RSVQ-1

RSVQ 9 lar Term>nal Units SagiCofim Ecoefficiency for Indoor Air Quality

 Open the catalog to page 1
RSVQ-2

VAV Rectangular Terminal Units SagiCofim Variable Air Volume (VAV) HVAC systems are the best solution to guarantee high levels of comfort and energy efficiency in civil and industrial applications. VAV systems are well suited for the climate control of modern office buildings, with extensive glass facades and variable occupancy levels which cause uneven cooling loads profiles, with relevant values even in the winter season. For industrial process applications, such as research laboratories, the use of VAV systems allows to maintain the required differential pressure levels between adjacent rooms together...

 Open the catalog to page 2
RSVQ-3

VAV Rectangular Terminal Units insulated or not insulated Comfort SagiCofim RSVQ10 N1 - RSVQ10 I1 Construction Casing in galvanized steel Z 200 Air flow measurement device in extruded aluminium with average APd detection chamber Control blades in heavy extruded aluminium with opposed movement and sealing gaskets Control measurement range (0) 2...12 m/s Air flow control blade with air tightness class 4 EN 1751 Casing with air tightness class C EN 1751 Working pressure 30.1000 Pa Connection flanges 36 mm with 9 mm holes Actuator with pressure sensor and VAV-Compact controller type LMV D3 MP...

 Open the catalog to page 3
RSVQ-4

VAV Rectangular Terminal Units SagiCofim Acoustic and air flow data Table 2 Avearge correction for other dimensions B, dB (A) Base mm 200 300 400 500 700 800 900 1000 1100 1200 Table 3 Average pressure drop for all dimensions - open blade V (m/s) 2 4 6 8 10 12

 Open the catalog to page 4
RSVQ-5

VAV Rectangular Terminal Units RSVQ Electrical data Connections to safety transformer 1 LMV-D2-MP SG Technical data • Supply voltage 24 V AC / DC • Power consumption 2,5 W / 5 VA (max 5 A @ 5 ms) • Cable connection 1 m, 4 x 0,75 mm2 • Protection class III love voltage • Protection class IP54 • EMC CE according to 89/336 EEC Feedback signal U5 / MP-bus The U5 terminal provides a constant feedback of the actual air flow and is also the digital communication terminal with MP accessories. It is important to bring it on the control panel for operation data and functions re-programming. Notes for PP...

 Open the catalog to page 5
RSVQ-6

Rectangular sound attenuators for VAV Terminal Units SagiCofim Construction Casing in galvanized steel Connection flanges with holes Splitters with glass wool insulation for high attenuation performances, protected with laminated non-woven glass fabric against abrasion, with aerodynamic profile for low pressure drop and low self-regenerated noise levels Modular construction with plenum 300 mm + splitters standard length 1200 mm Special version RSVQS / LF With sound attenuation splitters, protected by perforated sheet Special version RSVQS / HOSP With sound attenuation splitters, protected by...

 Open the catalog to page 6
RSVQ-7

Hot water reheat coils RSVQH Installation Construction Standard version 2 rows, with copper tubes 16,5 mm Aluminium fins, tk. 0,13, threaded connections Casing in galvanized steel 15 / 10 with air-tight sealing Perforated flanges Version with 40 tube pitch (for low temp. hot water) Version with 60 tube pitch (for high temp. hot water) Pressure test at 2 MPa (20 bar) Data for selection and sizing Required power = kW Inlet air temp. = °C Inlet water temp. = °C Outlet water temp. = °C Providing the data a specific technical sheet will be developed complete with dimensions, performance...

 Open the catalog to page 7
RSVQ-8

VAV Rectangular Terminal Units Application examples VAV - Compact for stand-alone applications Individual room comfort + • Wide range of potential applications • Adjustable to each application • Demand-based single-room application • Operation with Fan Optimiser Active / passive sensor Room temperature control panel VAV - Compact with bus connection and sensor integration Interface MP Intelligent simplicity • System connection to DDC controller with MP interface via MP-bus ® • Integration in higher-level systems such as LONWORKS ®, Konnex. Ethernet TCP/IP, Profibus DP, etc. via MP gateway • Convenient,...

 Open the catalog to page 8
RSVQ-9

VAV Rectangular Terminal Units Application examples Parallel control for air supply and return Operation principle 1 The control signal is sent both to the Master and to the Slave controller which have the Vmin and Vmax set point. 2 The difference between the Master and the Slave air flow has the same absolute value on the whole control range. Air flow value measurement signal Es. 0...10V To maintain: positive room pressure = Supply > Return negative room pressure = Supply < Return Constant difference between supply and return Supply Room MASTER / SLAVE control Operation principle 1 The control...

 Open the catalog to page 9
RSVQ-10

VAV Rectangular Terminal Units SagiCofim Technical specifications VAV rectangular terminal unit, type RSVQ 10 N1 • Pressure independent for VAV/ CAV HVAC systems • Galvanized steel casing, tk. 1 mm, length 400 mm • Control blades in heavy extruded aluminium with aerodynamic profile and sealing gaskets • Opposed movement transmission with toothed wheels, external mounted to air flow • Blade tightness class 4 according to EN ISO 1751 • Casing tightness class C according to EN ISO 1751 • Velocity control range (0) 2.. .12 m/s Acoustic data tested according to EN ISO 5135 : 2003 • Connection flanges...

