video corpo

SDL-SDLT
1 /16Pages

SDL-SDLT

SDL-SDLT
1 /16Pages

Catalog excerpts

SDL-SDLT-1

SDL - SDLT Shut-off - Gas Shut-off Damper

 Open the catalog to page 1
SDL-SDLT-2

Shut-off - Gas Shut-off Damper Marine - Oil & Gas Industry Quality Our Quality Management System has been certified in accordance with the standard ISO 9001 : 2008. Our company is monitored by RINA, a member of iQNet European network, and is appointed with the quality management system certificate for the fields of activity of design and production of filter, filter systems and air distribution components for HVAC systems. Environment Being involved with the production of equipment for indoor environment control and air filtration, it is natural for SagiCofim to consider the environment protection...

 Open the catalog to page 2
SDL-SDLT-3

Shut-off - Gas Shut-off Damper SagiCofim SDL - SDLT Shut-off and Gas Shut-off Dampers are used to stop the air flow or to let the passage of the air within ductworks or behind air intake grilles for ships and offshore installation. They can be required for safety reasons as a fire protection component as they isolate or open sections of air conditioning or ventilation systems in case of fire and gas on board. Shut-off and Gas Shut-off Dampers are available with remote electrical or pneumatic rotating actuators or with manual command, both standard or ATEX version. If fitted with an automatic...

 Open the catalog to page 3
SDL-SDLT-4

Shut-off - Gas Shut-off Damper SagiCofim SDL -SDLT 0 dimensions in [mm] General features Shut-off dampers & Gas Shut-off dampers * Dampers can be supplied on request with special dimensions by multiple welded arrangement. With manual control With electrical control

 Open the catalog to page 4
SDL-SDLT-5

Shut-off - Gas Shut-off Damper Marine - Oil & Gas Industry SagiCofilTI Damper operating range: ATEX area - 20 ° C ^ t s + 50 ° C - Vmax 15 m/s - Pmax 3000 PaSAFE area - 20 ° C ^ t ^ + 70 ° C - Vmax 25 m/s - Pmax 3000 Pa Damper components materials Silicone seals and thin blades only for models SDLT

 Open the catalog to page 5
SDL-SDLT-6

Shut-off - Gas Shut-off Damper SagiCof’ im Dimensions of flanges and drilling 4- Fixed holes at corner o Intermediate holes

 Open the catalog to page 6
SDL-SDLT-7

Shut-off - Gas Shut-off Damper SagiCofim Damper weights [Kg] Damper weights [Kg] H W [width] Average values valid for all standard types (approx. ± 5%) Values in the table refer to the standard material manufcturing types. Different material manufacturing does not have significant variance to the above mentioned values. Controls and actuators weights are not included.

 Open the catalog to page 7
SDL-SDLT-8

Shut-off - Gas Shut-off Damper SagiCofim Torque requirements (Nm) for actuating systems selection Damper torque Note: for SDL model, actual required torque value can be up to 20% lower than the above mentioned values.

 Open the catalog to page 8
SDL-SDLT-9

Shut-off - Gas Shut-off Damper SDL - SDLT Performances Pressure drop and noise level 55 • Max noise level: 60 dB(A) • Standard pressure drop: 6 Pa With damper fully open and air speed of 5 m/s at maximum rate. With damper fully open and air speed of 15 m/s at maximum rate. SDLT gas leakage according to EN1751 10000 Leakage test across closed blades Positive pressure Negative pressure Leakage test for casing Positive pressure

 Open the catalog to page 9
SDL-SDLT-10

Shut-off - Gas Shut-off Damper SagiCofim Damper controls Type E Electrical actuator Type X Electrical ATEX zone approved actuator Shut-off dampers and Gas Shutoff dampers can be provided with many different combinations of actuators - junction boxes - limit switches in order to fulfil to all technical specification or customer demand: nominal actuator torque (5, 10, 15, 30 ... Nm); voltage input range from 24V to 230 V AC/DC; plastic, painted aluminium, galvanized steel or AISI 316 actuator case; on/off, on/off spring return, modulating actuator with or without integrated micro switches, SPDT...

 Open the catalog to page 10
SDL-SDLT-11

Shut-off - Gas Shut-off Damper SagiCofim Type of installation * Actuator protrusion only. For total protrusion, please consider also plate protrusion. Electric actuators are fixed to levers protection carter by an universal plate (galvanized steel or AISI 316). This plate is designed to fix different type of actuators only switching its own orientation or using different fixing holes. Different type of installation: • BFL type through fixing holes 3, with a 180° plate rotation respect to plate position as shown in the example; • LF / BFN type through fixing holes 4, with a 180° plate rotation...

 Open the catalog to page 11
SDL-SDLT-12

Shut-off - Gas Shut-off Damper SDL - SDLT Damper controls Type P Pneumatic actuator SDL - SDLT Shut-off dampers and Gas Shut-off dampers can be equipped with rotating pneumatic actuators (6 - 10 bar) and additional accessories such as solenoid valves and limit switches (mechanical, magnetic or inductive type). Actuator can be made of PTFE coated aluminium, painted steel, stainless steel or composite. Fail CLOSE A typical pneumatic system is composed by: • a rotating piston with a specific even number of springs (according to the model); • a 3 - ways solenoid valve; • a manometer and a pressure...

