, enquire for additional battery modules. 1. Nimbus cloud card 2. Free communications slot 3. Parallel port 4. USB interface 5. RS-232/(485) interface 6. Digital Input 7. Relay indicators 8. Input circuit breaker/disconnector 9. Output circuit breaker 10. Manual bypass circuit breaker 11. Bypass circuit breaker 12. Battery disconnector 13. Connection board cover 14. Input, output, bypass...
Open the catalog to page 11Technical specifications SLC CUBE4 / SLC CUBE4 R On-line, double conversion, HF, DSP control Rated voltage Voltage range Rated frequency Frequency range Total harmonic distortion (THDi) Power factor Rectifier topology 7,5 ÷ 20 kVA: <4% / 30 ÷ 80 kVA: <3% 1 from 10% load Three-phase IGBT full wave, soft start, PFC, transformerless Power factor Rated voltage Dynamic accuracy Static accuracy Frequency Overall performance in On-line Mode Performance in Smart Eco Mode Permissible overload Crest factor MANUAL BYPASS Type STATIC BYPASS Activation type and criteria Transfer time in Smart mode Eco...
Open the catalog to page 12All SALICRU catalogs and technical brochures
-
Rechargeable AGM battery
4 Pages
-
SLC ADAPT
4 Pages
-
SLC ADAPT2
4 Pages
-
SLC ADAPT / 2 catalogue
16 Pages
-
SLC TWIN PRO2 0-3K
4 Pages
-
SLC CUBE3+
4 Pages
-
CONTROLVIT
32 Pages
-
EQUINOX
20 Pages
-
VR EQX
4 Pages
-
EQUINOX2 HSX
4 Pages
-
CS IS
2 Pages
-
RE3
4 Pages
-
EMi3
4 Pages
-
EQUINOX2 HT
4 Pages
-
CV50
4 Pages
-
SLC CUBE4
4 Pages
-
SPS ONE
4 Pages
-
SALICRU General Catalogue
204 Pages
-
SLC TWIN RT3 4-10 kVA
4 Pages
-
SLC TWIN RT3 1-3 KVA
4 Pages
-
CV30-PV
4 Pages
-
EQUINOX2 T
4 Pages
-
CV30
4 Pages
-
CV10
4 Pages
-
ACV30-PV
4 Pages
-
Homes, offices & shops
4 Pages
-
Industry
4 Pages
-
Infrastructures and energy
4 Pages
-
Telecominications
4 Pages
-
Energy and renewables
4 Pages
-
SLC TWIN PRO3 4-10 kVA
4 Pages
-
SPS.ATS
2 Pages
-
SLC TWIN RT2 LION
4 Pages
-
SLC XPERT
4 Pages
-
IT Transformers
2 Pages
-
SLC X-TRA
4 Pages
-
ARC
2 Pages
-
NS
2 Pages
-
DC power L
4 Pages
-
SPS HOME
4 Pages
-
SPS ADVANCE RT2
4 Pages
-
DC power S
4 Pages
-
SPS SOHO
4 Pages
-
SPS ADV R
4 Pages
-
SPS ADV T
4 Pages
-
SPS NET
2 Pages
-
SPS SAFE
2 Pages
-
CF CUBE3+
4 Pages
-
SPS PDU
2 Pages
-
EQUINOX2 S/SX
4 Pages
-
SOFTWARE
2 Pages
-
BACS
4 Pages
-
SLC XPERT catalogue
12 Pages
-
SLC CUBE3+ Catalogue
8 Pages
-
SLC X-TRA Catalogue
12 Pages
Archived catalogs
-
ILUEST+ MT
4 Pages
-
IT M
4 Pages
-
EQUINOX S
4 Pages
-
EQUINOX TL
4 Pages
-
EQUINOX TM
4 Pages
-
ILUEST+ CR
4 Pages
-
SLC TWIN RT2 0-3kVA
4 Pages
-
SLC TWIN PRO2 4-20kVA
4 Pages
-
SLC ADAPT
2 Pages
-
SLC TWIN PRO
2 Pages
-
FAC P
2 Pages
-
OPTIMUS
2 Pages
-
SLC ADAPT
2 Pages
-
ILUEST+ Catalogue
12 Pages
-
RE brochure
2 Pages
-
EMi2 brochure
2 Pages
-
Brochure SLC CUBE3
2 Pages
-
Catalogue SLC-CUBE3
12 Pages