Product catalog summary
Overview: The TAS.OP laminar flow system is designed for operating theatres, providing vertical unidirectional airflow suitable for ISO 5 to ISO 8 class operating rooms as per ISO 14644 standards. It emphasizes the importance of proper return grille positioning to enhance indoor air quality.
Features:
  • Applicable for critical surgeries in ISO 5 class and light surgeries in ISO 7 or ISO 8 class.
  • Constructed with AISI 304 stainless steel for easy cleaning and disinfection.
  • Equipped with H14 HEPA filters, tested and packaged in a controlled environment.
  • Perforated panel diffusers are removable for quick access to filters.
Technical Data:
  • The system includes a stainless steel plenum with air inlets designed for optimal air distribution.
  • HEPA filters have 99.995% MPPS H14 efficiency, tested individually with an optical particle counter.
  • Design air flow rates are specified for various nominal sizes, with and without surgical light settings.
Testing and Validation:
  • Includes ports for easy testing of HEPA filter pressure drop and leakage tests.
  • Room validation is possible after leakage tests and cleaning, ensuring compliance with ISO class requirements.
Air Exhausting and Ventilation:
  • Recommends exhausting 65-70% of air from floor level and the remainder from high wall grilles to improve ventilation effectiveness.
  • Exhaust grilles are designed for easy cleaning and can be equipped with G4 and F9 filters.
Technical Advice:
  • Recirculation systems are advised to maintain cleanliness and reduce energy consumption, with options for dedicated or built-in systems.
Tender Text:
  • The system is designed for clean air supply in operating rooms, aiding in contamination control and temperature regulation.
  • HEPA filters are protected by aluminum grids and feature a seamless gasket to prevent air leakage.
  • Options include reverse liquid seal technology and fabric laminators for enhanced air velocity control.
Manufacturer Information: SagiCofi m S.p.A., based in Milan, Italy, reserves the right to modify product features without notice.
See more

Catalog excerpts

TAS.OP-1

TAS.OP Laminar flow system for Operating Theatres Ecoefficiency for Indoor Air Quality

 Open the catalog to page 1
TAS.OP-2

Laminar flow system for Operating Theatres TAS.OP Filtration SagiCofim Air filtration and distribution system for operating theatres, with vertical unidirectional air flow, suitable for operating rooms from ISO 5 to ISO 8 class, according to ISO 14644. A proper return grilles positioning is recommended to obtain the highest indoor air quality level in the whole room. H14 HEPA filters manufactured, tested and packaged in controlled clean environment Advantages Suitable to operating theatres for critical surgery in ISO 5 class and for light surgery in ISO 7 or ISO 8 class, according to ISO...

 Open the catalog to page 2
TAS.OP-3

Laminar flow system for Operating Theatres TAS.OP SagiCofim Structure The distribution plenum is in stainless steel AISI 304 with one or two side air inlets, whose size is designed to have a maximum air inlet velocity of 3-4 m/s for a proper air distribution inside the plenum itself. According the ceiling size, the plenum can be supplied in one or two parts to be assembled on site. Filters holding frame in stainless steel AISI 304 to avoid any risk of corrosion, ensuring the perfect planarity and air tightness for the whole system’s life. The perforated diffuser, also made of AISI 304 stainless...

 Open the catalog to page 3
TAS.OP-4

Laminar flow system for Operating Theatres TAS.OP SagiCofim Air flow rate vs air velocity design TAS.OP laminar flow system suits all the most used International Standards. In the following table the design air flow rate to achieve the minimum required air velocities according to the design Standards or Guidelines TAS.OP Design air flow rate [m3/h] Testing and validation Two dedicated ports are factory mounted to make all the testing and validation procedures as easy as possible. • HEPA filters pressure drop: a good filtration directly into the AHUs (typically G4 + F9 + H13) is required to make...

 Open the catalog to page 4
TAS.OP-5

Laminar flow system for Operating Theatres TAS.OP Technical data Air exhausting and ventilation effectiveness It is recommended to exhaust 6570% of the total air flow from the floor level and, the balance, from the highest part of the walls, by installing four grilles in the lower part and four smaller grilles on the upper part of the walls. By following this rule, the overall ventilation effectiveness would be improved, helping the supply air flowing from the ceiling to the exhaust grilles to keep a stable and uniform direction, from the surgical table to the walls, protecting the patient and effectively...

 Open the catalog to page 5
TAS.OP-6

Laminar flow system for Operating Theatres TAS.OP SagiCofim The air recirculation can be designed in two different ways: Recirculation To reach and maintain the proper cleanliness class (typically ISO 5 according to ISO 14644) and to keep the CFUs concentration below the requested level (typically 5-10 CFU/m3) in operational, a big amount of air is needed. To achieve the proper air quality inside the operating theatres and, at the same time, to reduce the energy consumption for cooling/ heating the total air volume, the most used solution is to have a minimum amount of fresh air and then a dedicated...