 Open the catalog to page 10
RSVQ-11

VAV Rectangular Terminal Units RSVQ How to order Rectangular terminal units Control signal A 0 ÷ 10 V B 2 ÷ 10 V C Changeable D MP . . V max % V nom . . V min % V nom 1 Galvanized steel 2 Stainless Steel AISI 304 N Non insulated version I Insulated version VAV rectangular terminal unit 400 x 310, equipped with LMV D3 MP SG, galvanized steel casing, with glass wool insulation; Department = 0,4 x 0,3 = 0,12 m2 . V nom = 12 (m/s) x 0,12 (S). x 3600 (s) = 5184 m3/h . V min = 50% (2592 m3/h); V max 80% (4147 m3/h) . V max can be set inside a range 40 ÷ 100% . of V nom . . V min can be set to a value...

 Open the catalog to page 11
RSVQ-12

SagiCofim spa Comfort Filtration Engineering Sagicofim S.p.A. reserves the right to change or modify product features and specifications at any moment, without prior notice. via Firenze 1 20063 Cernusco sul Naviglio Milano Italy tel +39 02 929021 r.a. fax +39 02 92902300 info@sagicofim.com www.sagic

 Open the catalog to page 12

All SagiCofim catalogs and technical brochures

  1. PV

    2  Pages

  2. INDUL V45

    3  Pages

  3. BPV - VENL0001

    16  Pages

  4. DUG-B -DUG-A

    2  Pages

  5. LBM - KBM

    1  Page

  6. LLB - KK

    1  Page

  7. AB - AA

    3  Pages

  8. LS - KS

    1  Page

  9. DEC A -DEC S

    3  Pages

  10. TAS.OP

    8  Pages

  11. Pharmasafe

    8  Pages

  12. AH - AS

    1  Page

  13. CB-CA

    1  Page

  14. AF 981 I

    1  Page

  15. LT 151

    2  Pages

  16. LT 500

    3  Pages

  17. LT 350

    3  Pages

  18. BE

    2  Pages

  19. WS 400

    1  Page

  20. WT

    2  Pages

  21. EE 400

    2  Pages

  22. ZAR-R

    1  Page

  23. AF 350

    2  Pages

  24. AD 780

    2  Pages

  25. DR 160

    1  Page

  26. CAT-C

    1  Page

  27. SPIN-C

    1  Page

  28. WR

    2  Pages

  29. WR 400

    1  Page

  30. TAB

    4  Pages

  31. ZAR-C

    1  Page

  32. WT 500 S

    1  Page

  33. CC 600

    1  Page

  34. SDFZ

    1  Page

  35. DC 560 T

    1  Page

  36. DC 560 S

    1  Page

  37. DC 570 S

    1  Page

  38. DC 570 T

    1  Page

  39. SDFZ-R

    1  Page

  40. LD 600

    3  Pages

  41. KMF

    8  Pages

  42. RSVC-K

    4  Pages

  43. RSVB

    16  Pages

  44. RSVC

    16  Pages

  45. VRK

    1  Page

  46. VRRK

    1  Page

  47. GTA 010 EN

    12  Pages

  48. GT 019

    12  Pages

  49. GT 018

    12  Pages

  50. GT 050

    12  Pages

  51. GT 015

    12  Pages

  52. GTE 11

    12  Pages

  53. GTE 05

    12  Pages

  54. GTE 06

    12  Pages

  55. GTE 10

    12  Pages

  56. GTE 08

    12  Pages

  57. GTA 010

    12  Pages

  58. GTA 015

    12  Pages

  59. SDL-SDLT

    16  Pages

  60. HTE 400

    14  Pages

  61. SFD-SFDT

    16  Pages

  62. TB-TC

    1  Page

  63. AFO-AL1-AL2

    3  Pages

  64. SA SA - LF

    2  Pages

  65. MCA - MCPA

    4  Pages

  66. RAS

    12  Pages

  67. INER-ST

    8  Pages

  68. AD 300

    2  Pages

  69. GS 130

    1  Page

  70. GF 130

    2  Pages

  71. PDP

    1  Page

  72. MPS

    2  Pages

  73. PK

    3  Pages

  74. JD

    3  Pages

  75. FLG

    2  Pages

  76. PFA/4/5

    1  Page

  77. PFO/E/S/H

    1  Page

  78. PFO/6/7/8/9

    1  Page

  79. CARBO

    1  Page

  80. CANISTER

    4  Pages

  81. Multimod

    1  Page

  82. CAB

    1  Page

  83. Modulo

    1  Page

  84. CT

    1  Page

  85. SAF

    1  Page

  86. CAB - PT

    1  Page

  87. DAB - DAA

    1  Page

  88. ABH - AAH

    1  Page

  89. LLMB - KKMB

    1  Page

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.