Uninterruptible Power Supplies (UPS) from 7.5 to 80 kVA
Open the catalog to page 1Uninterruptible Power Supplies from 7.5 to 80 kVA The most advanced continuity protection on the market Salicru’s SLC CUBE4 Uninterruptible Power Supplies are the most cutting-edge security solution for all critical systems and sensitive loads. They have an optional Nimbus cloud connection that allows for equipment monitoring, as well as options of remote management incident notification, equipment health monitoring and preventive maintenance. With three-level on-line technology and quad-core DSP control, they are three-phase input/output systems that offer a range of first-class features, including...
Open the catalog to page 2USER FRIENDLY EXTENDED CONNECTIVITY 5” touchscreen. Intuitive UI using a common look and feel with other Salicru 3-phase UPS models Remote diagnostics, remote maintenance, SNMP platform integration, MODBUS/TCP protocol, server shutdown and remote firmware update, via the Nimbus communications card (optional). SMALL DIMENSIONS Optimized footprint, being one of the smallest in the market. Excelent power density throught all the power range. EASY ACCESS Frontal access to the replace the cooling fans(1) and batteries(2). Easy to replace battery pack blister(2). Low Mean Time To Repare (MTTR). (1)...
Open the catalog to page 3Efficiency Three-level topology with DSP control VFI double conversion technology Three-level switching, which is based on switching the IGBTs in half-cycles (positive and negative), controlled by floating point DSP with exclusive cores for the rectifier and inverter, provides maximum performance in double conversion. Double conversion of the voltage between input and output (AC/DC – DC/AC) in accordance with VFI-SS-111 (EN-IEC 62040-3) operation, providing clean, stable and reliable voltage at output. Lowers cooling costs and increases energy efficiency by more than 96% from a 25% charge, thereby...
Open the catalog to page 4Reliability Cutting-edge technology Modular design Advanced digital control techniques, developed in collaboration with leading European research centres and implemented in quad-core signal processors. Power modules with a repeating design, divided by phase and internally arranged in parallel in order to increase power. Thereby making it possible to apply the most advanced features. The design optimises manufacturing processes and reliability while reducing the time required for intervention in the event of an incident (MTTR – mean time to repair). QUAD CORE DSP CONTROL DSP DUAL CORE 1 Redundant...
Open the catalog to page 5Operability Very compact design High availability One of the most compact solutions on the market, with a footprint of just 0.172 m2 up to 20 KVA, 0.345 m2 up to 40 kVA and 0.515 m2 up to 80 kVA. For standard backup, the batteries are always included in the same cabinet. The design and concept of the SLC CUBE4 series takes into account two factors that play an important role over the operational lifetime of the device: maximising MTBF (mean time between failures) and minimising MTTR (mean time to repair). By optimising these two variables, the need to call out technical services is reduced to...
Open the catalog to page 6IoT solution Nimbus Service in the cloud Standard interfaces The SLC CUBE4 series of UPS systems incorporates a Nimbus communication card as an optional. Connecting this card via Ethernet opens up a world of communication possibilities, ranging from remote diagnostics and maintenance to integration with SNMP platforms, MODBUS/TCP protocol, ordered shutdown of servers and/or remote firmware updates for the Nimbus card. The communication channels that have been incorporated into the device are many and varied, and include USB, RS-232 and RS-485 (1) interfaces, 2 x free smart slot (2), digital inputs,...
Open the catalog to page 7Battery-care Batt-watch Compatible with all types of battery The batteries, which provide the backup time in the event of a power outage, are one of the most sensitive components in a UPS solution. Consequently, they require special care in order to maximise their service life and keep them in optimum working condition. The techniques that are used to treat them with as much care as possible include float voltage temperature compensation, manual and automatic battery testing, isolating the batteries from voltage ripples and intermittent charging. Allows for the charging of different battery types:...
Open the catalog to page 8Range CODE Nomenclature, dimensions and weights for devices with input voltage of 3 x 400 V, output voltage of 3 x 400 V and standard backup. Protrusion from the side surfaces of the main body of the UPS (elements for mounting and handling the device): 23 mm per side. This distance is not included in the dimensions quoted for “Width”. Front protrusion from the mounting surface to the rack cabinet: 46 mm. This distance is not included in the dimensions quoted for “Depth”. Battery terminals. Signals port BPME. Sockets thermal protection IEC C13. Output sockets IEC C13. Output sockets IEC C19. Sockets...
Open the catalog to page 10Technical specifications MODEL TECHNOLOGY Rated voltage Voltage range Rated frequency Frequency range Total harmonic distortion (THDi) Power factor Rectifier topology OUTPUT Rated voltage Dynamic accuracy Static accuracy Synchronised frequency Free running frequency Performance in Smart Eco-mode Crest factor MANUAL BYPASS STATIC BYPASS Type and activation criteria Transfer times in Smart Eco-mode (ms) Transfer to bypass Retransfer Battery type Charging voltage regulation Ports 3:1 Uninterrupted Solid state <10 ms Immediate, for overloads exceeding 150% Automatic, after alarm deactivation Pb-Ca,...
Open the catalog to page 11Range CODE Nomenclature, dimensions and weights for devices with input voltage of 3 x 400 V, output voltage of 3 x 400 V and standard backup. This code corresponds olny to the UPS module. Consult code for battery module. Intelligent slot for nimbus cloud (optional) Free communications slot Parallel port USB interface RS-232/(485) interface Digital Inputs Relay indicators Input circuit breaker/disconnector Output circuit breaker Manual bypass circuit breaker Bypass circuit breaker Battery disconnector Connections cover Inlet, outlet, bypas
Open the catalog to page 124 Pages
2 Pages
216 Pages
2 Pages
4 Pages
4 Pages
4 Pages
4 Pages
4 Pages
4 Pages
4 Pages
4 Pages
4 Pages
28 Pages
4 Pages
4 Pages
4 Pages
4 Pages
4 Pages
4 Pages
4 Pages
2 Pages
4 Pages
4 Pages
16 Pages
4 Pages
2 Pages
4 Pages
4 Pages
2 Pages
4 Pages
4 Pages
32 Pages
4 Pages
4 Pages
4 Pages
4 Pages
2 Pages
4 Pages
4 Pages
4 Pages
2 Pages
4 Pages
4 Pages
4 Pages
4 Pages
4 Pages
4 Pages
4 Pages
2 Pages
4 Pages
4 Pages
4 Pages
2 Pages
2 Pages
4 Pages
2 Pages
4 Pages
12 Pages
8 Pages
12 Pages
4 Pages
4 Pages
2 Pages
12 Pages
4 Pages
4 Pages
4 Pages
4 Pages
4 Pages
4 Pages
4 Pages
4 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
12 Pages