Catalog excerpts
U N I N T E R R U P T I B L E P O W E R S U P P L I E S ( U P S ) + L I G H T I N G F L O W D I M M E R S TA B I L I S E R S + V O LTA G E S TA B I L I S E R S & P O W E R L I N E C O N D I T I O N E R S + D C P O W E R S Y S T E M S + S TAT I C I N V E R T E R S + P H O T O V O LTA I C I N V E R T E R S EMi2 SERVOMOTOR VOLTAGE STABILISER EMi2: A great classic update Servomotor voltage stabilisers do have accumulated great experience, for they plenty year’s service in all of those appliances which a perfect voltage supply stabilisation is a must within complex critical loads: high start-up inrush currents, strongly reactive power behaviour, great power, etc. Notwithstanding and because of it, instead of disuse positioning, they do still enjoy prestige given to all dutyful industry appliances. Therefore SALICRU, faithful to its duty with quality electric supply, has chosen to review plus update such long lasting equipments. EMi2, as true afore series descending, keeping up high current handling capacity, a great stoutness for lasting overvoltages plus output voltag high accuracy (up to ±1%), overall forwarding a new facement, more compact and up to date. As improvements related to aforesaid range, they do have, series-built with toroidal self-transformers use for all power range, leading to a better performance plus response speed, having maintenance bypass and independent regulation per phase. PERFORMANCES Toroidal self-transformers for all power range, faster plus more efficient. Independent phase regulation as standard. Manual bypass as standard. Input regulation margins ±25% as standard. Output accuracy better than 1% (adjustable). Greater performance, up to 97%. High speed regulation, up to 80 V/sec. Control synoptic phase-independent with 7 segment display. Output digital amperimetre applyable within display. (1) Output voltage max-min protection. (1) Output stability guaranteed via thyristors servo-control. Relay interface. Null harmonic distortion. Simplified mechanical system, simpler maintenance. Overload tolerance up to 1000% nominal. Great reliability (great MTBF). Wide power range. Silent running. EMi2 Display for EMi2 (1) Optional APPLIANCES: Difficult loads always under control Within a great industrial process variety high sensitive voltage variation machinery is employed. Such loads, power-going and strongly reactive-wise, need to be supplied by voltage regulators able to meet such demands. Among others, we could name: milling cutters, grinders, machine-presses, lathes, polishers, electrical discharge machines, etc. as well as gearing and electric manouvering, numercial controls, electric ovens or telecom repeaters. VOLTAGE STABILISERS & POWER LINE CONDITIONERS
Open the catalog to page 12. Manouver switch Line-O-Regulator. R,S,T, input terminals (terminals + protec- U,V,W output terminals (terminals + pro- 5. Variacs magnetothermic protection. SALICRU's Other ■ Regulation speed comparison ► Output voltage max-min protection with ma- nual or automatic reload. ► Pre-Sales & After-Sales assessment service. ► Maintenance plus telemaintenance several SERVOMOTOR VOLTAGE STABILISER (1) Adjustable on demand (2) Optional Lexicon, dimensions and weights for models: 230 V 50 Hz input/output, independent phase regulation and 25% entry margins. Lexicon, dimensions and weights for...
Open the catalog to page 2All SALICRU catalogs and technical brochures
-
SPS NODE
4 Pages
-
SPS NET2
2 Pages
-
EQUINOX2 T
4 Pages
-
EQUINOX
20 Pages
-
SLC ADAPT2
4 Pages
-
SLC ADAPT / 2 catalogue
16 Pages
-
Rechargeable AGM battery
4 Pages
-
EQUINOX2 S/SX
4 Pages
-
DC power S
4 Pages
-
DC power L
4 Pages
-
NS
2 Pages
-
EMi3
4 Pages
-
CV30-PV
4 Pages
-
SLC CUBE4
4 Pages
-
EQUINOX2 HT
4 Pages
-
RE3
4 Pages
-
SLC CUBE4 Catalogue
16 Pages
-
CONTROLVIT
32 Pages
-
EQUINOX2 HSX
4 Pages
-
SLC ADAPT
4 Pages
-
SLC TWIN PRO2 0-3K
4 Pages
-
SLC CUBE3+
4 Pages
-
VR EQX
4 Pages
-
CS IS
2 Pages
-
CV50
4 Pages
-
SPS ONE
4 Pages
-
SALICRU General Catalogue
204 Pages
-
SLC TWIN RT3 4-10 kVA
4 Pages
-
SLC TWIN RT3 1-3 KVA
4 Pages
-
CV30
4 Pages
-
CV10
4 Pages
-
ACV30-PV
4 Pages
-
Homes, offices & shops
4 Pages
-
Industry
4 Pages
-
Infrastructures and energy
4 Pages
-
Telecominications
4 Pages
-
Energy and renewables
4 Pages
-
SLC TWIN PRO3 4-10 kVA
4 Pages
-
SPS.ATS
2 Pages
-
SLC TWIN RT2 LION
4 Pages
-
SLC XPERT
4 Pages
-
IT Transformers
2 Pages
-
SLC X-TRA
4 Pages
-
ARC
2 Pages
-
SPS HOME
4 Pages
-
SPS ADVANCE RT2
4 Pages
-
SPS SOHO
4 Pages
-
SPS ADV R
4 Pages
-
SPS ADV T
4 Pages
-
SPS NET
2 Pages
-
SPS SAFE
2 Pages
-
CF CUBE3+
4 Pages
-
SPS PDU
2 Pages
-
SOFTWARE
2 Pages
-
BACS
4 Pages
-
SLC XPERT catalogue
12 Pages
-
SLC CUBE3+ Catalogue
8 Pages
-
SLC X-TRA Catalogue
12 Pages
Archived catalogs
-
ILUEST+ MT
4 Pages
-
IT M
4 Pages
-
EQUINOX S
4 Pages
-
EQUINOX TL
4 Pages
-
EQUINOX TM
4 Pages
-
ILUEST+ CR
4 Pages
-
SLC TWIN RT2 0-3kVA
4 Pages
-
SLC TWIN PRO2 4-20kVA
4 Pages
-
SLC ADAPT
2 Pages
-
SLC TWIN PRO
2 Pages
-
FAC P
2 Pages
-
OPTIMUS
2 Pages
-
SLC ADAPT
2 Pages
-
ILUEST+ Catalogue
12 Pages
-
RE brochure
2 Pages
-
Brochure SLC CUBE3
2 Pages
-
Catalogue SLC-CUBE3
12 Pages