video corpo

SLC ADAPT / 2 catalogue
16Pages

{{requestButtons}}

Catalog excerpts

SLC ADAPT / 2 catalogue - 1

Modular Uninterruptible Power Supply (UPS) from 10 to 1,500 kVA

Open the catalog to page 1
SLC ADAPT / 2 catalogue - 2

Modular Uninterruptible Power Supply (UPS) from 10 to 1,500 kVA Maximum availability and improved energy efficiency Salicru’s SLC ADAPT2 series is a range of modular On-line doubleconversion (VFI) UPS systems that provide maximum electrical protection to connected loads and, at the same time, flexibility and adaptability to future growth needs of the facility, yielding substantial financial and energy savings. The solution consists of power modules ranging from 10 to 50 kVA located in cabinets of up to 12 modules which, in turn, can form solutions of up to 30 modules, providing maximum...

Open the catalog to page 2
SLC ADAPT / 2 catalogue - 3

Modularity Wide range of power modules available Modules available with power ratings of 10, 15, 25 and 50 kVA, adaptable to any initial power demand or facing a potenital future growth of it. Pay as you grow’ planning. Vertical scalability up to 600 kVA per cabinet Wide range of configurations in cabinets of 2, 3,4 or 6 modules or cabinets of 2,3,4,6, 8, 10 or 12 modules, enabling configurations from 1x10 kVA (10 kVA) to 12x50 kVA (600 kVA) in a single cabinet. The widest range of configurations for medium-sized power solutions. Hot-swap and hot-plug connection Hot-swap and hot-plug...

Open the catalog to page 3
SLC ADAPT / 2 catalogue - 4

Availability Configurable redundancy N+1, N+2,…, Configurable level of redundancy according to the needs of each facility, reaching levels of availability of 99.9999%. Equipment is permanently monitored through its standard integration in Salicru’s Nimbus-cloud. Provides the facility with greater security, while it is a much more competitive solution than the traditional paralleling of UPSs. It allows a continuous analysis of the level of protection provided. Load supported by each module Predictive maintenance The status of the key components can be viewed through the LCD display....

Open the catalog to page 4
SLC ADAPT / 2 catalogue - 5

Reliability Totally independent modules Each module incorporates a filter, control, rectifier, battery charger, inverter system and hybrid bypass. Ease of load distribution, battery charging and maintenance operations Input Output to critical loads POWER MODULE Redundant fans Dedicated system of redundant fans with separate air flow circuits for each power module’s rectifier and inverter blocks. VFI double-conversion technology Double conversion between input and output, AC/DC + DC/AC, providing a clean, stable and reliable voltage at the output. Redundant security in one of the most...

Open the catalog to page 5
SLC ADAPT / 2 catalogue - 6

Flexibility Modules of 10 to 50 kVA and cabinets with 2, 3, 4, 6, 8, 10 or 12 power modules More than 70 possible combinations for the different cabinets and modules available. And up to 1,000 possible combinations for cabinet systems in parallel. Maximum adaptability to the needs of each facility and its future growth. Backup adaptable to growth needs Installation of batteries inside the equipment(1) itself or held in separate cabinets in the same equipment, with the possibility of expansion according to the evolution of the facility’s power demand. Provides adaptability to the varable...

Open the catalog to page 6
SLC ADAPT / 2 catalogue - 7

Resilience Totally decentralised control High power factor for any kind of load Each power module has its own fully independent control without master/slave structure to achieve a completely balanced distribution of loads. For SLC Adapt 2 models, the Output Power Factor is the unit (PF = 1). Wide power factor range, even in the event of sudden and rapid changes. Ensures continued protection of loads with immediate readjustment of their distribution, always searching the maximum efficiency point. Ability to supply loads without degrading power or affecting the protected processes. CAPACITIVE...

Open the catalog to page 7
SLC ADAPT / 2 catalogue - 8

TCO High efficiency in double conversion Very low input current harmonic distortion (THDi) 3-level PWM power modules with integrated IGBT packs. No need to oversize the capacity of the power generator, transformers or power cables. Reduces cooling costs and improves energy efficiency, bringing down total operating expenses (OpEx). Reduced space requirement Brings down total capital expenditure (CapEx). On-line mode in Smart-efficiency Up to 300 kVA kept inside a 0.66 m2 footprint, for greater power density. Greater power in the same reduced space, thereby bringing down total capital...