 Open the catalog to page 12
SDL-SDLT-13

Shut-off - Gas Shut-off Damper Marine - Oil & Gas Industry SdgiCoflVTI * Piston available in 3 sizes 15 Nm - 43 Nm - 132 Nm * Piston available in 3 sizes 15 Nm - 43 Nm - 132 Nm Both available for ATEX version. Custom configuration available. Extra and accessories • Check valve • In line filter • Manual by-pass valve • Heating cable • Manual override with detachable clutch

 Open the catalog to page 13
SDL-SDLT-14

Shut-off - Gas Shut-off Damper SagiCofim Damper controls Type C 22 - Manual drive This damper version is provided with a control handle (C22). SDL or SDLT + C22 can be used also as a balancing damper; in fact the handle can be fixed in all different positions from fully open to fully closed. A safety clamp blocks the handle in the selected position. Maintenance procedures Mechanical couplings and electrical connections are tested before shipping. Maintenance cadence depends by the dampers features (material) and the location where they are installed (fresh air inlet or exhaust duct) During the...

 Open the catalog to page 14
SDL-SDLT-15

Shut-off - Gas Shut-off Damper Marine - Oil & Gas Industry SagiCofilTI References Shipyards Barreras (Spain) Cantieri Apuania (Italy) Ferrol (Spain) Fincantieri (Italy) Flender Werft (Germany) Jurong (Singapore) Keppel Fels (Singapore) Lloyd Werft (Germany) Meyer Werft (Germany) Navantia (Spain) Rosetti Marino (Italy) Sembawang (Singapore) SMOE (Singapore) STX France (France) T. Mariotti (Italy) Owners Carnival Corsica Ferries Costa Crociere Cunard Finnlines Grimaldi Group Holland America Line Marina Militare Italiana Minoan Lines Norwegian Cruise Line P&O Radisson Seven Seas Renaissance...

 Open the catalog to page 15

All SagiCofim catalogs and technical brochures

  1. PV

    2  Pages

  2. INDUL V45

    3  Pages

  3. BPV - VENL0001

    16  Pages

  4. DUG-B -DUG-A

    2  Pages

  5. LBM - KBM

    1  Page

  6. LLB - KK

    1  Page

  7. AB - AA

    3  Pages

  8. LS - KS

    1  Page

  9. DEC A -DEC S

    3  Pages

  10. TAS.OP

    8  Pages

  11. Pharmasafe

    8  Pages

  12. AH - AS

    1  Page

  13. CB-CA

    1  Page

  14. AF 981 I

    1  Page

  15. LT 151

    2  Pages

  16. LT 500

    3  Pages

  17. LT 350

    3  Pages

  18. BE

    2  Pages

  19. WS 400

    1  Page

  20. WT

    2  Pages

  21. EE 400

    2  Pages

  22. ZAR-R

    1  Page

  23. AF 350

    2  Pages

  24. AD 780

    2  Pages

  25. DR 160

    1  Page

  26. CAT-C

    1  Page

  27. SPIN-C

    1  Page

  28. WR

    2  Pages

  29. WR 400

    1  Page

  30. TAB

    4  Pages

  31. ZAR-C

    1  Page

  32. WT 500 S

    1  Page

  33. CC 600

    1  Page

  34. SDFZ

    1  Page

  35. DC 560 T

    1  Page

  36. DC 560 S

    1  Page

  37. DC 570 S

    1  Page

  38. DC 570 T

    1  Page

  39. SDFZ-R

    1  Page

  40. LD 600

    3  Pages

  41. KMF

    8  Pages

  42. RSVC-K

    4  Pages

  43. RSVB

    16  Pages

  44. RSVC

    16  Pages

  45. RSVQ

    12  Pages

  46. VRK

    1  Page

  47. VRRK

    1  Page

  48. GTA 010 EN

    12  Pages

  49. GT 019

    12  Pages

  50. GT 018

    12  Pages

  51. GT 050

    12  Pages

  52. GT 015

    12  Pages

  53. GTE 11

    12  Pages

  54. GTE 05

    12  Pages

  55. GTE 06

    12  Pages

  56. GTE 10

    12  Pages

  57. GTE 08

    12  Pages

  58. GTA 010

    12  Pages

  59. GTA 015

    12  Pages

  60. HTE 400

    14  Pages

  61. SFD-SFDT

    16  Pages

  62. TB-TC

    1  Page

  63. AFO-AL1-AL2

    3  Pages

  64. SA SA - LF

    2  Pages

  65. MCA - MCPA

    4  Pages

  66. RAS

    12  Pages

  67. INER-ST

    8  Pages

  68. AD 300

    2  Pages

  69. GS 130

    1  Page

  70. GF 130

    2  Pages

  71. PDP

    1  Page

  72. MPS

    2  Pages

  73. PK

    3  Pages

  74. JD

    3  Pages

  75. FLG

    2  Pages

  76. PFA/4/5

    1  Page

  77. PFO/E/S/H

    1  Page

  78. PFO/6/7/8/9

    1  Page

  79. CARBO

    1  Page

  80. CANISTER

    4  Pages

  81. Multimod

    1  Page

  82. CAB

    1  Page

  83. Modulo

    1  Page

  84. CT

    1  Page

  85. SAF

    1  Page

  86. CAB - PT

    1  Page

  87. DAB - DAA

    1  Page

  88. ABH - AAH

    1  Page

  89. LLMB - KKMB

    1  Page

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.