EQUINOX2 HSX - 1

Single-phase hybrid solar inverters from 3 to 8 kW EQUINOX2 HSX: Maximum energy availability The EQUINOX2 HSX range of single-phase hybrid solar inverters makes maximum use of energy generated for self-consumption. On the one hand, like the On-Grid models of the EQUINOX2 S/SX/T series, high-energy efficiency continues to be an important factor for EQUINOX2 HSX. However, the extreme versatility is an even more crucial factor. The EQUINOX2 HSX devices have up to 6 operating modes. Peak Shaving mode, surplus energy graded management: load/batteries/ grid, time-slot discrimination mode, automatic backup mode, isolated mode and operating mode without batteries. In the characteristic back-up mode, the system functions as a UPS capable of supplying 100% of the nominal power of the inverter to the loads, and all with an automatic transfer less than 10 ms in case of a mains supply outage. In this regard, our EQUINOX2 BATT storage system allows scaled growth according to autonomy time and the loads that you want to supply with power. The wide voltage range accepted by the EQUINOX2 HSX and EQUINOX2 HT hybrid inverters makes it possible to connect batteries in series of up to 10 stackable modules, which provide 25.6kWh at a voltage of 512V. The operating mode without batteries ensures that photovoltaic energy is still available even when the batteries are in poor condition, disconnected for replacement or even if the user decides to acquire them at a future date and initially operates the system without storage. Applications: Domestic self-consumption up to 8kW with high sustainability Whenever, whether in a domestic or small business environment, you want to ensure a high degree of independence from the grid or when consumption is concentrated in times outside those of maximum radiation, and the income from the sale of energy to the grid does not sufficiently compensate the expenditure item for energy from the conventional grid. EQUINOX2 BATT perfectly completes the hybrid solution.

Open the catalog to page 1
EQUINOX2 HSX - 2

Performances ∙ High conversion efficiency and input current adapted to highperformance panels. ∙ Two 15 A MPPT trackers without current penalty by the battery connection.(1) ∙ Very low start-up voltage of 80 Vdc and battery charging capacity with low solar radiation. ∙ Admits +60% of input power in DC, above the nominal voltage. ∙ Possibility of delivering 10% more power in addition to the nominal. ∙ Fast charging/discharging of up to 30 A. Fast battery charging (1 hour). ∙ Back-up of up to 100% of nominal power, in battery mode. ∙ Made from aluminium and coated with epoxy paint to...

Open the catalog to page 2
EQUINOX2 HSX - 3

Range MODEL MAXIMUM MAXIMUM DC RATED POWER APPARENT INPUT POWER (kW) OUTPUT POWER (kW) OUTPUT CURRENT Batteries selection WEIGHT RATED RATED VOLTAGE (V) CAPACITY (kWh) BASE CODE BATTERY CODE DIMENSIONS (D x W x H mm) Positive photovoltaic input terminals Negative photovoltaic input terminals Main communication port (communication module connection). Auxiliary communication port (optional). AC / mains terminal. DC disconnector. Output connection for critical loads. Connection port for current metering. Communication port with batteries. Positive battery connection terminal. Negative battery...

Open the catalog to page 3
EQUINOX2 HSX - 4

REF. JJ138A01 CODE 401AB001372 ED. OCTOBER 2023 - SOLAR INVERTERS Technical specifications INPUT DC EQX2 3001-HSX Starting voltage (V) Max. short-circuit current - Isc PV (A) Input maximum current per tracker (A) Power factor Network voltage Voltage ranges Max. total harmonic distortion (THD) Frequency MPPT voltage range (VDC) OUTPUT Inputs per MPPT Inputs per MPPT Maximum performance Battery type Voltage range Maximum charge/discharge current 3 LED states, LED bar for battery level, OLED display Inverse polarity DC, Residual Current, DC disconnector, Over-voltage, Over-temperature,...

Open the catalog to page 4

All SALICRU catalogs and technical brochures

  1. SPS NODE

    4 Pages

  2. SPS NET2

    2 Pages

  3. EQUINOX2 T

    4 Pages

  4. EQUINOX

    20 Pages

  5. SLC ADAPT2

    4 Pages

  6. DC power S

    4 Pages

  7. DC power L

    4 Pages

  8. NS

    2 Pages

  9. EMi3

    4 Pages

  10. CV30-PV

    4 Pages

  11. SLC CUBE4

    4 Pages

  12. EQUINOX2 HT

    4 Pages

  13. RE3

    4 Pages

  14. CONTROLVIT

    32 Pages

  15. SLC ADAPT

    4 Pages

  16. SLC CUBE3+

    4 Pages

  17. VR EQX

    4 Pages

  18. CS IS

    2 Pages

  19. CV50

    4 Pages

  20. SPS ONE

    4 Pages

  21. CV30

    4 Pages

  22. CV10

    4 Pages

  23. ACV30-PV

    4 Pages

  24. Industry

    4 Pages

  25. SPS.ATS

    2 Pages

  26. SLC XPERT

    4 Pages

  27. SLC X-TRA

    4 Pages

  28. ARC

    2 Pages

  29. SPS HOME

    4 Pages

  30. SPS SOHO

    4 Pages

  31. SPS ADV R

    4 Pages

  32. SPS ADV T

    4 Pages

  33. SPS NET

    2 Pages

  34. SPS SAFE

    2 Pages

  35. CF CUBE3+

    4 Pages

  36. SPS PDU

    2 Pages

  37. SOFTWARE

    2 Pages

  38. BACS

    4 Pages

Archived catalogs

  1. ILUEST+ MT

    4 Pages

  2. IT M

    4 Pages

  3. EQUINOX S

    4 Pages

  4. EQUINOX TL

    4 Pages

  5. EQUINOX TM

    4 Pages

  6. ILUEST+ CR

    4 Pages

  7. SLC ADAPT

    2 Pages

  8. SLC TWIN PRO

    2 Pages

  9. FAC P

    2 Pages

  10. OPTIMUS

    2 Pages

  11. SLC ADAPT

    2 Pages

  12. RE brochure

    2 Pages