Open the catalog to page 8
SLC ADAPT / 2 catalogue - 9

Applications Data centres: Ensuring the operability of environments and preventing losses caused by power outages, whether in modular or virtualised data centres for hosting, housing, computer centres, supercomputers, etc. Health: Electromedical equipment for analysis, laboratories and vital instruments for ICUs, as well as administration systems, security, medical records, etc. Financial services: Maintaining the online functionality of financial transactions in centralised payment authorisation systems, continued listing, intercommunication between banking networks, etc....

Open the catalog to page 9
SLC ADAPT / 2 catalogue - 10

Options - Extended backup time: Additional battery cabinets for facilities that require long backup time. - Nimbus monitoring and management software: Sending of warning messages (broadcast, email, SMS), scheduled shutdowns, etc. - Systems in cabinets: 10 or 15 kW subracks with 2, 3, 4 or 6 modules can be installed in 1100/1600/2000 mm-high cabinets, with or without batteries included. Batteries can also be installed in additional cabinets. - Shutdown software: For heterogeneous network systems with different operating systems. - Nimbus remote maintenance with/without GPRS modem: Webbased...

Open the catalog to page 10
SLC ADAPT / 2 catalogue - 11

Options - Frequency converter: For 50 to 60 Hz or 60 to 50 Hz conversion - Separate bypass line: For facilities with dual power supply, enabling the separation of the inverter and the bypass line power supplies. - External manual bypass panel: Enables maintenance operations with the UPS isolated. - Protection panel: Electrical panel equipped with input and output protection. - Single-phase output: With single-phase or three-phase input for installations of up to 1.500 kVA. - LBS (Load Bus Synchronisation): Optional module to keep synchronized the outputs of two single UPS’s two, even if...

Open the catalog to page 11

All SALICRU catalogs and technical brochures

  1. SPS NODE

    4 Pages

  2. SPS NET2

    2 Pages

  3. EQUINOX2 T

    4 Pages

  4. EQUINOX

    20 Pages

  5. SLC ADAPT2

    4 Pages

  6. DC power S

    4 Pages

  7. DC power L

    4 Pages

  8. NS

    2 Pages

  9. EMi3

    4 Pages

  10. CV30-PV

    4 Pages

  11. SLC CUBE4

    4 Pages

  12. EQUINOX2 HT

    4 Pages

  13. RE3

    4 Pages

  14. CONTROLVIT

    32 Pages

  15. EQUINOX2 HSX

    4 Pages

  16. SLC ADAPT

    4 Pages

  17. SLC CUBE3+

    4 Pages

  18. VR EQX

    4 Pages

  19. CS IS

    2 Pages

  20. CV50

    4 Pages

  21. SPS ONE

    4 Pages

  22. CV30

    4 Pages

  23. CV10

    4 Pages

  24. ACV30-PV

    4 Pages

  25. Industry

    4 Pages

  26. SPS.ATS

    2 Pages

  27. SLC XPERT

    4 Pages

  28. SLC X-TRA

    4 Pages

  29. ARC

    2 Pages

  30. SPS HOME

    4 Pages

  31. SPS SOHO

    4 Pages

  32. SPS ADV R

    4 Pages

  33. SPS ADV T

    4 Pages

  34. SPS NET

    2 Pages

  35. SPS SAFE

    2 Pages

  36. CF CUBE3+

    4 Pages

  37. SPS PDU

    2 Pages

  38. SOFTWARE

    2 Pages

  39. BACS

    4 Pages

Archived catalogs

  1. ILUEST+ MT

    4 Pages

  2. IT M

    4 Pages

  3. EQUINOX S

    4 Pages

  4. EQUINOX TL

    4 Pages

  5. EQUINOX TM

    4 Pages

  6. ILUEST+ CR

    4 Pages

  7. SLC ADAPT

    2 Pages

  8. SLC TWIN PRO

    2 Pages

  9. FAC P

    2 Pages

  10. OPTIMUS

    2 Pages

  11. SLC ADAPT

    2 Pages

  12. RE brochure

    2 Pages