video corpo

EQUINOX
20Pages

{{requestButtons}}

Catalog excerpts

EQUINOX - 1

On-grid and hybrid solar inverters from 2 to 100 kW

Open the catalog to page 1
EQUINOX - 2

Solar inverters from 2 to 100 kW Top-quality renewable energy generation SALICRU’s new EQUINOX2 series brings a wide range of quality solar inverters with high-level performance specifications to the market. The EQUINOX2 family is available in 4 different versions: EQUINOX2 S/SX a single-phase on-grid inverter with a range of 2 to 10 kW. EQUINOX2 T, a three-phase on-grid inverter with a power range of 4 to 100 kW. EQUINOX2 HSX a single-phase hybrid inverter offering a range of 3 to 8 kW and unrivalled versatility thanks to its 6 operating modes, complemented by an EQUINOX 2 BATT. EQUINOX2...

Open the catalog to page 2
EQUINOX - 3

Features EXCEPTIONAL FINISHES THERMAL OPTIMISATION Simple lines and neutral colours make the EQUINOX2 an elegant and discreet product that blends seamlessly into any environment. The OLED matrix display offers comprehensive information at all times. Aluminium body and front cover, painted with high resistance powder coating. IP65 protection rating. The main body of the EQUINOX2 is a die-cast aluminium monoblock with a moulded heat sink to facilitate maximum thermal dissipation. The internal layout of the elements optimises heat distribution. The low levels of thermal stress placed on the...

Open the catalog to page 3
EQUINOX - 4

Complete solution Interior or exterior installation Like SALICRU’s previous inverter ranges, the EQUINOX2 inverters have been designed to provide a complete solution that comes with everything you need to integrate the inverter into your setup (with a series of optional features to extend the device’s capabilities even further). The robust finish and waterproof design of the EQUINOX2, which is manufactured in die-cast aluminium and coated with epoxy paint, allow for both interior and exterior installation (sheltered from direct sunlight and protected from the rain) without fear of damage...

Open the catalog to page 4
EQUINOX - 5

High-quality components All the operating parameters of EQUINOX2 devices can be monitored 24 hours a day (see available options) through our EQUINOX APP for iOS and Android and the WEB portal designed by our Connected Software department. Following the philosophy applied to all our devices, SALICRU manufactures inverters with high-quality components produced by leading brands, thus ensuring continuity of supply, reliable operation and satisfactory service life compliance. The end customer can also authorise the installer to visualise the setup’s behaviour, giving them access to the...

Open the catalog to page 5
EQUINOX - 6

General technical specifications EQUINOX2 RANGE PROTECTION Inverse polarity DC, Residual Current, DC disconnector, Over-voltage, Over-temperature, Differential, Islanding operation, AC short-circuit, Over-voltage AC Over-voltage protection category GENERAL Contamination level Self-consumption (at night) Operating temperature Relative humidity Maxium operating altitude Maximum power Degree of protection Isolation DC terminal type Installation Topology COMMUNICATION Ports Certificate Safety / EMC Energy efficiency Environmental tests Operation / Protection Quality and environmental management...

Open the catalog to page 6
EQUINOX - 7

Range On-Grid single-phase MODEL On-Grid three-phase MODEL Hybrid single-phase MODEL Hybrid three-phase MODEL

Open the catalog to page 7
EQUINOX - 8

Maximum DC input voltage (Vdc) Working-out rank (Vdc) Inputs per MPPT Max. short-circuit current per MPPT Input maximum current per tracker (A) OUTPUT Power factor Network voltage Voltage ranges Total harmonic distortion (THDi) Maximum performance INDICATIONS GENERAL MPPT performance Type Information subject to change without notice. 99,9% 2 LED states, OLED display Natural convection (no fans)(3) Acoustic noise at 1 metre (1) For PV inverters with more than 1 string per MPPT, please enquire about potential current restrictions (2) For 2 x 230 V two-phase voltages, ask (3) For EQX2 10002-SX...

Open the catalog to page 8
EQUINOX - 9

MODEL Maximum DC input voltage (Vdc) Working-out rank (Vdc) Inputs per MPPT Max. short-circuit current per MPPT Input maximum current per tracker (A) Power factor Network voltage Voltage ranges Total harmonic distortion (THDi) Information subject to change without notice. Maximum performance MPPT performance 2 LED de estado, display OLED Acoustic noise at 1 metre (1) For PV inverters with more than 1 string per MPPT, please enquire about potential current restrictions (2) For three-phase voltages without a neutral (triangle), ask (3) For models from EQX2 17002-T (inclusive) Smart fan...

