Three-phase hybrid solar inverters from 15 to 50 kW EQUINOX2 HT+: Maximize power with three-phase renewable energy The EQUINOX2 HT+ series of three-phase hybrid solar inverters improves the features and increases the power of the three-phase HT range, for application in installations with 3 x 380 V / 3 x 400 V. As such, we can continue to speak of maximum versatility. By increasing the power of the hybrid inverter range, the EQUINOX2 HT+ can be adapted to suit a wider range of scenarios and possibilities in more industrial settings. The power rating of the EQUINOX2 HT+ goes up to 50 kW, while the inverters stand out for their high level of efficiency (98.8%). They boast batteries with a charge and discharge capacity of up to 100 A, an input current capacity of up to 30 A per string, and can work with unbalanced loads and phases, reaching levels of up to 110%. Like the EQUINOX2 HT range, they have a full backup function built into the device itself. The mode for operation without batteries ensures that photovoltaic energy is still available even when the batteries are in poor condition, disconnected for replacement or even if the user decides to acquire them at a future date and initially operates the system without storage. Although this function is usually temporary, it helps to enhance the already comprehensive availability of the installation. It should also be noted that, for installations with very unbalanced phases, Salicru’s hybrid range is an excellent solution for ensuring correct use of solar power. The backup function for critical loads is also worth highlighting. Thanks to technological advances, the EQUINOX2 HT+ boasts a transfer speed of just 20 ms, thereby ensuring the continued operation of connected devices in the event of an unexpected power outage and without requiring any manual intervention. Applications: Self-consumption up to 50 kW The EQUINOX2 HT+ range offers a high degree of independence from the electricity grid, with a three-phase installation. It is the ideal solution for commercial facilities with low- and medium-powered machinery, such as garages, production centres, retail food outlets, the hospitality industry, etc. The devices also allow production processes to be scaled upwards without the need to increase the contracted power, thereby offering users direct savings on their monthly energy bills.
Open the catalog to page 1• Input current adapted for high-performance panels. • 4 MPPT trackers with dual 30 A input. • Very low start-up voltage of 200 VDC and battery charging capacity with low solar radiation. • Admits DC input power 50% above the nominal level. • Battery transfer time of less than 20 ms. • Option of delivering 10% more power in addition to the nominal. • Fast charging/discharging of up to 100 A. Fast battery charging (1 hour). • Backup of up to 110% of nominal power, in battery mode. • Wide battery voltage range: 135-750 V. • Capacity to work with 110% unbalanced loads. • 120% maximum output overload...
Open the catalog to page 2Range MODEL MAXIMUM MAXIMUM DC RATED POWER APPARENT INPUT POWER (kW) OUTPUT POWER (kW) OUTPUT CURRENT Batteries selection BASE CODE BATTERY CODE Please enquire for longer backup (only for 4 MPPT models) DC disconnectors MC4 DC connectors Battery connectors COM1 port (USB Wi-Fi connection) COM2 port (BMS connection) COM3 port (auxiliary connection) AC output terminal Backup output terminal Connector for auxiliary generator only available for the EQX2 25004÷50004-HT+ models (unde
Open the catalog to page 3REF JJ189A01 CODE 401AB001545 ED FEBRUARY 2024 - SOLAR INVERTERS Technical specifications MODEL MPPT voltage range with battery MPPT voltage range (VDC) Input maximum current per tracker (A) Power factor Network voltage Voltage ranges Max. total harmonic distortion (THD) Maximum performance 195.5 t 253 V (F-N); adjustable depending on the country <3 % 50 Hz / 60 Hz; margins adjustable depending on the country 97,5% 98,3% OUTPUT Back-up Transfer time (ms) PROTECTION Input DC disconnector Bipolar. Load break DC reverse polarity, battery input connection reversal, insulation resistance, DC overvoltage,...
Open the catalog to page 44 Pages
2 Pages
216 Pages
2 Pages
4 Pages
4 Pages
4 Pages
4 Pages
4 Pages
4 Pages
4 Pages
4 Pages
28 Pages
4 Pages
4 Pages
4 Pages
4 Pages
4 Pages
4 Pages
4 Pages
2 Pages
4 Pages
4 Pages
16 Pages
4 Pages
2 Pages
4 Pages
4 Pages
2 Pages
4 Pages
4 Pages
16 Pages
32 Pages
4 Pages
4 Pages
4 Pages
4 Pages
2 Pages
4 Pages
4 Pages
4 Pages
2 Pages
4 Pages
4 Pages
4 Pages
4 Pages
4 Pages
4 Pages
4 Pages
2 Pages
4 Pages
4 Pages
4 Pages
2 Pages
2 Pages
4 Pages
2 Pages
4 Pages
12 Pages
8 Pages
12 Pages
4 Pages
4 Pages
2 Pages
12 Pages
4 Pages
4 Pages
4 Pages
4 Pages
4 Pages
4 Pages
4 Pages
4 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
12 Pages