video corpo

Statement of Performance

Statement of Performance

Product catalog summary
Introduction
Furon® SSUM (Single Seal System) and DSUM (Dual Seal System) fittings are designed for use in FuseBond™ or welded installations of PFA pipe. These fittings were tested for maximum pressure resistance to evaluate their performance.

Design and Purpose
The Furon SSUM was originally rated for a maximum pressure of 300 PSI. The DSUM was developed to enhance safety and ease of installation, incorporating features like a locking tab and secondary sealing, while maintaining the sealing properties of the SSUM.

Vibration Test
Both SSUM and DSUM fittings were subjected to a vibration test using 2-inch Furon valves. The fittings were connected with a torque of 88.5 lbs/in and tested under 100 PSIG Clean Dry Air (CDA) while immersed in water to detect leaks. No leaks were observed after 48 hours of continuous vibration testing.

Maximum Pressure Test
The fittings were tested for pressure resistance by gradually increasing pressure from 0 PSIG to 310 PSIG in a controlled environment at 72°F. The SSUM fitting began to leak at 303 PSIG, while the DSUM fitting withstood the maximum test pressure of 310 PSIG without leakage.

Summary
Both fittings exceeded the typical pressure requirements for high purity chemical installations in the semiconductor industry, ensuring safety in chemical distribution systems. The DSUM fitting offers enhanced safety due to its higher pressure resistance and locking tab design.

Additional Test Conditions
- Vibration: 8200 VPM
- Inlet Pressure: 100 PSIG
- Valve Actuation Pressure: 70 PSIG
- Cycle Rate: 3 seconds on and 3 seconds off
- Temperature: 72°F +/-1

Note: The data was obtained under specific test conditions and may not reflect performance in other chemicals or systems.
See more

Catalog excerpts

Statement of Performance-1

VISIT PRODUCT PAGE FUR#N Pure Performance Statement of Performance Furon® Single & Dual Tongue & Groove Sealing Systems -Maximum Pressure Resistance Furon® SSUM (Single Seal System) and DSUM (Dual Seal System) fittings, generally used in a FuseBond™ or welded installation of PFA pipe, were tested side by side for maximum pressure resistance (Figure 1). When it was originally designed, Furon SSUM was rated for 300 PSI max pressure. Furon DSUM was developed based on the Furon SSUM concept and customer feedback on their experience with a Saint-Gobain No O-ring connector. The goal of the DSUM design was to provide additional safety (locking tab, secondary sealing, etc...), help the installation process and offer the same sealing properties as the SSUM design. Vibration Test In this analysis, Furon 2-inch valves were used to test the efficiency and reliability of both the Furon SSUM and Furon DSUM fittings in a complex environment. A tight 88.5 lbs/ in torque connection was applied before tabs were set into position. Then the connections were plugged into 100 PSIG Clean Dry Air (CDA) and immersed in water to monitor any bubbles created during a one minute period. If a single bubble was created during this time, the product was rejected. The components were then installed on a vibrating bench and the Furon valves were cycled in order to increase stress on the connections. Figure 1 - Vibration Test Additional test conditions included: • Vibration: 8200 VPM • Inlet Pressure: 100 PSIG • Valve Actuation Pressure: 70 PSIG • Cycle Rate: 3 seconds on and 3 seconds off • Temperature: 72°F +/-1 After 48 hours of continuous testing, the components were removed from the vibration unit and subjected to the bubble test again. No bubbles appear during the one minute test period for either the SSUM or DSUM fitting design. Maximum Pressure Test For this analysis, the Furon SSUM and DSUM fittings were connected to a liquid pumping system, allowing a slow but consistent pressure increase starting at 0 PSIG up to 310 PSIG. The test was performed in a controlled environment at 72°F +/-1 . The SSUM system performed in agreement with the product properties (max pressure 300 PSIG) and leakage started to occur at 303 PSIG. The DSUM system was brought to the system test limit (310 PSIG) without suffering any leakage. Summary Both Furon SSUM and DSUM connections achieved 300 PSIG, which far exceeds any pressure normally encountered in a high purity chemical installation in the semiconductor industry. Thus the use of either fitting allows for ample safety on any chemical distribution system found in a fab environment. The test also highlights that the Furon DSUM fitting offers an even higher level of safety thanks to its high pressure resistance and its locking tab system design. The data provided here was obtained under defined test conditions. The tests were designed to mimic use or worst case conditions. However, Saint-Gobain Performance Plastics makes no specific claims about the performance of the components in other chemicals or systems. FLS-6323-0818-SGPS ©2018 Saint-Gobain Performance Plastics

 Open the catalog to page 1

All Saint-Gobain Performance Plastics - Process System catalogs and technical brochures

  1. Tygon® XL-60

    2  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.