Open the catalog to page 9
EQUINOX - 10

Technical specifications EQUINOX2 HSX MODEL Maximum DC input voltage (Vdc) Max. short-circuit current per MPPT Input maximum current per tracker (A) Power factor Network voltage Voltage ranges Total harmonic distortion (THDi) Maximum performance INDICATIONS 97,6% 3 LED states, LED bar for battery level, OLED display Natural convection (no fans) Acoustic noise at 1 metre Positive photovoltaic input terminals. Negative photovoltaic input terminals. Main communication port (communication module connection). Auxiliary communication port (optional). AC / mains terminal. DC switch. Output...

Open the catalog to page 10
EQUINOX - 11

Technical specifications EQUINOX2 HT INPUT Maximum DC input voltage (Vdc) Working-out rank (Vdc) Max. short-circuit current per MPPT Starting voltage (Vdc) Input maximum current per tracker (A) OUPUT Power factor Network voltage Voltage ranges Total harmonic distortion (THDi) Maximum performance 3 LED states , LED bar for battery level, OLED display Natural convection (no fans) Acoustic noise at 1 metre Information subject to change without notice (1) For three-phase configurations without neutral (delta), ask. 1. Positive photovoltaic input terminals. 2. Negative photovoltaic input...

Open the catalog to page 11
EQUINOX - 12

Range MODEL Base with adjustable feet for installing up to a maximum of 9 batteries + 1 BMS Monitoring module for EQX2 BATT batteries. Includes an internal 2.56 kWh lithium-ion battery 2.56 kWh lithium-ion battery with modular configuration, scalable up to 9 units + 1 BMS Batteries selection EQUINOX2 BATT BASE CODE DIMENSIONS WEIGHT RATED CAPACITY RATED VOLTAGE BATTERY CODE (F x AN x AL mm) (kWh) (V) (kg) For single-phase inverters, the maximum configuration is 1 x 6B2OP000015 + 1 x 6B2AC000001 + 8 x 6B2AC000002 For three-phase inverters ≤ 5 kW, the minimum configuration is 1 x 6B2OP000015...

Open the catalog to page 12

All SALICRU catalogs and technical brochures

  1. SPS NODE

    4 Pages

  2. SPS NET2

    2 Pages

  3. EQUINOX2 T

    4 Pages

  4. SLC ADAPT2

    4 Pages

  5. DC power S

    4 Pages

  6. DC power L

    4 Pages

  7. NS

    2 Pages

  8. EMi3

    4 Pages

  9. CV30-PV

    4 Pages

  10. SLC CUBE4

    4 Pages

  11. EQUINOX2 HT

    4 Pages

  12. RE3

    4 Pages

  13. CONTROLVIT

    32 Pages

  14. EQUINOX2 HSX

    4 Pages

  15. SLC ADAPT

    4 Pages

  16. SLC CUBE3+

    4 Pages

  17. VR EQX

    4 Pages

  18. CS IS

    2 Pages

  19. CV50

    4 Pages

  20. SPS ONE

    4 Pages

  21. CV30

    4 Pages

  22. CV10

    4 Pages

  23. ACV30-PV

    4 Pages

  24. Industry

    4 Pages

  25. SPS.ATS

    2 Pages

  26. SLC XPERT

    4 Pages

  27. SLC X-TRA

    4 Pages

  28. ARC

    2 Pages

  29. SPS HOME

    4 Pages

  30. SPS SOHO

    4 Pages

  31. SPS ADV R

    4 Pages

  32. SPS ADV T

    4 Pages

  33. SPS NET

    2 Pages

  34. SPS SAFE

    2 Pages

  35. CF CUBE3+

    4 Pages

  36. SPS PDU

    2 Pages

  37. SOFTWARE

    2 Pages

  38. BACS

    4 Pages

Archived catalogs

  1. ILUEST+ MT

    4 Pages

  2. IT M

    4 Pages

  3. EQUINOX S

    4 Pages

  4. EQUINOX TL

    4 Pages

  5. EQUINOX TM

    4 Pages

  6. ILUEST+ CR

    4 Pages

  7. SLC ADAPT

    2 Pages

  8. SLC TWIN PRO

    2 Pages

  9. FAC P

    2 Pages

  10. OPTIMUS

    2 Pages

  11. SLC ADAPT

    2 Pages

  12. RE brochure

    2 Pages