 Open the catalog to page 6
TAS.OP-7

Laminar flow system for Operating Theatres TAS.OP Technical advice 2. One or more makeup air AHUs to supply the total needed amount of fresh air to all the operating rooms and a “built-in” recirculation system above the false ceiling and directly connected to the filtering ceiling plenu

 Open the catalog to page 7
TAS.OP-8

Laminar flow system for Operating Theatres TAS.OP Filtration SagiCofim Tender text TAS-OP Plenum-type laminar flow-style diffuser for clean air supply in operating rooms. The air, duly filtered through H14 HEPA filters, will play a major role in: • Airborne contamination dilution • Moving contaminants from cleaner to less clean areas, reducing the risk of contamination over the surgical table • Temperature and humidity control • Dilution and removal of waste anesthetic gases The structure is totally made of AISI 304 stainless steel, for easy cleaning and corrosion-free long operating life The...

 Open the catalog to page 8

All SagiCofim catalogs and technical brochures

  1. PV

    2  Pages

  2. INDUL V45

    3  Pages

  3. BPV - VENL0001

    16  Pages

  4. DUG-B -DUG-A

    2  Pages

  5. LBM - KBM

    1  Page

  6. LLB - KK

    1  Page

  7. AB - AA

    3  Pages

  8. LS - KS

    1  Page

  9. DEC A -DEC S

    3  Pages

  10. Pharmasafe

    8  Pages

  11. AH - AS

    1  Page

  12. CB-CA

    1  Page

  13. AF 981 I

    1  Page

  14. LT 151

    2  Pages

  15. LT 500

    3  Pages

  16. LT 350

    3  Pages

  17. BE

    2  Pages

  18. WS 400

    1  Page

  19. WT

    2  Pages

  20. EE 400

    2  Pages

  21. ZAR-R

    1  Page

  22. AF 350

    2  Pages

  23. AD 780

    2  Pages

  24. DR 160

    1  Page

  25. CAT-C

    1  Page

  26. SPIN-C

    1  Page

  27. WR

    2  Pages

  28. WR 400

    1  Page

  29. TAB

    4  Pages

  30. ZAR-C

    1  Page

  31. WT 500 S

    1  Page

  32. CC 600

    1  Page

  33. SDFZ

    1  Page

  34. DC 560 T

    1  Page

  35. DC 560 S

    1  Page

  36. DC 570 S

    1  Page

  37. DC 570 T

    1  Page

  38. SDFZ-R

    1  Page

  39. LD 600

    3  Pages

  40. KMF

    8  Pages

  41. RSVC-K

    4  Pages

  42. RSVB

    16  Pages

  43. RSVC

    16  Pages

  44. RSVQ

    12  Pages

  45. VRK

    1  Page

  46. VRRK

    1  Page

  47. GTA 010 EN

    12  Pages

  48. GT 019

    12  Pages

  49. GT 018

    12  Pages

  50. GT 050

    12  Pages

  51. GT 015

    12  Pages

  52. GTE 11

    12  Pages

  53. GTE 05

    12  Pages

  54. GTE 06

    12  Pages

  55. GTE 10

    12  Pages

  56. GTE 08

    12  Pages

  57. GTA 010

    12  Pages

  58. GTA 015

    12  Pages

  59. SDL-SDLT

    16  Pages

  60. HTE 400

    14  Pages

  61. SFD-SFDT

    16  Pages

  62. TB-TC

    1  Page

  63. AFO-AL1-AL2

    3  Pages

  64. SA SA - LF

    2  Pages

  65. MCA - MCPA

    4  Pages

  66. RAS

    12  Pages

  67. INER-ST

    8  Pages

  68. AD 300

    2  Pages

  69. GS 130

    1  Page

  70. GF 130

    2  Pages

  71. PDP

    1  Page

  72. MPS

    2  Pages

  73. PK

    3  Pages

  74. JD

    3  Pages

  75. FLG

    2  Pages

  76. PFA/4/5

    1  Page

  77. PFO/E/S/H

    1  Page

  78. PFO/6/7/8/9

    1  Page

  79. CARBO

    1  Page

  80. CANISTER

    4  Pages

  81. Multimod

    1  Page

  82. CAB

    1  Page

  83. Modulo

    1  Page

  84. CT

    1  Page

  85. SAF

    1  Page

  86. CAB - PT

    1  Page

  87. DAB - DAA

    1  Page

  88. ABH - AAH

    1  Page

  89. LLMB - KKMB

    1  Page

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.