BM-R: Continuity of supply during maintenance operations Salicru’s BM-R series maintenance bypasses enable users to disconnect the Uninterrupted Power Supply (UPS) completely without interrupting the supply of power to the loads. They are essential for maintenance and repair work that, for reasons of safety, requires the elimination of any voltage present in the device. The BM-R series is available in current ratings of 16, 40 and 63 A, covering UPSs in the 0.7 to 10 kVA power range with single-phase input and output. The BM-R 63 A+ boasts exceptional functionality and, in combination with the SLC TWIN RT3 and SLC TWIN PRO3 ranges, offers two groups of programmable outputs (combining IEC C13 and C19 formats) and automatic battery detection, along with supports incorporating a rotating device that allows the BM-R to be lowered 90° without the need for disassembly when carrying out system maintenance. The 40 and 63 A models enable switching without passing through zero, thanks to an auxiliary contact that links them to the UPS (provided it has a digital signal port designed for this purpose) and allows them to turn the device on or not, as applicable. Performances ∙ Maintenance bypass in rack/wall format. ∙ Enables loads to operate during UPS maintenance or replacement. ∙ Simple operation via switch. ∙ Manual UPS-mains and mains-UPS switching. ∙ Easy installation and connection. ∙ Suitable for single-phase devices from 0.7 to 10 kVA. ∙ Inputs and outputs via IEC sockets for 16 A and 63 A+ models. ∙ Inputs and outputs via terminals for 40 A, 63 A and 63 A+ models. (1) ∙ Option to transfer from UPS to bypass. (2) ∙ Switching without passing through zero. (3) ∙ 2 groups of programmable outputs. (4) (1) For model 63 A+ also IEC outlets (2) For the 40 A, 63 A and 63 A+ models (3) Except the 16 A model (4) 63 A+ model, only in combination with the SLC TWIN PRO
Open the catalog to page 1REF JJ009C01 CODE 401AB000946 ED JANUARY 2023 - UNINTERRUPTIBLE POWER SUPPLY SYSTEMS (UPS) Technical specifications MODEL Rated voltage Information subject to change without notice. 1. IEC connections or output terminals . 4. Manual bypass signal auxiliary contact for signalling. 6. AC power supply IEC connector or input terminals. 8. Input and output terminals AC. 9. Input circuit breaker switch (6 and 10 kVA models only). Terminal strip to connect with the EBMS signal of the UPS. AVDA. DE LA SERRA 100 ■ 08460 PALAUTORDERA ■ SPAIN ■ [email protected]
Open the catalog to page 24 Pages
216 Pages
2 Pages
4 Pages
4 Pages
4 Pages
4 Pages
4 Pages
4 Pages
4 Pages
4 Pages
4 Pages
28 Pages
4 Pages
4 Pages
4 Pages
4 Pages
4 Pages
4 Pages
4 Pages
2 Pages
4 Pages
4 Pages
16 Pages
4 Pages
2 Pages
4 Pages
4 Pages
2 Pages
4 Pages
4 Pages
16 Pages
32 Pages
4 Pages
4 Pages
4 Pages
4 Pages
2 Pages
4 Pages
4 Pages
4 Pages
2 Pages
4 Pages
4 Pages
4 Pages
4 Pages
4 Pages
4 Pages
4 Pages
2 Pages
4 Pages
4 Pages
4 Pages
2 Pages
2 Pages
4 Pages
2 Pages
4 Pages
12 Pages
8 Pages
12 Pages
4 Pages
4 Pages
2 Pages
12 Pages
4 Pages
4 Pages
4 Pages
4 Pages
4 Pages
4 Pages
4 Pages
4 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
12 Pages